A template-free approach for determining the latency of single events of auditory evoked M100.

The phase of the complex output of a narrow band Gaussian filter is taken to define the latency of the auditory evoked response M100 recorded by magnetoencephalography. It is demonstrated that this definition is consistent with the conventional peak latency. Moreover, it provides a tool for reducing the number of averages needed for a reliable estimation of the latency. Single-event latencies obtained by this procedure can be used to improve the signal quality of the conventional average by latency adjusted averaging.

Evoked Potentials, Auditory↗

Spatial distribution of cardiac magnetic vector fields acquired from 3120 SQUID positions.

An extended measurement of the magnetic vector field of the human heart is presented. It is acquired by sequential recordings, shifting a 16 SQUID vector magnetometer across 195 positions over a healthy subject's thorax. The magnetocardiographic (MCG) signals were synchronized using a simultaneously measured ECG channel. The registration of the field extends over a volume of 1000 mm x 600 mm x 420 mm sampled at 3120 SQUID positions. We present diagrams of the vector amplitude of selected points in 6 planes at increasing distances from the frontal thorax. Each plane contains 76 vector points. Additionally, we measured the vector field at 126 points lateral to the chest. At the edge points of the measurement volume, the absolute value of the magnetic vector signal amplitude exceeds 0.3 pT in all measurement points. The dataset provides an excellent base to study dedicated MCG detection or rejection methods. Examples where rejection of the heart signal is necessary are magnetoencephalography, magnetoneurography and fetal MCG. The knowledge of the spatio-temporal distribution of the magnetic vector field of the heart supports the development and comparison of multi-SQUID systems and will be used to create new MCG interpretation and representation algorithms.

Body Surface Potential Mapping↗

Discrimination of multiple sources using a SQUID vector magnetometer.

For many biomagnetic applications the discrimination between simultaneously active sources is required. To evaluate the performance of a given SQUID system in this respect, the angle between the signal vectors of different sources is used. If the angle reaches large values, discrimination between the multiple sources is possible. We tested this approach with the first module of a new vector magnetometer system consisting of 19 identical modules. Two examples of measurements illustrate the differentiation of multiple sources, i.e. the fetal and the mother's heart signal, and alpha rhythm and heart signal in MEG recordings. This first module of a vector magnetometer system containing 16 SQUIDs is operated at PTB in the new Berlin Magnetically Shielded Room (BMSR 2) The spatial configuration of the 16 integrated SQUID magnetometers of the module is such that all three vector components of the magnetic field can be calculated in three measurement planes at 1.5 cm, 5 cm, and 10.5 cm above the Dewar bottom, respectively. The SQUID magnetometer channels have a typical white noise level of less than 2.3 fT/square root of Hz1/2 at 1 kHz.

Electromagnetic Fields↗

Systematic latency variation of the auditory evoked M100: from average to single-trial data.

Standard analyses of neurophysiologically evoked response data rely on signal averaging across many epochs associated with specific events. The amplitudes and latencies of these averaged events are subsequently interpreted in the context of the given perceptual, motor, or cognitive tasks. Can such critical timing properties of event-related responses be recovered from single-trial data? Here, we make use of the M100 latency paradigm used in previous magnetoencephalography (MEG) research to evaluate a novel single-trial analysis approach. Specifically, the latency of the auditory evoked M100 varies systematically with stimulus frequency over a well-defined time range (lower frequencies, e.g., 125 Hz, yield up to 25 ms longer latencies than higher frequencies, e.g., 1000 Hz). Here, we show that the complex filtering approach to single-trial analysis recovers this key characteristic of the M100 response, as well as some other important response properties relating to lateralization. The results illustrate (i) the utility of the complex filtering method and (ii) the potential of the M100 latency to be used for stimulus encoding, since the relevant variation can be observed in single trials.

Acoustic Stimulation↗

Oesophageal transport of solid dosage forms depends on body position, swallowing volume and pharyngeal propulsion velocity.

Knowledge about transit of solid dosage forms (SDF) in the gastrointestinal tract is incomplete. Detection of magnetically marked capsules (MMC) via superconducting quantum interference device (SQUID) allows monitoring of oesophageal transport of SDF with high tempospatial resolution. The aim of the study was to investigate the influence of body position, volume at swallowing, and oesophageal motility on orogastric transport of SDF. In 360 measurements we determined tempospatial characteristics of orogastric transit of SDFs by a SQUID device in six volunteers. They swallowed MMCs with various amounts of water in upright and supine position with and without simultaneous oesophageal manometry. Orogastric transit time, oesophageal transport velocity and rate of oesophageal retention of SDF depend on swallowing volume and body position at all experimental conditions. At 50 mL water bolus and in upright position, the retention rate depends on the pharyngeal propulsion velocity, and the transport velocity of MMCs in the oesophageal body are faster than the propulsive oesophageal contractions. Body position, swallowing volume and pharyngeal propulsion velocity markedly influence the oesophageal transport of SDF. They should be taken in upright body position with at least 50 mL of water to minimize entrapment in the oesophagus.

