Explosives detection in soil using a field-portable continuous flow immunosensor.

A field method for quantitative analysis of explosives in contaminated soil samples is described. The method is based on a displacement immunoassay performed in a commercial instrument, the FAST 2000, engineered by Research International Inc. The method can be used on-site to measure 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) within 5min. For this study, replicate analyses were performed on soil extracts prepared from each field sample as well as appropriate controls, blanks, and laboratory standards. Statistical analyses were done to assess accuracy, bias, and predictability of the method. The results demonstrated that the immunosensor could be used effectively to screen environmental samples for the presence or absence of explosives. In most samples, the method also provided quantitative values that were in good agreement with standard laboratory analyses using HPLC. A limited number of sample matrices interfered with the immunoassay and produced results that varied significantly from the laboratory data. In each case, the compounds causing the problem have been identified and efforts are being made to minimize these matrix interferences in future field evaluations.

Chromatography, High Pressure Liquid↗

Regeneration of immobilized antibodies on fiber optic probes.

The regeneration of antibodies covalently immobilized to an optical fibre surface was investigated by dissociation of the antibody-antigen complex with three different solvents: (a) an acidic solution (0.1 M glycine hydrochloride in 50% (v/v) ethylene glycol, pH 1.75), (b) a basic solution (0.05 M tetraethylamine in 50% (v/v) ethylene glycol, pH 11.0) and (c) 50% (v/v) ethanol in PBS. The fibres coated with polyclonal rabbit anti-goat antibody against a large protein retained 70% and 65% of the original signal after five consecutive regenerations with acidic and basic solvent systems, respectively. The fibres coated with monoclonal mouse anti-trinitrobenzene antibody specific for a small organic molecule, retained over 90% of the original signal when regenerated with basic and ethanol solutions. This study evaluated regeneration and reuse of antibody-coated fibre optic biosensors as a means of reducing routine laboratory analysis costs and time.

Animals↗