Publications and source records attributed to L Thienpont.

At least 19 recordsLinked to original sources

Preoperative breast MRI in patients with invasive lobular breast cancer.

To investigate the use of MRI in preoperative characterization of invasive lobular breast cancer (ILC) and in detection of multifocal/multicentric disease. We retrospectively reviewed T1-weighted FLASH 3D precontrast and postcontrast MR images together with subtraction images of 26 women with histopathologically proven invasive lobular cancer. Two experienced radiologists described tumor patterns of ILC independently. MR findings of unifocal, multifocal, single quadrant and multiquadrant disease were correlated with results of other imaging techniques and compared with histopathological findings as gold standard. Most ILC presented on MRI as a single spiculated/irregular, inhomogeneous mass (pattern 1, n=12) or as a dominant lesion surrounded by multiple small enhancing foci (pattern 2, n=8). Multiple small enhancing foci with interconnecting enhancing strands (pattern 3) and an architectural distortion (pattern 4) were both described in three cases. There was one case of a focal area of inhomogeneous enhancement (pattern 5) and one normal MR examination (pattern 6). Unifocal and multifocal lesions were identified on MRI in four patients with normal conventional imaging. In nine women, multiple additional lesions or more extensive multiquadrant disease were correctly identified only on MRI. MRI may play an important role in the evaluation of patients with ILC, which is often difficult to diagnose on clinical examination and conventional imaging and more likely occur in multiple sites and in both breasts. However, false-negative MR findings do occur in a small percentage of ILC.

Adult↗

Thyroid fine needle aspiration: the morphological features on ThinPrep slide preparations. Eighty cases with histological control.

This study had several purposes: to define cytomorphological features of thyroid cells that might be modified by alcohol fixation; to optimize May-Grünwald-Giemsa (MGG) staining on ThinPrep(R) (TP; Cytyc Inc., Bexborough, MA, USA) slides and to compare the diagnostic accuracy of slides prepared by a liquid-based method with those obtained by conventional technique. This study included 120 cases of ultrasound-guided fine needle aspiration (FNA) of the thyroid and 55 FNAs performed on surgically resected thyroid specimens. Histological control was available in 80 cases. In the first group of 120 FNAs, a split-sample technique was used for the TP. Three screenings were performed: first, an individual screening of the conventional smears (CS) and of the TP, a second screening to compare cells observed on the TP with the histological control and a third screening to assess the previously defined diagnostic criteria. Twenty-seven TP cases (22%) were considered unsatisfactory for diagnosis compared with 10 in CS (8%). The high rate of unsatisfactory cases with TP is likely to be due to the use of the split-sample technique. The sensitivity was 94% for CS and 81% for TP. The specificity was 67% and 60% for CS and TP, respectively. Two occult papillary carcinomas were missed by both methods. As for the MGG staining, the modified technique used for TP resulted in the same quality as the standard procedure. Conversely, TP did however induce uncommon morphological features. In this study, sensitivity and specificity levels are higher for CS than for TP; the difference may be explained by the fact that the methanol fixative used for TP induces some cytological alterations, especially in oncocytic tumours and lymphocytic thyroïditis.

Adult↗

Breast MR imaging in a patient with unilateral axillary lymphadenopathy and unknown primary malignancy.

Bilateral invasive breast cancers were detected on MR imaging in a patient with left unilateral axillary lymphadenopathy and normal findings at physical examination, mammography, and ultrasound of both breasts. One spiculated and a second ill-defined enhancing lesion in the left breast as well as a superficial circumscribed lesion in the right breast were proven to be invasive malignancies. In patients with isolated axillary lymph nodes and occult primary malignancy, breast MRI can identify or exclude the breast as primary site, which proves the superiority and diagnostic benefit of this imaging method and also its contribution to the therapeutic approach.

Adult↗

Models for combining random and systematic errors. assumptions and consequences for different models.

A series of models for handling and combining systematic and random variations/errors are investigated in order to characterize the different models according to their purpose, their application, and discuss their flaws with regard to their assumptions. The following models are considered 1. linear model, where the random and systematic elements are combined according to a linear concept (TE = absolute value(bias) + z x sigma), where TE is total error, bias is the systematic error component, sigma is the random error component (standard deviation or coefficient of variation) and z is the probability factor; 2. squared model with two sub-models of which one is the classical statistical variance model and the other is the GUM (Guide to Uncertainty in Measurements) model for estimating uncertainty of a measurement; 3. combined model developed for the estimation of analytical quality specifications according to the clinical consequences (clinical outcome) of errors. The consequences of these models are investigated by calculation of the functions of transformation of bias into imprecision according to the assumptions and model calculations. As expected, the functions turn out to be rather different with considerable consequences for these types of transformations. It is concluded that there are at least three models for combining systematic and random variation/errors, each created for its own specific purpose, with its own assumptions and resulting in considerably different results. These models should be used according to their purposes.

