PubMed Health⌕ Search

Biomedical subjects

L W Hedlund

Publications and source records attributed to L W Hedlund.

At least 73 records · Page 4Linked to original sources

Implanted coil MR microscopy of renal pathology.

Inductively coupled implanted coils have been shown to provide up to a 10-fold increase in signal-to-noise ratio when compared to whole-body imaging of small animals. The current study was designed to extend the implanted coil imaging technique to a rodent model of renal pathology. Resonant radiofrequency (RF) coils were implanted around the left kidney of four rats and inductively coupled from within a birdcage body coil. All images were acquired at 2 T using a T1-weighted spin-echo sequence with TR = 500 ms and TE = 20 ms. In vivo MR microscopy with voxels of 117 x 117 x 2000 microns demonstrated cortex, inner and outer medulla, and major vascular structures on baseline images. Mercuric chloride-induced nephrotoxic acute tubular necrosis (ATN) diminished cortico-medullary contrast at 24 h after dosing with pathologic evaluation demonstrating nephrotoxic changes in the inner cortex. The kidney regained a baseline MR appearance 360 h after dosing and resolution of the damage was confirmed with histology. T1 data were gathered on excised kidneys as an adjunct to the images to help correlate the loss and return of cortico-medullary contrast with the pathology and pathophysiology of nephrotoxic ATN. With implanted RF coils we were able to demonstrate renal pathology and follow its subsequent resolution. Specifically, loss and return of cortico-medullary contrast as a result of nephrotoxic ATN were serially documented in four rats. Such serial in vivo studies performed on single animals should further the use of MR microscopy by minimizing the number of animals required for adequate biostatistics.

Animals↗

Evaluation of flow through simulated vascular stenoses with gradient echo magnetic resonance imaging.

Magnetic resonance imaging using gradient echo sequences can quickly generate dynamic images of the cardiovascular system. We used a gradient echo sequence (repetition time = 21 milliseconds, echo time = 12 milliseconds, flip angle = 30 degrees) to evaluate how a simulated vascular stenoses affects the signal intensity of flowing fluid. Axial slices were obtained at regular intervals along a plastic tube containing a circular constriction (25%, 51%, or 73% reduction of cross-sectional area). Image data collected at each slice level were used to reconstruct 32 images evenly spaced in time over one cycle of pulsatile flow. Contrast ratios were calculated between signal intensities from tube lumen and surrounding stationary water jacket. Upstream from each stenosis, signal intensity increased during systole and decreased during diastole, paralleling the changes in velocity we measured with a flow probe. However, within the 51% and 73% stenoses and just beyond them, there were consistent decreases in systolic signal intensity. Flow through the 25% constriction had little effect on the signal intensity pattern. These results suggest that the gradient echo pulse sequence may be useful in evaluating disturbed flow associated with vascular stenoses.

Arterial Occlusive Diseases↗

Fast limited flip angle MR subtraction angiography.

A fast MR angiography method is introduced that is capable of generating difference images of blood vessels in scan times of 10-20 s. This is an order of magnitude faster than many previous methods. The fundamental concept of this approach is to use cardiac gating and acquire several phase encodings at least twice during each cardiac cycle using limited flip angles (LFAs) and repetition times in the 20 to 50 ms range. The encodings acquired during diastole are subtracted from those acquired during systole to generate the difference image. The contrast in the difference image is due both to the influx of unsaturated spins and to the loss of phase coherence of systolic blood moving at high velocity along a magnetic gradient. The systolic peak of the cardiac cycle is determined during reconstruction by shifting the systolic and diastolic "windows" until the difference signal is maximized. Ghost artifacts due to pulsatile flow are eliminated by a phase reordering technique similar in concept to those developed for suppression of breathing artifacts. Arteries in thick slices are successfully imaged and initial in vivo results are presented.

Angiography↗

Effects of turbulence on signal intensity in gradient echo images.

