PubMed Health⌕ Search

Biomedical subjects

L V Galbraith

Publications and source records attributed to L V Galbraith.

4 recordsLinked to original sources

Elevated serum chromium in patients on total parenteral nutrition and the ionic species of contaminant chromium.

Chromium (Cr), an essential micronutrient required for glucose metabolism, was found in high concentrations in up to 94% of the patients on short-term total parenteral nutrition. Approximately 50% had serum levels > 10-fold of normal (upper reference value of 3.8 nmol/L), about 18% were > 20-fold, and about 2% were 40-fold higher. The major Cr contaminant was detected in the amino acid constituents, and was found to have the trivalent ionic form. Although trivalent Cr is reported to be less genotoxic, further study is required to determine the effects on cells exposed to high concentrations of this element during parenteral nutrition over an extended period of time.

Adolescent↗

Time-related changes in the diagnostic utility of total lactate dehydrogenase, lactate dehydrogenase isoenzyme-1, and two lactate dehydrogenase isoenzyme-1 ratios in serum after myocardial infarction.

Using receiver-operating characteristic (ROC) curve and likelihood ratio analysis, we examined the diagnostic utility of total lactate dehydrogenase (LD; EC 1.1.1.27) activity (I). LD isoenzyme-1 activity (II), and the LD-1 percentage of total LD activity (III), LD-1 LD-2 (IV), and LD-1/LD-4 (V) in 347 persons admitted to the Cardiac Care Unit (of whom 173 were subsequently proven to have had myocardial infarction). Blood was sampled from these subjects at about 6-h intervals for up to 96 h from the onset of chest pain. Defining an "effective" test as one having an area under the ROC curve of greater than or equal to 0.9, we determined the ranked utility (greatest to least) of these tests as V = IV greater than III greater than II greater than I. Tests III, IV, and V had by this criterion, diagnostic effectiveness equivalent to measurements of creatine kinase-2 in serum but in samples obtained at later time intervals. The decision thresholds for both high (constant) test sensitivity and specificity varied with time, to differing extents, over the entire 96-h period, a finding with important diagnostic implications. We document positive and negative likelihood ratio values for each of these tests throughout the entire period of study.

Adult↗

A computer program to determine diagnostic decision thresholds and likelihood ratios illustrated with aspartate aminotransferase activities after a myocardial infarction.

We describe an enhancement of our earlier computer program which allows calculation of decision thresholds, sensitivity and specificity, and likelihood ratios of negative and positive test results for any chosen value of sensitivity or specificity. The program will also plot continuous receiver operating characteristic and decision level curves which permit examination of the contours created by using all the available data. We illustrate the value of these routines by showing that the sensitivity and specificity of serum aspartate aminotransferase changes during the course of a myocardial infarction.

Aspartate Aminotransferases↗

Re-evaluation of the diagnostic utility of serum total creatine kinase and creatine kinase-2 in myocardial infarction.

The diagnostic utility of total creatine kinase activity (I), creatine kinase-2 isoenzyme activity (II), and II as a percentage of I, was examined by receiver-operating characteristic curve and likelihood ratio (LR) analyses in 310 persons admitted to the Coronary Care Unit (151 proven cases of myocardial infarction and 159 non-myocardial infarction controls), from whom blood was sampled at 6-h intervals for 48 h after the onset of chest pain. I was ineffective either as a "rule-in" or as a "rule-out" test within the first 6 h of the onset of chest pain; thereafter, it was an effective test. II was the most effective test during the entire 48-h period. III was more effective than I in the first 24-h period, but was less effective than I during the next 24-h period. The decision threshold for high test sensitivities varies with time over the entire 48-h period, but remains constant for high test specificities. It is essential to tabulate the LR(+) and LR(-) values for both test sensitivity and specificity at constant values to determine the utility of each test at each time interval for respectively ruling out or ruling in a diagnosis of myocardial infarction.

Creatine Kinase↗