PubMed Health⌕ Search

Biomedical subjects

L Sterns

Publications and source records attributed to L Sterns.

4 recordsLinked to original sources

New ICD-technologies: first clinical experience with dual-chamber sensing for differentiation of supraventricular tachyarrhythmias.

Inappropriate ICD therapy for supraventricular arrhythmias remains an unsolved problem and may lead to serious clinical situations. Current algorithms for differentiation of supraventricular and ventricular arrhythmias are based on ventricular sensing solely and, therefore, lack sensitivity and specificity. This preliminary analysis from a multicenter trial comprises data from the first 26 patients who received a Res-Q Micron active-can ICD (Sulzer Intermedics) with a ventricular defibrillation lead and an additional bipolar lead for atrial sensing. Digitized atrial and ventricular waveform storage as well as interval charts from 102 induced and 30 spontaneous arrhythmia episodes were prospectively collected and analyzed with regard to appropriateness of ICD therapy. From all 132 arrhythmia episodes, high-quality stored dual-chamber intracardiac electrograms (IEGM) could be retrieved for further analysis: in 40 (30%) episodes, atrial fibrillation (AF with rapid ventricular response 22, AF with VT 9, AF with VF 9) was identified as the underlying intrinsic rhythm, and inappropriate ICD therapy was delivered in 4/22 (18%) episodes of AF with rapid ventricular response. In the remaining 92 (70%) episodes, sinus rhythm was the underlying atrial rhythm (SR with VT 13, SR with VF 79), and no inappropriate therapy was observed. Three of 22 (15%) high-energy shocks delivered for ventricular arrhythmias (VT 9, VF 9, rapid AF 4) terminated AF at the same time. In total, there were 3 complications (2 atrial lead dislodgments, 1 revision for bleeding). Both atrial lead dislodgments occurred in the 2 patients with passive-fixation leads compared to none in the 24 patients with active-fixation leads (p = 0.003). In conclusion, dual-chamber sensing and waveform storage of the new Res-Q Micron offer very helpful diagnostic tools for the detection of inappropriate ICD-therapy. Placement of an additional atrial lead is safe and does not interfere with proper ICD function. However, for avoidance of atrial lead dislodgment, active fixation leads are recommended. With the tested active-can lead configuration, the efficacy of successful atrial cardioversion by high-energy shocks delivered for ventricular arrhythmias seems to be low.

Algorithms↗

[The implantable cardioverter/defibrillator (ICD). Developments up to the present time and future perspectives].

The implantable cardioverter/defibrillator is gaining increasing significance in the therapy of life-threatening ventricular arrhythmias. Independently, the team of Mirowski and the team of Schuder started to develop experimental automatic implantable defibrillators in the seventies. In 1980, the first human implant of an automatic defibrillator was done by Levi Watkins together with the team of Mirowski in Baltimore, USA. Since 1989 implantable cardioverter/defibrillators exhibit multiple functions among which are high energy defibrillation therapy, low energy cardioversion, antitachycardia pacing, permanent and post therapy antibradycardia pacing, diagnostic counters, and device status parameters. This offers a markedly improved technical device to the patients. Evaluation of the patient's diagnostic counters provide a detailed overview about the patient's arrhythmia history and information for optimizing antitachycardia pacing therapy and additional antiarrhythmic drug therapy. The availability of non-thoractomy transvenous lead systems and biphasic shock forms allows the insertion of the device without open chest surgery and even without subcutaneous leads resulting in low mortality rates and an exclusively transvenous system. Single-lead unipolar devices are currently investigated in clinical trials. Future development of atrial sensing lead systems may further reduce inappropriate shock therapy triggered by sinus tachycardia or atrial tachyarrhythmias, e.g. atrial fibrillation, and may be used for dual chamber stimulation. Hemodynamic sensors for determining the severity of the arrhythmia are currently under experimental evaluation. Possible prognostic indications of ICD therapy in patients without a history of malignant arrhythmias are currently studied in several prospective trials. All new directions hold promise to expand and improve the use of ICDs in patients at risk for sudden cardiac death.

Death, Sudden, Cardiac↗

Dobutamine stress echocardiography: initial experience of a Canadian centre.

OBJECTIVE: To investigate the diagnostic accuracy, electrocardiogram and hemodynamic effects and safety of dobutamine stress echocardiography. SUBJECTS: Sixty-one patients with suspected coronary artery disease. All patients underwent coronary arteriography. MAIN RESULTS: The sensitivity of dobutamine stress echocardiography in diagnosis of coronary artery disease in the whole group was 91%. In patients with left anterior descending it was 97%; right 85%; circumflex 76%; three vessel 100%; two vessel 95%; single vessel 77%. Specificity, positive predictive value and accuracy of dobutamine stress echocardiography in diagnosis of coronary disease (whole group) was 57, 94 and 87%, respectively. ST depression of more than 1 mm occurred in 11 patients, ST elevation of more than 1 mm in three patients, T wave inversion in one and T normalization in nine. Significant differences of the effects of beta-blockers were noted on the peak effects of dobutamine as follows: heart rate increase of 46 +/- 22 versus 20 +/- 13 beats/min (P less than 0.0001); systolic pressure increase of 4 +/- 26 versus 22 +/- 19 mmHg (P less than 0.01); diastolic pressure decrease of 18 +/- 16 versus 10 +/- 12 mmHg (P less than 0.03) for patients without or with beta-blockers, respectively. Unifocal ventricular premature beats were noted in 10 patients, atrial premature beats in five and ventricular couplets in one. Angina occurred in 11 patients. Atypical chest pain occurred in seven patients, tingling in 11 and nausea in four. Thirty-six patients were totally asymptomatic. CONCLUSIONS: In this population with high prevalence (85%) of coronary artery disease, dobutamine stress echocardiography had high sensitivity and positive predictive value for coronary disease detection particularly in patients with left anterior descending or three vessel disease. The specificity and accuracy were not as good, but this may reflect the small number of normal patients. Dobutamine was well tolerated and conveniently administered.

Adult↗

Antimicrobial prophylaxis for open heart operations.

Between 1986 and 1988, 450 adults undergoing coronary artery bypass, cardiac valve replacement, or both were enrolled into a prospective, randomized, comparative trial of cephalothin versus cefamandole as perioperative prophylaxis. They were assessed during their hospitalization and at 6 weeks and 6 months after discharge for postoperative infectious complications. Eleven patients had major postoperative infections including 5 with sternal wound infections (three bacteremic), 6 with bacteremia, 1 with prosthetic valve endocarditis, and 3 with severe venous donor graft site infections. Eight major infections occurred in patients receiving cephalothin prophylaxis and three in patients receiving cefamandole, with all five sternal wound infections occurring in the cephalothin group. Postoperative pathogens responsible for the major infections included gram-negative aerobes in 5 patients, Staphylococcus aureus in 4, and Staphylococcus epidermidis in 2. Preoperative colonizing staphylococcal isolates were not predictive of postoperative staphylococcal pathogens. Although there was no statistically significant difference in rate of major postoperative infectious complications using either cephalothin or cefamandole prophylaxis, there was a trend in favor of cefamandole. Gram-negative aerobes are becoming increasingly important pathogens in this setting.

Aged↗