Although the appearance of laminar vascular flow in magnetic resonance (MR) images has been characterized, there is no general agreement about the effect of turbulent flow on MR signal intensity. This study uses a fast scan gradient echo pulse sequence to evaluate nonpulsatile turbulent flow in two different models. The first model simulated flow in normal vascular structure. It generated nonpulsatile, laminar and turbulent flow in straight, smooth-walled Plexiglas tubes. The second model simulated flow through a vascular stenosis. It generated nonpulsatile, laminar, and turbulent flow through an orifice. Velocities and flow rates ranged from low physiologic to well above the physiologic range (velocity = .3 to 280 cm/second, flow rate from .15 to 40 L/minute). Transition from laminar to turbulent flow was observed with dye streams. Turbulent flow in straight, smooth-walled vessels was not associated with a decrease in MR signal intensity even at the highest velocities and flow rates studied. The transition from laminar to turbulent flow through an orifice is not associated with a decrease in gradient echo signal intensity. As the intensity of the turbulent flow increases, however, there is a threshold above which signal intensity decreases linearly as turbulence increases (r = .97). This study suggests that flow in normal vascular structures should not be associated with decreased signal intensity in gradient echo images. Turbulent flow through areas such as valves, valvular lesions or vascular stenoses, may be associated with a decrease in gradient echo signal intensity.

Blood Flow Velocity↗

A cardiac phantom and pulsatile flow pump for magnetic resonance imaging studies.

Fast scan magnetic resonance imaging (MRI) acquisitions are a rapid noninvasive means of evaluating the cardiovascular system. Because the appearance of flowing blood is highly variable, the interpretation of these images is sometimes difficult. A nonferromagnetic phantom that could generate lifelike pulsatile flow and also simulate the motions of the beating heart would facilitate image interpretation. This paper describes an MRI-compatible cardiovascular phantom that mimics the motions of the heart and also creates physiologic pulsatile flow. The phantom consists of a ventricle and an air pump that drives it. The pump is connected to the ventricle with seven meters of air hose so that the pump (which has ferromagnetic parts) can be placed outside the magnet room. The ventricle is placed in an airtight Plexiglas cylinder and the pump alternately pressurizes and depressurizes the cylinder, driving fluid in and out of the ventricle. The motions of the ventricular wall simulate the motions of the heart, and the pulsatile flow generated is of physiologic velocities and volumes. This phantom also can be used with other methods of evaluating cardiovascular function, such as MUGAS, angiography, and Doppler, allowing correlation between MRI and other modalities. Finally, the phantom can be used to study almost any aspect of cardiovascular function from pulsatile flow velocity to ventricular studies (ejection fractions, cardiac output, wall motion) and even studies of stenotic or regurgitant valves.

Heart↗

Magnetic resonance imaging (MRI): a new tool in experimental toxicologic pathology.

Magnetic Resonance Imaging (MRI) is a noninvasive imaging technique that provides multidimensional images of the soft tissues of the body. This imaging technique has proven to be an excellent diagnostic and experimental tool for the detection of pathologic alterations in soft tissues, as well as an adjunct screening method for following the genesis, progression, or regression of chemically induced lesions in the same live animal. Future applications of MRI technology in small animals include MRI microscopy, mapping of vascular or circulatory alterations, measurement of perfusion and diffusion rates of body fluids, and acquisition of cell metabolic states in combination with Nuclear Magnetic Resonance (NMR) spectroscopy, all of which will contribute immensely to the advancement of toxicologic and biomolecular research.

Animals↗

The fate of inorganic phosphate and pH in regional myocardial ischemia and infarction: a noninvasive 31P NMR study.

To determine the characteristic appearance of phosphorus (31P) nuclear magnetic resonance spectra in acute and chronic myocardial infarction in situ, cardiac-gated depth-resolved surface coil spectroscopy (DRESS) at 1.5 T was used to monitor 31P NMR spectra from localized volumes in the left anterior canine myocardium for up to 5 days following permanent occlusion of the left anterior descending coronary artery. Coronary occlusion initially produced regional ischemia manifested as significant reductions in the phosphocreatine (PCr) to inorganic phosphate (Pi) ratios and intracellular pH (P less than 0.05, Student's t test) in endocardially displaced spectra acquired in periods as short as 50 to 150 s postocclusion. Spectra acquired subsequently revealed either (i) restoration of near-normal phosphate metabolism sometime between 10 and about 50 min postocclusion or (ii) advancing ischemic phosphate metabolism at about an hour postocclusion, and/or (iii) maintenance of depressed PCr/Pi ratios for up to 5 days postocclusion with a return of the apparent pH to near normal values between 6 and 15 h postocclusion. Postmortem examination of animals exhibiting the first type of behavior revealed the existence of coronary collateral vessels. The last type of behavior indicates that Pi remains substantially localized in damaged myocardium for days following infarction. The location and size of infarctions were determined postmortem by staining excised hearts. The smallest infarctions detected by 31P DRESS weighed 4.9 and 7.5 g. The most acidic pH measured in vivo was 5.9 +/- 0.2. Infarctions aged 1/2 day to 5 days were characterized by elevated but broad Pi resonances at 5.1 +/- 0.2 ppm relative to PCr and significantly depressed PCr/Pi ratios (P less than 0.002, Student's t test) relative to preocclusion values. Contamination of Pi resonances by phosphomonoester (PM) components is a significant problem for preocclusion Pi and pH measurements. These results should be applicable to the detection and identification of human myocardial infarction using 31P NMR and DRESS.