Adult↗

Imaging characteristics of different multichannel magnetocardiographic systems.

In this study a comparison of multichannel magnetocardiographic systems is performed with respect to the "detectable" information content. We investigate the lead-field matrices, the slope of the singular values and the source spaces of three different devices: the VectorView (Neuromag: magnetometer-gradiometer mixed device) of the BioMag Laboratory, Helsinki University Central Hospital (HUCH), the arrangement of electronically coupled magnetometers of the Physikalisch-Technische Bundesanstalt Berlin (PTB) and a virtual sensor geometry which was optimized for an improved slope of the singular values at the Institute of Biomedical Engineering, Karlsruhe.

Adult↗

Investigation of gastrointestinal transport by magnetic marker localization.

The method of magnetic marker monitoring MMM with a biomagnetic measurement system allows the tracking of the transport of solid drug forms with high spatiotemporal resolution. This technique enables to display the path and the disintegration of the magnetic marked pharmaceutical dosage form via the decrease of its magnetic moment. The method was used to assess exogenous factor on the esophageal transport of orally administered solid drug forms in five healthy volunteers. In a drug delivery study we have applied the MMM to monitor the path of a tablet during the gastrointestinal passage and to visualize the disintegration in the small intestine by the magnetic moment of the tablet. The signal to noise ratio of the measurement data was improved by ICA filtering.

Acetaminophen↗

Time-delayed decorrelation for the identification of cardiac artifact components in MEG data.

The time-delayed decorrelation (TDD) Independent Component Analysis (ICA) applied to continuous multichannel magnetoencephalographic (MEG) recordings is a straightforward calculation in the time domain: Its main ingredient is a calculation of the correlation between signals having different time shifts with respect to each other. The equivalent mathematical representation in the frequency domain and a simple simulation show that TDD exploits different complex frequency spectra of the sources. Applying ICA to 80-channel whole head MEG data obtained under visual stimulation we can assign five of the 80 source components to the cardiac artifact. Their complex spectra exhibit a randomly distributed phase showing that TDD is capable of isolating quasi-periodic signals even for the case of an unspecified phase.

Algorithms↗

MEG-analysis using the Hilbert transform.

Event-related fields (ERFs) measured by magnetoencephalography (MEG) upon visual stimulation are analysed by Hilbert transformation. The Hilbert transform of real-valued measured ERF is an analytic complex signal, represented by phase and amplitude. The temporal behaviour of the derivative of the phase, i.e. the instantaneous frequency, allows to distinguish time intervals containing meaningful signal from noise. On the basis of both phase and amplitude, energies and latencies of single event ERFs can be determined.

Evoked Potentials, Visual↗

Non-invasive single-trial monitoring of human movement-related brain activation based on DC-magnetoencephalography.

Neuroimaging techniques, such as fMRI, PET and near-infrared spectroscopy, monitor task-related neuronal activations in the brain indirectly through the associated neurovascular/metabolic responses. To assess the primary neuronal activations directly, magnetoencephalography was combined here with a mechanical modulation of the head-to-sensor position and signal separation via independent component analysis. In all of five subjects this approach allowed to monitor the time evolution of DC fields (<0.1 Hz) over the left hemisphere related to complex finger movements of the right hand alternating with rest periods (30 s each). Throughout the recording period of 30 min, stable task-related DC fields were recordable in a single-trial mode, i.e. without any averaging. DC-MEG opens up the possibility of analysing non-invasively cortical DC-activity also in stroke, migraine or epilepsy patients.

Adult↗

Magnetic marker monitoring of disintegrating capsules.

