Extracorporeal liver perfusion using human and pig livers for acute liver failure.

BACKGROUND: Patients with fulminant hepatic failure (FHF) often die awaiting liver transplantation. Extracorporeal liver perfusion (ECLP) has been proposed as a method of "bridging" such patients to transplantation. We report the largest experience to date of ECLP using human and porcine livers in patients with acute liver failure. METHODS: Patients with FHF unlikely to survive without liver transplantation were identified. ECLP was performed with human or porcine livers. Patients underwent continuous perfusion until liver transplantation or withdrawal of support. Two perfusion circuits were used: direct perfusion of patient blood through the extracorporeal liver and indirect perfusion with a plasma filter between the patient and the liver. FINDINGS: Fourteen patients were treated with 16 livers in 18 perfusion circuits. Nine patients were successfully "bridged" to transplantation. ECLP stabilized intracranial pressure (ICP) and cerebral perfusion pressure (CPP). Arterial ammonia levels fell from a median of 146 to 83 micromol/liter within 12 hr and this reduction was maintained at least 48 hr. Pig and human ECLP lowered ammonia levels equally. Serum bilirubin levels also fell from a median of 385 to 198 micromol/liter over the first 12 hr but the response was not sustained as well with porcine livers. There was no immunological benefit to using the the filtered perfusion circuit. INTERPRETATION: These data demonstrate that ECLP is safe and can provide metabolic support for comatose patients with fulminant hepatic failure for up to 5 days. While labor and resource intensive, this technology is available to centers caring for patients with acute liver failure and deserves wider evaluation and application.

Adolescent↗

Removal of hepatocarcinoma cells from blood via cell washing and filtration techniques.

Utilization of autotransfusion during tumor resection remains controversial due to viability of carcinoma cells remaining in collected blood. The purpose of this study was to evaluate autotransfusion techniques combined with leukocyte depleting filters (LDF) for removal of hepatocarcinoma cells from autotransfusate. An in vitro model was created by contaminating expired human erythrocytes with cultured hepatocarcinoma (HEP G2) cells. Autotransfusion devices evaluated were Cobe BRAT2, Sorin STAT-P, and Fresenius CATS. Autotransfusate collected from varying processing conditions were filtered using the Pall Leukoguard RS or Pall Purecell RCQ LDF. Carcinoma concentrations were quantified via Coulter Counter technology. The CATS exhibited higher concentrations of cancer cells in the autotransfusate prior to washing, a 449% increase. This was significantly higher than either the BRAT2 or STAT-P, 350% and 315% respectively. Post washing HEP G2 concentrations in the BRAT2 were significantly higher than the STAT-P and CATS. Doubled wash volumes removed more HEP G2 cells in all trials, reaching statistical significance only in the CATS. LDF resulted in a significant 75% reduction of HEP G2 cells, with no difference between filters. While combination use of autotransfusion devices and leukocyte depleting filters did result in a product with concentrated hematocrit, no technique removed all hepatocarcinoma cells.

Blood Transfusion, Autologous↗

Clinical evaluation of a new generation membrane oxygenator: a prospective randomized study.

A new generation hollow-fibre membrane oxygenator (Spiral Gold) has been introduced by Baxter Healthcare (Irvine, CA, USA). The purpose of this study was to evaluate the operational performance of this device under clinical conditions and to compare it to the Univox Gold membrane oxygenator. Following institutional review board approval, and the obtainment of informed consent, 26 patients undergoing coronary artery bypass grafting were randomly assigned to either a Spiral Gold (Spiral) (n = 13) or Univox Gold (Univox) (n = 13) group. Study parameters were grouped into the following categories: haematological, haemodynamic, oxygenator performance and perioperative outcomes. All patients received identical surgical, anaesthesia and postoperative care. There were no statistically significant differences in either preoperative or operative parameters between groups. During cardiopulmonary bypass, the Spiral group had a significantly lower pressure drop (26.9 +/- 8.2 vs 46.7 +/- 16.2 mmHg, p < 0.001). The Spiral group had significantly lower plasma free haemoglobin levels during all time periods of CPB compared to the Univox group. Heat exchange coefficients were higher during the rewarming period in the Spiral patients (0.59 +/- 0.28) compared to the Univox group (0.36 +/- 0.19), p = 0.06. There were no differences in oxygen transfer between groups, but ventilation gas sweep rates and FiO2 levels were statistically lower in the Spiral group at two of the three sampling time periods. The ratio of ventilating gas sweep rate to blood flow rate was lower in the Spiral group (0.56 +/- 0.12) compared to the Univox group (0.74 +/- 0.23), p < 0.03. The Spiral Gold oxygenator had superior oxygen transfer efficiency and lower haemolysis rates than the Univox Gold oxygenator.

Adult↗

Clinical evaluation of a new in-line continuous blood gas monitor.

