Effect of vessel size on the flow efficiency of the total cavopulmonary connection: in vitro studies.

The total cavopulmonary connection (TCPC) creates a passive system of blood flow into the pulmonary circulation. We hypothesize that the efficiency differences found in models with superior vena cava-inferior vena cava (SVC-IVC) offsets is dependent on vessel size, with flow efficiency improving with larger size vessels. Two sets of in vitro TCPC models (TCPC-3 and TCPC-15) were constructed corresponding to average vessel diameters of 3- and 15-year-old patients. The model with full SVC-IVC offset was the most efficient in TCPC-3 models. There was no significant difference between geometric arrangements in TCPC-15 models; however, the average efficiencies were significantly higher. Among the models representing vessel sizes of the younger age group, the model with the full-diameter SVC-IVC offset was the most efficient. The models representing vessel sizes of the older age group showed marked improvement in efficiencies throughout without obvious differences between various geometric arrangements. This suggests that geometric considerations in TCPC surgical techniques may be of lower than expected significance over the life span of a patient. More important, after balancing the effects of improved flow efficiency with larger vessels against the effects of chronic volume overload, the trend of performing the Fontan surgery on increasingly younger patients may need to be reconsidered after further studies.

Adolescent↗

Development of a noninvasive ultrasound color M-mode means of estimating pulmonary vascular resistance in pediatric pulmonary hypertension: mathematical analysis, in vitro validation, and preliminary clinical studies.

BACKGROUND: Accurate determination of pulmonary vascular resistance (PVR) is an important component in the evaluation and treatment of pediatric patients with pulmonary hypertension. We developed a novel technique, based on the concept of flow propagation, to estimate PVR noninvasively. The hypothesis is that changes in PVR cause changes in the velocity propagation (Vel(prop)) within the main pulmonary artery and that Vel(prop) can be quantified using color M-mode imaging. METHODS AND RESULTS: We tested the hypothesis using mathematical modeling, in vitro experiments, and preliminary clinical studies. The mathematical model showed that pressure and velocity tracings are closely correlated in time and that 6 to 18 ms time resolution was needed to resolve propagation times within typical main pulmonary artery lengths (2 to 5 cm). The in vitro experiments demonstrated that it was feasible to use color M-mode to measure Vel(prop) and that Vel(prop) correlated well with downstream resistance [y=(-1.01x)+22.77; R=0.96]. The method was then evaluated on patients undergoing acute pulmonary reactivity testing (n=22 measurements). Good correlation between Vel(prop) and PVR was found [y=(-1.71x)+26.0; R=0.90; SEE=2.41]. CONCLUSION: This newly developed method promises to be useful in the noninvasive evaluation of adults and children with pulmonary hypertension.

Adolescent↗

Artificial neural network-based method of screening heart murmurs in children.

BACKGROUND: Early recognition of heart disease is an important goal in pediatrics. Efforts in developing an inexpensive screening device that can assist in the differentiation between innocent and pathological heart murmurs have met with limited success. Artificial neural networks (ANNs) are valuable tools used in complex pattern recognition and classification tasks. The aim of the present study was to train an ANN to distinguish between innocent and pathological murmurs effectively. METHODS AND RESULTS: Using an electronic stethoscope, heart sounds were recorded from 69 patients (37 pathological and 32 innocent murmurs). Sound samples were processed using digital signal analysis and fed into a custom ANN. With optimal settings, sensitivities and specificities of 100% were obtained on the data collected with the ANN classification system developed. For future unknowns, our results suggest the generalization would improve with better representation of all classes in the training data. CONCLUSION: We demonstrated that ANNs show significant potential in their use as an accurate diagnostic tool for the classification of heart sound data into innocent and pathological classes. This technology offers great promise for the development of a device for high-volume screening of children for heart disease.

Adolescent↗

Echocardiographic outcome of infants treated as newborns with inhaled nitric oxide for severe hypoxemic respiratory failure.

OBJECTIVE: To determine the cardiovascular outcome of a group of term newborns treated with inhaled nitric oxide (iNO) for severe hypoxemic respiratory failure with associated persistent pulmonary hypertension. STUDY DESIGN: We performed echocardiographic evaluations in 40 survivors treated for severe neonatal hypoxemic respiratory failure. Each of the 40 had at least 2 follow-up echocardiograms at 3 or 6 and 24 months. These studies were compared with echocardiograms done in infants in a normal, age-matched control group. RESULTS: Three of 31 infants met echocardiographic criteria for pulmonary hypertension at the 3-month examination. Two of the 3 had associated structural heart disease (1 with an atrial septal defect and 1 with a ventricular septal defect). At 24 months only 1 patient had pulmonary hypertension. This infant had an atrial septal defect that was surgically closed shortly after the 24-month echocardiogram because of the pulmonary hypertension. Group comparisons of 3- and 24-month echocardiographic variables showed no differences between the study and control groups. In the 31 infants in whom serial studies were completed, expected age-related changes were demonstrated between the 3- and 24-month examinations. CONCLUSIONS: The incidence of residual pulmonary hypertension in infants treated as newborns for severe hypoxemic respiratory failure is low. The group at highest risk is those with structural heart disease.