Algorithms↗

Assessment of the state-of-the-art trueness and precision of serum total-calcium and glucose measurements in Finnish laboratories--the QSL-Finland study.

The purpose of the QSL-Finland study was to assess the state-of-the-art trueness and precision of serum total-calcium and glucose measurements in Finnish clinical laboratories. For this purpose, 21 hospitals and clinical institutes were selected. They measured six single donation sera, the total-calcium (t-calcium) and glucose content of which had been determined by ion chromatography and isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) reference methods. The results were interpreted in light of specifications for imprecision, bias and total error of routine methods that have been proposed in the past. The data revealed that the performance of t-calcium and glucose methods is generally acceptable in Finnish clinical laboratories. This study did not lead to a separation of laboratories according to accreditation. In consequence, it seems that accreditation, in its present form, cannot substitute dedicated quality assurance practices.

Blood Glucose↗

Graphical interpretation of analytical data from comparison of a field method with reference method by use of difference plots.

Various viewpoints have been offered regarding the appropriate use of scatter plots or difference plots (bias plots or residual plots) in comparing analytical methods. In many of these discussions it seems the basic concepts of identity (within inherent imprecision) and acceptability based on analytical goals (analytical quality specifications) have been forgotten. With the increasing number of Reference Methods in laboratory medicine, these basic concepts are becoming more important in validation of field methods. Here we describe a simple and effective graphical test of these hypotheses (identity and acceptability) by use of difference plots. These plots display the underlying hypothesis before the measured differences are plotted and allow interpretation of the results according to specific criteria. We further describe simple but effective interpretations of the data, when the hypothesis is not fulfilled, by using two data sets drawn from comparisons of field methods for S-creatinine with a Reference Method for this analyte. The difference plot is a graphical tool with related simple statistics for comparison of a field method with a Reference Method, focusing on (a) identity within the inherent analytical imprecision or (b) acceptability within analytical quality specifications. Calculation of the standard deviation of the differences is an indispensable tool for evaluation of aberrant-sample bias (matrix effects).

Chemistry, Clinical↗

External quality assessment: currently used criteria for evaluating performance in European countries, and criteria for future harmonization.

A questionnaire was circulated to European countries seeking information on the criteria used for acceptable performance in external quality assessment schemes. Responses were obtained from 21 countries. Fixed limits are used in 13 countries but the basis for these varies widely and includes clinical decision making, biological variation, views of experts, the state-of-the-art, and combinations of approaches. Variable limits based upon statistical analysis of the performance attained are used in 8 countries. The many advantages of harmonization in Europe have prompted the development of criteria based upon within- and between-subject biological variation for use in schemes which circulate single specimen challenges. Currently used criteria, which show much diversity, are compared with these proposals, and the empirical nature of the majority of the former is demonstrated.

Chemistry, Clinical↗

Characterization and classification of external quality assessment schemes (EQA) according to objectives such as evaluation of method and participant bias and standard deviation. External Quality Assessment (EQA) Working Group A on Analytical Goals in Laboratory Medicine.

Within the scope of this paper, the Working Group has attempted to place external quality assessment (EQA) within the whole context of quality management in laboratory medicine. First, the objectives of EQA schemes are defined and current EQA schemes evaluated. In most schemes, the objectives are not defined a priori and do not allow the definition of the origin of unacceptable individual results from participants. There is an ongoing trend for making traditional EQA schemes more interesting for the participants. Analysis of the factors involved in analytical quality allow the definition of the essential analytical tasks of educational EQA schemes. Beside these quality control tasks, educational EQA also includes quality assurance elements. EQA today has not only an important role to play in the assessment of each participant's performance but also in the assessment of the method. Efficiency of the schemes and educational impact can be improved by appropriate scheme designs according to objectives. After this theoretical approach, some practical examples of problem related EQA designs are given.

Clinical Laboratory Techniques↗

Proposed guidelines for the internal quality control of analytical results in the medical laboratory.