Magnetic marker monitoring was studied for its applicability to investigate the in vivo fate and behavior of disintegrating magnetically marked dosage forms. As a model, hard gelatin capsules were filled with an effervescent mixture of lactose, ascorbic acid and sodium hydrogen carbonate containing 1.3 mg black iron oxide as a magnetic label. The accuracy of the localization procedure whilst calculating all parameters of the dipole in one fitting procedure was checked in phantom experiments where the capsules were moved in well-defined paths with respect to the measurement device. The calculated position coordinates of the capsules deviated between less than 2 mm up to 8 mm from the expected position values depending on the distance between the sensor area and the capsule's path. Further experiments on the in vitro disintegration of the capsules showed that the value of the magnetic moment of the capsules can serve as a measure for their disintegration behavior. In vivo monitoring of the capsules was performed in eight experiments where a healthy volunteer swallowed each time one of the capsules. It was found that the in vivo disintegration behavior of the capsules corresponds well to their disintegration observed in water of about 37 degrees C.

Adult↗

Magnetoneurography of evoked compound action currents in human cervical nerve roots.

OBJECTIVE: A measurement protocol for magnetoneurography (MNG) is established which allows the non-invasive localization and tracing of evoked compound action currents propagating along cervical nerve roots in man. METHODS: Inside a magnetically shielded room either both median or both ulnar nerves of healthy subjects were conventionally electrostimulated in alternation. Evoked magnetic responses were recorded using a multichannel SQUID-detector with a planar measuring area centered over the neck. Simultaneously, electric surface potentials were recorded using cervical bipolar electrode montages. RESULTS: Upon median (ulnar) nerve stimulation somatosensory evoked magnetic fields up to 20 fT (10 fT) amplitude were detected propagating over the cervical transforaminal root entry zone, with corresponding electrical surface potentials of 1.5 microV (0.5 microV). Furthermore, the signal-to-noise ratio of the spatiotemporal magnetic field mappings in median nerve stimulation experiments allowed dipolar source reconstructions and tracing of the propagation of the compound action currents along nerve root fibers. CONCLUSION: Magnetoneurography allows tracing of the propagation of evoked compound action currents along cervical roots in healthy subjects with millisecond temporal and high spatial resolution. Thus, MNG offers a sensitivity appropriate to serve as a clinical diagnostic tool for localizing focal neuropathies of cervical nerve roots.

Electric Conductivity↗

Tracing of proximal lumbosacral nerve conduction--a comparison of simultaneous magneto- and electroneurography.

OBJECTIVE: The reconstruction of nerve impulse conduction along proximal lumbosacral plexus and nerve roots is compared using simultaneous magneto- and electroneurography. METHODS: In 3 healthy subjects the left tibial nerve was electrostimulated at the ankle. Evoked magnetic fields and electric surface potentials were measured simultaneously over the lumbosacral spine using a multichannel SQUID-detector with a planar measuring area and 25 surface electrodes covering a comparable area centered around L4. Based on either magnetic field or electric potential maps the depolarization front of the evoked compound action currents (CAC) was spatio-temporally reconstructed using a simple equivalent current dipole model in a half-space volume conductor. RESULTS: The mean signal-to-noise ratio in the magnetic (electric) recordings was around 4 (8). Yet, the localization quality for the propagating CAC was lower for electric than magnetic recordings. The local nerve conduction velocity was around 47 m/s (calculated from magnetic data), but fluctuated unphysiologically for electric data. CONCLUSION: In comparison to electroneurography, an anatomically reasonable localization of evoked compound action currents propagating in lumbosacral roots can be obtained by magnetoneurography.

Adult↗

Magnetocardiographic intra-QRS fragmentation analysis in the identification of patients with sustained ventricular tachycardia after myocardial infarction.

The aim of this study was to investigate if magnetocardiographic (MCG) analysis of cardiac micropotentials within the QRS complex can identity patients prone to ventricular arrhythmias, and to compare it to MCG time-domain, late-field analysis. The study population consisted of 136 patients with remote MI, 53 with and 83 without a history of VT. After averaging and high pass filtering of multichannel MCG signals, time-domain parameters describing the end-QRS activity and fragmentation index M and score S describing the whole QRS complex were computed. Fragmentation and time-domain parameters differed between the VT and control groups: fragmentation index M was 12 +/- 3 versus 9 +/- 2 (P <0.001), fragmentation score S was 83 +/- 42 versus 56 +/- 21 (P < 0.001), and filtered QRS duration was 144 +/- 32 versus 114 +/- 19 ms (P < 0.001) in VT and control groups, respectively. A combination of fragmentation parameters yielded 87% sensitivity and 61% specificity in VT identification. Corresponding figures for a time-domain parameter combination were 81% and 72%. Sensitivity of time-domain analysis was 88% and specificity was 75% in a subgroup with anterior MI. In multivariate analysis, fragmentation and time-domain analyses discriminated VT patients from controls independently of the extent of coronary artery disease or left ventricular dysfunction. MCG in postinfarction patients reveals pathology associated with propensity to ventricular arrhythmias inside and not only at the end of the QRS complex. MCG seems most accurate in the anterior infarct location.