Administration, Inhalation↗

A general method for estimating deformation and forces imposed in vivo on bioprosthetic heart valves with flexible annuli: in vitro and animal validation studies.

BACKGROUND AND AIM OF THE STUDY: The use of flexible structures within cardiovascular prostheses such as valves, stents and vascular grafts has been proposed as a means of more closely modeling native mechanics, and thereby reducing the biomechanical problems associated with rigid materials. However, the design of such materials has been hampered by the paucity of quantitative information on the in-vivo behavior of such structures. The aim of this study was to explore the use of 3D ultrasound imaging coupled with finite element analysis (FEA) as a tool to estimate deformation and forces imposed in vivo on a novel bioprosthetic valve design. METHODS: The method was first tested using in-vitro static loading conditions, where good agreement between displacements seen on video and those obtained from application of the identical force within the finite element program was seen. The method was then tested in a porcine model with valves implanted in the mitral position. Images of the deforming annular ring were obtained over the cardiac cycle using 3D intravascular ultrasound; these images were fed into the FEA program for calculation of reaction forces. RESULTS: Results in vitro showed that a force of 2.7-8.0 Newtons (N) was required to produce a deformation of between 1.0 and 3.0 mm in the radial direction. A time history of deformation and force around the ring of the valve stent could be obtained for the in-vivo conditions. These results revealed a maximum deformation of 0.5-1.7 mm along the short axis (anteroposterior) of the mitral valve. Coupled to this, a peak reaction force of 4.4-13.9 N was found at the points corresponding to maximal deflection. Both deformation and reaction force reached maximum during atrial contraction. CONCLUSION: This method provides an accurate means of estimating deformation and corresponding forces imposed in vivo on intracardiac prostheses. The results provide information on the dynamic behavior of the mitral valve annulus. Such information should be useful in the design of flexible cardiovascular prostheses.

Animals↗

A method for determining the reference effective flow areas for mechanical heart valve prostheses: in vitro validation studies.

BACKGROUND: The anatomic opening area (AOA) is usually reported as the primary index of mechanical heart valve function. Because flow contracts immediately distal to an orifice as a result of the vena contracta effect, AOA may not be a good measure of true effective flow area. METHODS AND RESULTS: Laser flow imaging was used to visualize the contraction in the jet flow stream as it passed through bileaflet mechanical valves under steady and pulsatile conditions. Such visualization allowed clear measurement of the individual vena contracta areas (VCAs) of the 3 valve orifices. VCAs for side orifices were larger (94+/-2% of AOA) than those through the central orifice (34+/-8%). Formation of large radial vortices around the leaflet tips constricted the central orifice flow stream and appeared to be the main reason for smaller central VCA. Total VCA remained constant until approximately 0.5 orifice diameters ( approximately 1.0 cm) downstream, beyond which cross-sectional area increased as a result of entrainment of receiving chamber flow. Total VCA was larger for steady flow (89.6+/-2.7% of AOA) than for pulsatile flow (76.3+/-5.0% of AOA). CONCLUSIONS: This study further clarifies flow dynamics through bileaflet mechanical valves and provides previously unavailable reference information on VCAs for these valves. Such information should aid clinicians in explaining Doppler-derived and catheter-measured pressure discrepancies, validating clinical techniques for quantifying effective flow areas, and optimizing valve size for implantation. The method should also be useful for comparative studies of different valve designs.

Echocardiography↗

Utility of the proximal jet width in the assessment of regurgitant and stenotic orifices--effect of low velocity filter and comparison to actual vena contracta width: an in vitro and numerical study.

