PubMed HealthSearch

Biomedical subjects

L T Fitzgerald

Publications and source records attributed to L T Fitzgerald.

18 recordsLinked to original sources

Adenocarcinoma of the prostate treated with external-beam radiation therapy: 5-year minimum follow-up.

This is a retrospective analysis of 225 patients with localized adenocarcinoma of the prostate who were treated with continuous-course external-beam radiation therapy at the University of Florida between October 1964 and August 1982. All patients were treated 5 or more years prior to the date of analysis, and 30% were eligible for 10-year follow-up. Hormonal treatment was used only in the management of recurrent disease. Ten-year results by stage were as follows: local control--A, 96%; B1, 92%; B2, 51%; C1, 57%; C2, 76%. Relapse-free survival--A, 96%; B1, 58%; B2, 38%; C1, 43%; C2, 61%. Absolute survival--A, 69%; B1, 29%; B2, 47%; C1, 35%; C2, 50%. Freedom from distant metastasis--A, 100%; B1, 55%; B2, 71%; C1, 65%; C2, 77%. Tumor grade was an important prognostic variable in most of the subgroups analyzed. The 5-year rate of distant metastasis was significantly greater in patients with stage C disease when the biopsy was made by transurethral resection of the prostate (TURP) rather than by needle biopsy. In stage B patients, the biopsy method was not prognostically important. For the 48 patients who developed recurrent tumor in the prostate gland, with or without concurrent metastasis, the 5-year absolute survival rate calculated from the date of recurrence was 26%, compared with 10% for the 34 patients who developed distant metastasis alone. Severe complications developed in 5 out of 225 patients (2%) and included three severe rectal injuries, one bladder neck contracture, and one femoral head necrosis. Moderate complications developed in 48 out of 225 patients (21%), with rectosigmoiditis (8%) and hematuria (5%) being the most common problems. For both moderate and severe complications, there was a clear trend toward an increasing complication rate with increasing dose. The method of diagnosis appeared to be a factor in the development of urinary incontinence following irradiation: needle biopsy, 0/106 (0%); TURP, 3/112 (3%); subtotal prostatectomy, 1/7 (needle biopsy versus TURP or prostatectomy, p = 0.076). The frequency of peripheral edema following irradiation was influenced by a history of surgical disruption of the pelvic lymphatics: staging lymphadenectomy, 2/16 (13%), versus no lymphadenectomy, 0/209 (p = 0.005). A comparison with other series is presented.

Adenocarcinoma

The effect of overall treatment time on local control in patients with adenocarcinoma of the prostate treated with radiation therapy.

Studies of patients treated with radiation therapy for squamous cell carcinoma of the head and neck have demonstrated that when all other variables are constant, protraction of the overall treatment time leads to a decreased probability of local control. Few data exist on the effect of overall treatment time on local control following irradiation of tumors that are generally thought to be slowly proliferating, such as adenocarcinoma of the prostate. This analysis was undertaken to determine the time-dose relationships for local control of prostatic adenocarcinoma at the University of Florida. All patients were treated at least 5 years prior to the date of analysis. For patients with Stage A2 disease, a tumor dose of 6500 cGy in 7 to 7.5 weeks to 7000 cGy in 8 weeks resulted in local control in 17/17 patients (100%). For patients with Stage B1 disease, the local control rate was 14/16 (88%) with an overall treatment time of less than or equal to 8 weeks versus 1/3 in patients who received split-course treatment in greater than 8 weeks (p = .097). For patients with Stage B2, C1, and C2 disease who received greater than or equal to 6500 cGy, the 5-year rate of local control was lower when overall treatment time was protracted beyond 8 weeks. Results were as follows: B2 (62 patients), less than or equal to 8 weeks, 88%, versus greater than 8 weeks, 55%, p = .002; C1 (87 patients), less than or equal to 8 weeks, 88%, versus greater than 8 weeks, 73%, p = .052; Cs (33 patients), less than or equal to 8 weeks, 81%, versus greater than 8 weeks, 65%, p = .056. Stratification by tumor grade of patients with Stage B1, B2, C1, and C2 disease who received greater than or equal to 6500 cGy demonstrated significantly lower local control rates for all grade categories when the overall treatment time was protracted beyond 8 weeks. Five-year local control rates (life-table method) for overall treatment time less than or equal to 8 weeks versus greater than 8 weeks were as follows: well differentiated, 93% versus 73% (p = .003); moderately differentiated, 86% versus 69% (p = .017); and poorly differentiated, 75% versus 59% (p = .046). These data suggest that tumor repopulation during excessively protracted treatment may be a clinically significant factor in patients with adenocarcinoma of the prostate.