Aged↗

Variability of the QRS signal in high-resolution electrocardiograms and magnetocardiograms.

The variability of electric and magnetic signals from the heart during the depolarization phase is investigated. A signal processing method is developed, which provides estimates for the beat-to-beat variability of the QRS-complex. The method is based on the decomposition of the depolarization signal into bandpass signals by means of the Morlet wavelet transform. The beat variability of the depolarization signal is estimated by normalized variances of the envelope and instantaneous frequency of bandpass signals. Time intervals of the bandpass filtered depolarization signals having a high signal-to-noise ratio are selected applying an analysis based on phase statistics. The method was tested by computer simulation and experimental data taken from electrocardiographic and magnetocardiographic measurements of healthy persons and patients prone to malignant ventricular tachycardia (VT) or ventricular fibrillation (VF). Results suggest that the calculated variance parameters permit the characterization of beat variable depolarization signals and distinguish VT/VF patients from healthy persons.

Algorithms↗

Non-invasive magnetoneurography for 3D-monitoring of human compound action current propagation in deep brachial plexus.

Compound action current (CAC) propagation along nerve fibers running deep in the human brachial plexus was 3D-visualized based on non-invasive 49-channel superconducting quantum interference device (SQUID) magnetoneurography. Spatio-temporal mappings over the upper thoracal quadrant of magnetic fields (<100 fT) evoked upon alternating median and ulnar nerve stimulation in seven healthy volunteers showed consistently smoothly propagating dipolar patterns for both the CAC depolarization and repolarization phases. Multipolar current source reconstructions (i) distinguished spatially CAC propagation pathways along either median or ulnar plexus fibers, allowed (ii) to calculate local conduction velocities ( approximately 56 m/s) and (iii) even to estimate the CAC extension along the nerve fibers (depolarization phase: approximately 11 cm). Thus, for deep proximal nerve segments magnetoneurography can provide a detailed tracing of neural activity which is a prerequisite to localize non-invasively focal nerve malfunctions.

Action Potentials↗

Hyperventilation-induced human cerebral magnetic fields non-invasively monitored by multichannel 'direct current' magnetoencephalography.

Self-paced hyperventilation (HV) induces slow cerebral magnetic field changes which were monitored and mapped continuously over 15 min using 49-channel DC-coupled ('direct current') magnetoencephalography (DC-MEG) based on a modulation technique. In nine/nine healthy subjects HV caused an increase (range: 1.1-6.2 pT) of the mean global DC-MEG field strength which slowly decayed after HV termination (mean time constant: 2 min). The complex HV-related field patterns were distinctly different from mainly dipolar somatosensory evoked field maps (N20m) in four/four subjects. Thus, current sources in the primary somatosensory cortex need not regularly dominate DC-field changes as had been previously considered. Rather, DC-MEG enabled the monitoring of a widely distributed HV-induced enhanced cortical excitability which may serve as model to study epileptic or post-anoxic cerebral hyperexcitability.

Adult↗

Identification of post-myocardial infarction patients with ventricular tachycardia by time-domain intra-QRS analysis of signal-averaged electrocardiogram and magnetocardiogram.

A new time-domain analysis method, which quantifies ECG/MCG intra-QRS fragmentation, is applied to parts of the QRS complex to identify post-myocardial infarction patients with ventricular tachycardia. Three leads of signal-averaged electrocardiograms and nine leads of magnetocardiograms were band-pass filtered (74 Hz to 180 Hz). The filtered signals showed fragmentation in the QRS region, which was quantified by the number of peaks M and a score S, that is the product of M and the sum of the peak amplitudes. Both parameters were determined for the first 80 ms of the QRS complex and the total QRS complex in each channel. For classification, the mean-values of the parameters M and S of the three electrical leads and the nine magnetic leads were calculated. Late potential and late field analyses were performed for the same signals. 31 myocardial infarction patients were included, 20 of them with a history of documented ventricular tachycardia (VT). Identification of VT patients using the SAECG led to better results (sensitivity 95%, specificity 91%) considering the entire QRS complex than with the standard late potential analysis suggested by Simson (sensitivity 90%, specificity 73%). For the SAMCG and the entire QRS complex results using the parameters S and M are also better (sensitivity 95%, specificity 100%) than for the late field analysis (sensitivity 90% and specificity 100%). For the first 80 ms, the performance of the parameters M and S is only slightly decreased.

Adult↗