AIM: The colour Doppler proximal jet width (CDPJW) has been shown to be directly related to the severity of regurgitant and stenotic valve lesions. It is generally assumed that the CDPJW is equivalent to the vena contracta width (VCW). The purpose of this numerical and in vitro study was to evaluate how changing low velocity filter (LVF) settings on colour Doppler imaging devices may affect the CDPJW and its estimate of the VCW. METHODS: Computational fluid dynamic software was used to create models of round orifices (0.785, 1.13, 1.76, 3.14 cm2) at set flow rates (0.37-25 1/min). In vitro experiments were performed with round orifices (0.2, 0.95 and 1.76 cm2) with set flow rates (1.8-3.6 1/min). Laser flow visualization was used to obtain gold standard vena contracta widths for comparison to CDPJW for various LVF settings (4-24 cm/s). RESULTS: With the LVF set 'too low', overestimation errors occur. In contrast, with the LVF set 'too high', underestimation errors occur. Optimal LVF settings are required to avoid over- and underestimation errors of up to 280%. SUMMARY: The VCW is related to regurgitant or stenotic lesion severity, and the CDPJW is an approximation of the VCW. The CDPJW closely resembles the actual VCW only at optimally chosen LVF settings. LVF settings can have a significant impact on the accuracy of the CDPJW. Inter mediate filter settings remove unnecessary background noise while maintaining actual flow regions, thereby providing the best agreement between the CDPJW and the VCW. If treatment decisions are to be based on these measurements, understanding such dependencies becomes quite important.

Blood Flow Velocity↗

Three-dimensional imaging of aortic arch anomalies in infants and children with intravascular ultrasound catheters from a transesophageal approach.

Aortic arch anomalies usually require surgical intervention preceded by precise anatomic definition. We studied 20 patients to evaluate the feasibility and accuracy of using intravascular ultrasound catheters from a transesophageal approach with 3-dimensional image reconstruction for the diagnosis of aortic arch anomalies in infants and children. All patients had transthoracic echocardiograms and/or angiograms or magnetic resonance imaging. A 12.5-MHz intravascular ultrasound catheter was positioned in the esophagus and withdrawn by using an electrocardiogram and a respiratory gated pullback device to acquire the mediastinal images. All patients with arch anomalies underwent surgical repair. Reconstructed images were analyzed in the "anyplane" mode and with surface rendering. Intravascular ultrasound 3-dimensional imaging was successfully accomplished without complications. Anatomy was correctly identified in all patients by both blinded and unblinded observers, thus confirming the sensitivity and accuracy of the technique. We foresee this new technique to be useful as an adjunctive imaging modality applicable at the bedside or in the cardiac imaging laboratory.

Aorta, Thoracic↗

Real-time 3-dimensional volumetric ultrasound imaging of the vena contracta for stenotic valves with the use of echocardiographic contrast imaging: in vitro pulsatile flow studies.

The purpose of our study was to investigate the utility of real-time 3-dimensional volumetric ultrasound coupled with echo contrast imaging to visualize and quantify effective flow areas for stenotic valves in vitro. Real-time 3-dimensional ultrasound imaging has recently emerged as a promising method for increasing the quantitative accuracy of echocardiography. Since the technique currently does not process Doppler information, its use for quantifying flow has not been studied. However, the use of contrast agents to visualize cardiac flows with the use of echocardiography should allow determination of mass-dependent flow parameters such as effective flow area (vena contracta area) for stenotic lesions. We used real-time 3-dimensional imaging in an in vitro stenotic valve model (areas 0.785 to 1.767 cm2) under pulsatile flow conditions (60 bpm; 40 to 80 mL/beat). An echo contrast agent was used to visualize the distal jet. Real-time 3-dimensional imaging provides simultaneous views of long-axis and short-axis (C-scan) image planes of the jet. The vena contracta was identified and measured by placing the C-scan line immediately distal to the orifice and measuring the cross-sectional flow area. System gain and postprocessing curve shape affected 3-dimensional areas; minimal gain and a custom curve produced best agreement to actual vena contracta areas measured with a previously validated laser method (y = 0.939x + 0.089; r = 0.98; standard error of estimate = 0.158 cm2). We conclude that real-time 3-dimensional ultrasound imaging coupled with a contrast agent can be used as an accurate yet simple clinical means of measuring effective flow areas for stenotic valves.

Albumins↗

Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculations: a numerical study.