Adenocarcinoma

A computerized rotating laminar radionuclide camera.

We have constructed a radionuclide camera that embodies a unique detector-collimator concept and provides a radically new approach to imaging. The heart of the instrument is a linear array of semiconductor detectors separated by thin tungsten plates that confine the field of view of each detector to one dimension. This collimator design has a higher collection efficiency than the standard parallel-hole collimator but cannot directly produce a two-dimensional image. When multiple measurements are taken as the array rotates through 180 degrees, a computerized image restoration algorithm can then produce two-dimensional images with resolution determined by the width of the detectors. A small prototype camera has produced images with resolution superior to conventional Anger cameras.

Computers

Electron dose reduction coefficients for seven radionuclides and cylindrical geometry.

In determining internal radiation absorbed dose it is frequently not possible to assume a uniform distribution of radionuclide in an infinite, homogeneous, absorbing material. When the source-target geometry is such that the target is source-free, special considerations must be given to the dose contributions from electrons, since the conventional assumption of 100% absorption of non-penetrating radiations leads to overestimation of the absorbed dose. The absorbed dose from electrons determined at a point within the source-free region depends upon the depth within it. Electron dose reduction coefficients determined at appropriate distances from the source surface are multiplied by the electron doses determined from the general absorbed dose equation. This method of correcting for source-free regions has been applied to cylindrical and planar geometry, for spinal cord and nerve root dosimetry in cisternography. Utilising published scaled point kernels for mono-energetic electrons, electron dose reduction coefficients have been determined as a function of depth from the source surface for cylindrical source-free regions of radii 0.5, 0.05 cm and infinity, and seven gamma-ray-emitting radionuclides: 51Cr, 67Ga, 99Tcm, 111In, 113Inm, 169Yb and 203Pb. These values may be used in other internal radiation absorbed dose situations, and similar techniques applied to other source-target geometries.

Humans

Analysis of errors in three-dimensional reconstruction of radium implants from stereo radiographs.

The present method of steroe shift for three-dimensional (3-D) reconstruction of radium implants has been found to produce displacement errors. Analysis shows that the maximum displacement error decreases as the shift (S) increases with fixed focal spot-film distance (H), while conversely for a fixed shift distance the maximum displacement error with increased focal spot-film distance. The authors suggest that sufficiently accurate 3-D reconstruction may be achieved when H greater than or equal to 100 cm and H/S less than 2.

Computers

Rotating laminar emission camera with Ge-detector: further developments.

A germanium (Ge) camera with laminar collimator-detector geometry, ROLEC, simulating a 195 X 195 mm2 detection area, has been constructed and tested. The detector consists of five separate Ge blocks grooved into distinct electrical channels. Results show that ROLEC measuring times have to be about 3 X greater than Anger camera measuring times to achieve a 5% signal-to-noise ratio with each device. Both spatial and energy resolution of the ROLEC exceed that of the Anger camera but sensitivity variations along the detector strips pose a significant problem in development of a clinically useful device.

Animals

An alternative to conventional shielding for megavoltage therapy rooms.

Dry silica sand as an "in-wall" shielding medium for megavoltage teletherapy rooms is discussed. Shielding considerations, construction techniques, and survey results are presented for a 6-MV facility using sand shielding for both primary and secondary barriers.

Facility Design and Construction