Adenosine Triphosphate↗

Evaluation of steady and pulsatile flow with dynamic MRI using limited flip angles and gradient refocused echoes.

Magnetic resonance imaging sequences utilizing limited flip angles and gradient echoes yield rapid (less than 2 min) dynamic images of the cardiovascular system. These images contain both accurate anatomical and functional information. Using a gradient refocused acquisition in the steady state (GRASS) in the CINE mode, we studied the relationship between gradient echo signal intensity and velocity of steady and pulsatile flow in a phantom simulating medium to large vessels. Images were acquired on a 1.5 Tesla system (repetition time = 21 ms, echo time = 12 ms, flip angle = 30 degrees). Data from each pulse interval were sorted in 16 images. Signal intensities from flow tube lumina and surrounding stationary water jacket were used to calculate contrast ratios which were compared to velocity measurements made with electromagnetic (EM) flow probes outside the magnet room. During steady flow, signal intensity contrast ratios increased with increasing flow and in a 10 mm thick slice, reached a peak at 48 cm/s, and declined for velocities up to 90 cm/s. Changes in instantaneous velocity during pulsatile flow correlated well (r greater than .88) with signal intensity changes up to a maximum mean velocity of 17 cm/s. Total signal intensity from the lumen for an "R to R" interval correlated extremely well (r greater than .97) with mean pulsatile flow velocities up to 30 cm/s. The excellent correlation between gradient echo signal intensity and actual flow velocities suggests that this imaging sequence might be useful for evaluating normal and pathologic flow phenomena.

Blood Circulation↗

Optimizing electrocardiograph electrode placement for cardiac-gated magnetic resonance imaging.

Electrocardiographs recorded in a magnetic field for cardiac-gating in magnetic resonance imaging (MRI) are complicated by blood flow-induced potentials. This study examines which lead of the standard 12-lead ECG maximizes the QRS while minimizing flow-induced interference. Twelve-lead ECGs were performed on normal volunteers (n = 9) and patients (n = 13) in and out of the bore of a 1.5 Tesla imaging magnet. The amplitude of the major flow-induced potentials was measured, and the vectors of largest induced potential and the QRS axis were plotted for each subject. ECGs obtained outside and inside the magnet were digitized and subtracted (in magnet ECG--out of magnet ECG = artifact ECG) and the peaks of the resultant curves measured. Superimposed potentials were largest in the early T wave and late S-T segment in leads I, II, V1, and V2, and smallest in III and AVF. A low-amplitude 7-to 10-Hz signal occurred in most leads. In the frontal plane, QRS axes and flow potential vectors were closely clustered. In the transverse plane, QRS axes generally followed leads V5 or V6, whereas the flow potential vectors followed leads V1, V2, or V3. The normal and patient groups did not differ. Although leads III and AVP showed the smallest superimposed potentials, V5, V6, or a left posterior chest lead may maximize QRS and reduce artifact most consistently. A 7- to 10-Hz frequency filter may help eliminate artifacts in some subjects.

Blood Flow Velocity↗

Contrast enhancement of the liver. Evaluation by automated contiguous pixel search.

Eight dogs were infused with one of three different contrast agents: meglumine diatrizoate, iosulamide meglumine, or an ethiodized oil emulsion (EOE 13). Image intensity in the liver was evaluated globally and regionally by means of an automated pixel sampling method to determine differences in the rate of enhancement produced by the three agents. The results of the automated method were compared with those of the standard manual cursor method. The automated method showed that liver parenchyma was enhanced uniformly by all three contrast agents. The maximum degree of enhancement (Mean +/- SEM) for the three agents was diatrizoate, 12.0 +/- 3.5 Hounsfield units (HU); iosluamide, 21.3 +/- 3.5 HU; and EOE 13, 37.2 +/- 4.25 HU. With the manual cursor method, contrast enhancement was about 20% more than estimated by the automated method. The automated method is better for evaluating the magnitude and pattern of contrast agent enhancement of the entire liver, since the currently employed cursor technique requires multiple evaluations to evaluate the entire liver.