Two methodologies for obtaining accurate blood gas and electrolyte values during cardiopulmonary bypass (CPB) are traditional laboratory analyzers, which use an electrochemical technology, and continuous in-line monitoring systems, which use a fluorometric and/or spectrophotometric technology. The purpose of the present study was to evaluate the accuracy of a new continuous in-line monitor, the 3M CDI Blood Parameter Monitoring System 500, which provides continuous in-line measurements of pH, PCO2, PO2, potassium (K+), oxygen saturation, hematocrit, hemoglobin, and temperature, during partial or complete CPB. Study parameters included arterial pH, PCO2, PO2, and K+ values. Overall performance was analyzed by calculating the mean difference (expressed as the bias) between the CDI system 500 and the laboratory analyzer for each parameter. The accuracy of the arterial pH, PCO2, and K+ values provided by the CDI system 500 was then evaluated using target values established in the acceptable performance standards for laboratory analyzers from the Clinical Laboratory Improvement Act of 1988 (CLIA '88). The accuracy of the PO2 value provided by the CDI system 500 was evaluated using a target value of +/- 10% of the reference, or laboratory analyzer, value. A prospective multi-center trial was conducted following Institutional Review Board approval. A total of 75 cases was included in the analyses, with over 200 data points from 4 clinical locations. Results for pH, PCO2, and K+ were within the target values established by CLIA '88. pH bias was 0.00 +/- 0.02 pH units. PCO2 bias was -0.3 +/- 3.3 mm Hg. K+ bias was approximately +0.12 +/- 0.31 mmole/l. Results for PO2 were within 10% of the reference value. PO2 bias was 7.5 +/- 13.8 mm Hg. The results of this clinical trial show that the CDI System 500 continuous in-line monitoring system provides values that meet the accuracy standards for laboratory analyzers for arterial pH, PCO2, PO2, and K+.

Bias↗

Coagulopathic-induced membrane dysfunction during extracorporeal membrane oxygenation: a case report.

This paper describes an unusual complication of membrane dysfunction during extracorporeal membrane oxygenation (ECMO) for treatment of neonatal respiratory distress. A 2.8-kg term infant presented to our facility in severe respiratory distress and was diagnosed with primary pulmonary hypertension. After routine priming of the extracorporeal circuit, the patient was placed on veno-arterial ECMO with 8 F arterial and 12 F venous cannulae. Transfusion criteria were established which included trigger values of the following: platelet count 100,000/microliters, fibrinogen 150 mg/dl, haematocrit 40%. The ECMO course was uneventful until approximately the 132nd hour on support when the patient developed a consumptive coagulopathy, as evidenced by 55-60% reductions in both platelet count and fibrinogen concentrations, despite transfusion therapy. Total autogeneic blood product transfusion during the first 120 h of ECMO averaged 4.4 +/- 2.2 ml/h, while the transfusion rate for the final 35 h was 7.8 +/- 3.5 ml/h. Coinciding with this rise in transfusion requirements was an increase in transmembrane pressure from 0.29 to 1.52 mmHg/ml blood flow. The patient was separated from ECMO after 175 h due to a continuing coagulopathy and haemothorax. The patient was then treated with nitric oxide therapy before succumbing on the twelfth postoperative day due to refractory respiratory failure. The circuit was dissected and significant clots found in both the venous bladder and oxygenator. In addition, approximately one-third of the membrane compartment had a 'fused' circumferential pattern of dessicated clot which interrupted blood path continuity. In conclusion, this report describes an unusual complication of the ECMO oxygenator that occurred during long-term extracorporeal life support which most likely resulted from a coagulopathy.

Blood Transfusion↗

Extracorporeal support with a cadaver liver as a bridge to transplantation.

Extracorporeal liver perfusion (ECLP) has been used for detoxifying blood in patients in class IV hepatic encephalopathy. Palliation of the moribund patient utilizing extracorporeal devices with cross-circulation of a cadaver liver has been documented for over three decades. Common problems associated with this procedure which appear in the literature include cadaver liver distention, increased resistance to blood flow, and limited time of extracorporeal support due to cadaver liver failure. This report summarizes the experiences of the perfusion team in utilizing an extracorporeal circuit with an otherwise nontransplantable cadaveric liver, to support the decompensating hepatic patient as a bridge to transplantation. Between January and July 1992, three patients were supported for hepatic failure with ECLP. Two patients were placed on ECLP with a modified circuit containing two positive displacement pumps and one centrifugal pump. The third patient was placed on ECLP with a circuit that contained two centrifugal pumps and one positive displacement pump. Patient age ranged from 6 to 38 years and length of support ranged from 24 to 72 hours. In all three patients, a centrifugal pump was placed in the suprahepatic inferior vena cava line to facilitate cadaver liver drainage and decompression. Intensive monitoring of both patient and cadaver liver hemodynamics, hepatic function, and hematological status was performed. All three patients were successfully weaned from ECLP. Two patients received successful orthotopic liver transplantation. The third died of complications unrelated to ECLP after support was discontinued.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Successful application of extracorporeal liver perfusion: a technology whose time has come.

We have used extracorporeal liver perfusion (ECLP) to aid in the management of three patients with fulminant hepatic failure (FHF). Organs were used for ECLP only if they would have gone otherwise unused through United Network for Organ Sharing. In all three patients treated, serial serum bilirubin and arterial ammonia values trended toward the normal range. The neurologic examinations improved dramatically in two patients, and metabolic function of the extracorporeally perfused livers was unequivocally demonstrated by the clearance of theophylline in the last two patients. Two patients ultimately had successful liver transplants, whereas the third patient failed to improve neurologically despite evidence of metabolic function by the extracorporeally perfused liver, and died 7 days after ECLP was discontinued, from pulmonary and renal failure. These studies suggest that, 30 yr after initial clinical trials, ECLP can be applied safely without the need for arterial access 1) as a bridge to transplantation, 2) to assess whether patients in FHF will benefit from improved hepatic function and therefore transplantation, and 3) potentially, to evaluate the "usability" of questionable donor organs.

Adolescent↗