The factors involved in analytical quality relate to definition of quality, creation of quality, and control of quality, and errors arise from external and internal sources as well as from permanent and variable factors. Further, the two main types of error are classified as systematic and random errors. Internal quality control (IQC) systems can only operate on the variable factors which are related to batch-to-batch variations (external factors) and to the performance in the laboratory (internal factors). In creating an adequate internal control system, several problems are faced: (i) quality of control materials, (ii) types and frequency of possible errors, (iii) number and types of control materials, (iv) number of replicates of the control, (v) probability of error detection, (vi) probability of false rejection, (vii) consequences of reject signals, (viii) trouble-shooting systems, and (ix) prevention of errors among many other conditions. Gaussian distributions of control results are assumed and the statistical control rules are evaluated in relation to probability of false rejections, Pfr, and probability of error detection, Ped, for the different rules. Combinations of low Pfr and high Ped are obtained by combining results from e.g. four measurements of the same control sample by use of mean and range rules. Further, it is not possible to establish a common control system which can be used for all quantities and analytical procedures; on the contrary, each procedure should have its particular efficient IQC system. These aspects are discussed and a number of guidelines for statistical control rules and problem related internal quality control are presented.

Guidelines as Topic↗

Analytical quality specifications for reference methods and operating specifications for networks of reference laboratories. discussion paper from the members of the external quality assessment (EQA) Working Group B1) on target values in EQAS.

The aim of the Working Group was to describe guidelines for the establishment of networks of reference laboratories. The need for such networks to achieve an accuracy-based uniform measurement system with traceability of results of analytical systems/test-kits to the true value is outlined. Criteria for analytical quality specifications, which are related to the ultimate purpose of the reference method and thereby to the objectives of the networks, are emphasized. The group recommends the use of two models: one based on specifications for routine methods, which are dictated by the biological variations of the respective analytes, the second respecting the analytical state-of-the-art of reference methodology. Further, the group presents operating specifications for networks that guarantee the continuous performance of reference method measurements whilst maintaining a uniform and stable level of quality.

Chemistry, Clinical↗

Development, validation, and certification by isotope dilution gas chromatography-mass spectrometry of lyophilized human serum reference materials for cortisol (CRM 192 and 193) and progesterone (CRM 347 and 348).

The Community Bureau of Reference of the European Communities has produced four batches of lyophilized serum Certified Reference Materials, two for cortisol (CRM 192 and 193) and two for progesterone (CRM 347 and 348). For cortisol, one of the pools consisted of serum from healthy blood donors, whereas the second batch was supplemented with pure cortisol. The progesterone Reference Materials contained only endogenous hormone concentrations. Assessment of vial-to-vial variability in the cortisol and progesterone concentrations showed no between-sample inhomogeneity, and the materials were stable. The quality of the materials was therefore considered sufficient for certification of the values for the cortisol and progesterone concentrations by a collaborative study involving several laboratories from the European Communities, using isotope dilution gas chromatography-mass spectrometry. Inaccuracy in reconstitution of the lyophilized materials was less than 0.3%; imprecision of sampling was less than 0.2%. For determinations of cortisol and progesterone concentrations, the mean within-laboratory coefficients of variation (CVs) were 1.76% (CRM 192), 1.19% (CRM 193), 1.64% (CRM 347), and 1.75% (CRM 348). The between-laboratory CVs were greater: CRM 192, 1.79%; CRM 193, 1.48%; CRM 347, 2.08%; and CRM 348, 2.16%. The concentrations in the reconstituted Reference Materials were certified to be 273 nmol/L in CRM 192 and 763 nmol/L in CRM 193 for cortisol and 10.13 nmol/L in CRM 347 and 40.3 nmol/L in CRM 348 for progesterone. Uncertainties at the 0.95 confidence level--6 (CRM 192), 14 (CRM 193), 0.21 (CRM 347), and 1.0 nmol/L (CRM 348)--were considered compatible with the intended use of the materials.

Blood Chemical Analysis↗

Venous air embolism following insufflation of the urethra.

Venous air embolism following urethral inflation only scarcely documented: an extensive search of the literature yielded four papers relating to this subject. We report a new case of venous air embolism due to this uncommon etiology. Careful study revealed some common pathogenetic features with previously reported cases. Some important precautions can diminish the likelihood of gas embolism and reduce its fatal outcome in situations, similar to the kind mentioned.

Aged↗