Animals↗

Work in progress: in vitro analysis of pleural fluid analogs by proton magnetic resonance. Preliminary studies at 1.5T.

To test the potential of 1.5 Tesla magnetic resonance imaging (MRI) for assessing the protein concentration of pleural effusions, five pleural fluid analogs (saline + 0, 2, 4, 6, 8 g albumin/100 mL) and, for comparison, four saline dilutions of whole blood were evaluated in vitro. The relaxation rates (1/T1, 1/T2) of albumin solutions were determined by 1.5 T spectroscopy (MRS) and correlated with albumin concentration (1/T1:slope 0.02, r + 0.89, P less than .05; 1/T2: slope 0.16, r = 0.997, P less than .001). MRI studies of these solutions showed no significant correlation with 1/T1, but 1/T2 showed a positive correlation with albumin concentration (r = 0.98, P less than .01). Both MRI relaxation rates were significantly correlated with blood concentration, and slopes were greater than for albumin solutions. These preliminary studies, demonstrating differences in correlation between relaxation rates and the concentration of albumin and blood, suggest that MRI has the potential for differentiating pleural effusions of different chemical composition.

Albumins↗

Computed tomographic lung density in children.

The effects of patient age, anatomic level, anteroposterior location, and phase of respiration on pulmonary density were analyzed retrospectively in 33 children and prospectively in 13 children. Density standards were positioned on the chest wall for correction of scanner performance changes. The subgroup of 32 children over 7 years of age, ie, with respiratory cooperation, was analyzed separately using moderate inspiration; its mean lung density (MLD) of three levels was -792 HU (95% range, -702-882 HU). Although MLD decreased with increasing age, a significant linear regression was found only in the prospective subgroup. Densities of the apical, subcarinal, and basal levels of the lung were not different. From maximal expiration to maximal inspiration, MLD decreased by 158 HU in the subgroup studied prospectively. Anteroposterior density gradients averaged 56 HU at the subcarinal level and increased with maximal expiration.

Child↗

A ventilator for magnetic resonance imaging.

Breathing motion severely degrades the quality of magnetic resonance images (MRI) of the thorax and upper abdomen and interferes with the acquisition of quantitative data. To minimize these motion effects, we built an MRI compatible ventilator for use in animal studies. Solid state circuitry is used for controlling ventilation parameters. The ventilator can be triggered internally at frequencies of 0.1 to 30 Hz or it can be triggered externally such as by the MRI pulse sequence. When triggered by the scanner, ventilation is synchronized to occur between image data acquisitions. Thus, image data are obtained when there is no breathing motion and at a minimum lung volume when hydrogen density is maximum. Since the ventilator can be adjusted to operate at virtually any frequency from conventional to high frequency, ventilation can be synchronized to all commonly used repetition times (100 ms to 2000 ms or more; 600 to 30 breaths/min). Scan synchronous ventilation eliminates breathing motion artifacts from most imaging sequences (single and multiple spin echo and inversion recovery). Best image quality is obtained when scan synchronous ventilation is combined with cardiac gating. These methods are also useful for quantitative research studies of thoracic and abdominal organs.

Abdomen↗

Regional pulmonary distribution of iodine-125-labeled oleic acid. Its relationship to the pattern of oleic acid edema and pulmonary blood flow.

Oleic acid infusion in dogs produces a patchy, predominantly peripheral lesion on CT scans. This study correlates the pattern of oleic acid injury with the distribution of infused oleic acid and pulmonary blood flow. Radiolabeled oleic acid (I-125, 0.05 ml/kg) and radiolabeled 15-micron microspheres (Co-57) were infused into the right atria of 11 dogs. Oleic acid was given after the microspheres in six dogs and before microspheres in five dogs. Ten minutes after infusion, the lungs were removed. Four transverse slices (0.5 cm thick) of the lower lobes were taken from each dog and cubed. Samples were grouped into three regions of the transverse slice: outer, middle, and inner concentric rings. In both groups, I-125 (oleic acid) activity was greater in the outer than the middle and inner concentric layers (P less than 0.001). When Cobalt-57 microspheres were given before oleic acid, Cobalt-57 activity was marginally lower in the outer layer compared with the middle and inner layers. However, when oleic acid was given first, microsphere activity in the outer layer was significantly lower (P less than 0.001) than the middle layer. Thus, oleic acid was preferentially distributed to the peripheral regions of the lung, similar to the regions of injury on CT. This distribution did not correspond to the pattern of pulmonary blood flow as indicated by the microspheres. Immediately after oleic acid infusion, pulmonary blood flow to the periphery was reduced, reflecting a response to the predominantly peripheral injury by oleic acid.