BACKGROUND: Flow-rate dependencies of the Doppler continuity equation are addressed in this study. METHODS AND RESULTS: By use of computational fluid dynamic (CFD) software with turbulence modeling, three-dimensional axisymmetric models of round stenotic orifices were created. Flow simulations were run for various orifice area sizes (0.785, 1.13, 1.76, and 3.14 cm2) and flow rates (0.37 to 25.0 L/min). Reynolds numbers ranged from 100 to 8000. Once adequate convergence was obtained with each simulation, the location of the vena contracta was determined. For each run, maximum and average velocities across the cross section of the vena contracta were tabulated and vena contracta cross-sectional area (effective orifice area) determined. The difference between the maximum velocity and the average velocity at the vena contracta was smallest at high-flow states, with more of a difference at low-flow states. At lower-flow states, the velocity vector profile at the vena contracta was parabolic, whereas at high-flow states, the profile became more flattened. Also, the effective orifice area (vena contracta cross-sectional area) varied with flow rate. At moderate-flow states, the effective orifice area reached a minimum and expanded at low- and high-flow states, remaining relatively constant at high-flow states. CONCLUSIONS: We have shown that significant differences exist between the maximum velocity and the average velocity at the vena contracta at low flow rates. A likely explanation for this is that viscous effects cause lower velocities at the edges of the vena contracta at low flow rates, resulting in a parabolic profile. At higher-flow states, inertial forces overcome viscous drag, causing a flatter profile. Effective orifice area itself varies with flow rate as well, with the smallest areas seen at moderate-flow states. These flow-dependent factors lead to flow rate-dependent errors in the Doppler continuity equation. Our results have strong relevance to clinical measurements of stenotic valve areas by use of the Doppler continuity equation under varying cardiac output conditions.

Animals↗

Intravascular ultrasonic characteristics and vasoreactivity of the pulmonary vasculature in children with pulmonary hypertension.

We sought to describe the morphologic characteristics of pulmonary arteries by intravascular ultrasound (IVUS) in children with and without pulmonary hypertension to compare these anatomic findings with those of pulmonary wedge angiography, and to determine the relation between these structural findings and functional reactivity to pulmonary vasodilators. Direct evaluation of pulmonary vascular structure in children with pulmonary hypertension with current imaging techniques has been limited and little is known about the relation between structural and functional characteristics of the pulmonary vasculature. In 23 children undergoing cardiac catheterization (15 with pulmonary hypertension and 8 controls) we performed IVUS and pulmonary wedge angiography of the distal pulmonary arteries in the same lobe. IVUS was performed in 44 pulmonary arteries measuring 2.5 to 5.0 mm internal diameter with a 3.5Fr 30-MHz IVUS catheter. We assessed vasoreactivity to inhaled nitric oxide (NO) and oxygen in 13 of 15 children with pulmonary hypertension. Baseline pulmonary vascular resistance (PVR) was greater in the 15 children with pulmonary hypertension than in the 8 controls (9.5+/-1.9 vs 1.5+/-0.3 U x m2, p <0.05). NO lowered PVR in patients with pulmonary hypertension (p <0.05). IVUS studies in patients with pulmonary hypertension showed a thicker middle layer, wall thickness ratio, and diminished pulsatility than did those in controls (p <0.05). The inner layer was not visualized by IVUS in any control patient, but was seen in 9 of 15 patients with pulmonary hypertension. Pulmonary artery wedge angiography correlated with baseline mean pulmonary artery pressure and PVR as well as with IVUS findings of wall thickness ratio and inner layer thickness. The inner layer was not visualized by IVUS in any patient with grade 1 wedge angiograms or in 86% of patients with grade 2 wedge angiograms. All patients with grade 4 and 80% of patients with grade 3 wedge angiograms had a visible inner layer. Vasoreactivity to NO and oxygen did not correlate with structural assessment of the pulmonary vasculature by IVUS. Structural changes in the pulmonary arteries in children with pulmonary hypertension can be directly visualized by IVUS, but are not predictive of NO-induced pulmonary vasodilation. IVUS examination of pulmonary arteries may complement current techniques utilized in the evaluation of children with pulmonary hypertension.

Administration, Inhalation↗

Utility of three-dimensional ultrasound Doppler flow reconstruction of the proximal jet to quantify effective orifice area: in vitro steady and pulsatile flow studies.

We examined the utility of three-dimensional (3D) reconstruction of two-dimensional color Doppler images of the proximal jet to quantify the effective area of an orifice in an in vitro model. Steady and pulsatile flows were directed through various orifices; orifice vena contracta areas were quantified with laser flow visualization, thus providing gold standard effective orifice areas. Three-dimensional areas followed vena contracta areas well, although variations in color Doppler gain and 3D gray levels for thresholding produced significant changes in reconstructed images. These variations were minimized by using minimum color gain and 50% gray level threshold. At these settings, 3D areas still overestimated vena contracta areas by approximately 25% because of the poor lateral resolution of the color Doppler system, which caused bleeding of the flow signal past the edges of the proximal jet. Nevertheless, 3D flow images provided a superior format for qualitative and quantitative appreciation of proximal jet shape and dimensions.

Heart Valve Diseases↗

Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation: a comparative in vitro study.