Animals↗

Distribution of 15- and 137-mu diameter microspheres in the dog lung in the axial plane.

Oleic acid infusion, as a model of fat embolism, produces a predominantly peripheral lesion in the dog lung. The lung injury corresponds to the peripheral distribution of labeled oleic acid. The basis for this distribution of oleic acid is not known. Our hypothesis for this nonuniform distribution is that particle diameter plays a role in the subsequent distribution of infused oleic acid and the resulting lung injury. We injected 15-mu microspheres 85Sr and then 137-mu microspheres (141Ce) into the right atria of seven dogs, which were killed and the lungs removed. Analysis of the distribution of the two different diameter microspheres within axial slices from the left caudal lobe of each dog revealed a peripheral distribution of the larger diameter microspheres not seen with the smaller microspheres.

Animals↗

Magnetic resonance microscopy of the rat thorax and abdomen.

With magnetic resonance (MR) microscopy, high-resolution volumetric imaging (3DFT) of small animals is possible. Although these techniques are suitable for imaging the head and other small stationary objects, breathing and cardiac motion degrade the quality of body images. Scan synchronous ventilation and cardiac gating methods have been developed that permit acquisition of high-resolution images from anywhere in the body of small animals (150 to 400 g). Anesthetized rats were ventilated in synchrony with three-dimensional Fourier spin warp (3DFT) sequence (TR = 400 to 1000 ms, TE = 20 ms). Eight or 16 slices (1.2 or 2.5 mm thick) were acquired simultaneously. Effective pixel size was 200 X 200 mu. Imaging was performed in a 1.5 T, 1-m bore research system using a 28-cm diameter high field gradient coil and a 6-cm diameter radio frequency coil. For thoracic imaging, acquisitions were gated to the QRS of the ECG. Scan synchronous ventilation eliminated breathing motion artifacts and permitted visualization of peripheral vascular structures in the lung and liver. In images that were also cardiac gated, cardiac chambers and major thoracic vessels, including the coronary arteries, were well demonstrated. Thus, thoroughly characterized rodent models can now be studied with MR not only to explore noninvasively the intricacies of mammalian pathomorphology, but also to test the capabilities of MR and aid in interpreting MR data.

Abdomen↗

Noninvasive detection and monitoring of regional myocardial ischemia in situ using depth-resolved 31P NMR spectroscopy.

Phosphorus (31P) NMR spectra showing the relative concentrations of phosphocreatine, ATP, and Pi were recorded noninvasively from localized regions in the left ventricles of dog hearts in situ by using depth-resolved surface-coil spectroscopy at 1.5 T. Proton (1H) NMR surface-coil imaging was used to position 31P NMR coils and to determine the location of depth-resolved volumes immediately prior to 31P examination. Occlusion of the left anterior descending coronary artery produced regional ischemia detected as changes in the ratios of phosphocreatine, ATP, and Pi and by changes in the pH measured from the spectra. Spectral changes were not typically observed in regions adjacent to ischemic myocardium. Reperfusion produced some recovery, and ventricular fibrillation resulted in deterioration in high-energy metabolites. The location and size of ischemic tissue was measured by single-photon-emission computed tomography (SPECT) and gamma-ray counting or by staining excised hearts. The technique should permit the long-term noninvasive monitoring of the metabolic response of the heart to pathologic processes and allow assessment of interventions.

Adenosine Triphosphate↗

Digital radiographic evaluation of the bile ducts.

This study compares digital radiographic images of the bile ducts in dogs with images obtained using routine radiography. The dogs were infused with iodipamide (2 ml/minute for 30 minutes), and the bile ducts were imaged at 60 minutes using plain radiograph and five digital techniques: (1) dual-energy, (2) DSA-hybrid prepixel shift, (3) DSA-hybrid postpixel shift, (4) a dual-energy film system--Digirad, and (5) scan projection radiography using hybrid subtraction. Six radiologists who were not familiar with digital radiography evaluated the six different studies. The images were presented in a randomized order and each image was evaluated on a five-point scale. There was no difference between the plain radiographs and the dual-energy images. Both of these studies were rated significantly better (P less than .001) than the other four digital images. These results suggest that digital radiography during direct cholangiography may be easily accomplished using a 10% to 15% iodine solution.

Animals↗