To study the effects of flow acceleration and high-velocity jets on the display characteristics of cine magnetic resonance imaging compared with color Doppler flow mapping, a custom-designed in vitro flow model was developed. This model consisted of a funnel segment tapering to an orifice (0.78 cm2) that leads into a confined receiving chamber with a second, discrete orifice (0.78 cm2) at its distal end. Cine magnetic resonance images obtained at varying flow rates (1.5 to 27.2 L/min) demonstrated loss of signal intensity throughout the tapering zone of spatial acceleration and a small zone of more marked signal loss immediately proximal to the second orifice (always < 50% of the signal intensity within the tapering funnel zone) associated with more rapid spatial acceleration. A formed jet was imaged distal to the first orifice, and the turbulence area surrounding the laminar central jet core correlated well with flow rate (r = 0.98), as did the distance from the orifice to the subsequent onset of flow relaminarization (r = 0.96). A turbulent spray area was always seen distal to the second, discrete orifice. Comparative observations with color Doppler flow mapping and continuous wave Doppler demonstrated that signal intensity on cine magnetic resonance imaging is reduced by both spatial acceleration, and the high-velocity and turbulent jets associated with obstructive and regurgitant lesions. In vitro evaluation of cine magnetic resonance imaging allows comparative observations to be made about the flow characteristics of cine magnetic resonance imaging and color Doppler flow mapping and provides a more rational basis for the interpretation of cine magnetic resonance imaging in the clinical setting.

Blood Flow Velocity↗

Effects of pressure and volume of the receiving chamber on the spatial distribution of regurgitant jets as imaged by color Doppler flow mapping. An in vitro study.

Regurgitant jet dimensions imaged by color Doppler flow mapping have been used to evaluate the severity of valvular insufficiency in clinical studies. To study the effect of pressure and volume within the receiving chamber on the magnitude of spatial distribution of regurgitant jets assessed by color Doppler techniques, we designed a simple constant-flow model in which a jet was driven through a known orifice (1.5 mm2) into a compliant receiving chamber by a steady-flow pump. A distal tube at the outflow closed the system and maintained the volume of the chamber constant during pump operation. We varied flow rate from 60 to 270 ml/min into elastic balloons with different static compliances of 1, 2, 4.5, and 9 ml/mm Hg (pressures of 57, 28, 18, and 8 mm Hg, respectively); the balloons served as receiving chambers at the constant volume of 150 ml. We also evaluated the effect of different volumes of a receiving chamber (110, 130, and 150 ml and pressures of 5, 15, and 24 mm Hg) with a static compliance of 2 ml/mm Hg over the same range of flow rates. For each of the different balloons, jet area correlated linearly with the jet velocity across the orifice (r = 0.98, 0.99, 0.98, and 0.97) and also with flow rate (r = 0.97, 0.99, 0.98, and 0.99). At the same flow rate and volume of receiving chamber, however, the jet area imaged by color Doppler decreased as the pressure in the receiving chamber increased, although receiving-chamber volume was constant.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity↗

Endomyocardial biopsy with fluoroscopic and two-dimensional echocardiographic guidance: case report of a patient suspected of having multiple cardiac tumors.

An 18-year-old female with multiple intracardiac masses was further evaluated using percutaneous endomyocardial biopsy of the right ventricle and right atrium. Fluoroscopy was used to visualize the course of the bioptome and simultaneous two-dimensional echocardiography was used to image the masses thus improving the surgeon's chance of obtaining diagnostic tissue.

Adolescent↗

Cross-sectional echocardiographic diagnosis and subclassification of univentricular hearts: imaging studies of atrioventricular valves, septal structures and rudimentary outflow chambers.

We reviewed anatomic observations (surgical or autopsy), angiograms and echocardiograms from 44 patients with documented univentricular hearts. Thirty-three patients had univentricular heart of left ventricular type with an outflow or rudimentary chamber. Five had univentricular heart of right ventricular type, and six had univentricular heart of indeterminate types without a rudimentary chamber. Univentricular heart was correctly diagnosed by two-dimensional echocardiography in all but two of the 44 patients, including 25 of 27 double-inlet univentricular hearts, all five with absent left and all 12 with absent right atrioventricular connection. One of the two blind trabecular pouches was missed on echocardiography; the other was not seen on the angiogram but was present at autopsy. In 30 of 33 patients, univentricular heart of left ventricular type was correctly identified by imaging an anterosuperior and leftward or rightward outlet chamber, and in four of five patients with univentricular heart of right ventricular type, the anomaly was correctly identified by imaging the inferior and posterior position of the rudimentary outflow chamber near the crux of the heart. Two-dimensional echocardiography provides detailed analysis of atrioventricular connections, main chamber morphology, and rudimentary chamber size and position of noninvasive diagnosis and anatomic subclassification of univentricular hearts.