PubMed Health⌕ Search

Biomedical subjects

L W Ortiz

Publications and source records attributed to L W Ortiz.

5 recordsLinked to original sources

Penetration of respirator filters by an asbestos aerosol.

Five models of respirator filters were challenged with a chrysotile aerosol, and the asbestos fiber penetration of the media was measured in five experimental series simulating different environmental conditions. Penetration of the facial seal was not evaluated. The penetration of each filter was determined from the ratio of the downstream to upstream concentrations of airborne asbestos fibers as measured by the standard National Institute for Occupational Safety and Health (NIOSH) asbestos fiber counting method P&CAM 239. Penetrations measured in this project and presented are indicative of penetrations of filters used a) fresh from the package, b) after exposure to an organic oil mist, c) after storage at high humidity at room and elevated temperatures, and d) after preexposure to water mist. Penetrations varied between less than 0.1% and 2.7% for filters tested fresh from the package and up to 18% after exposure to simulated field/environmental conditions. The data indicate that each of the filter models tested, except for the high efficiency filter, was affected adversely to some degree by one or more of the simulated field/environmental conditions.

Aerosols↗

Calibration standards for counting asbestos.

A laboratory proficiency testing program has been initiated by NIOSH to permit standardization of asbestos counting procedures by various state agencies. This has required preparation of multiple membrane filter samples containing "identical and predictable" concentrations of asbestos fibers, with consistent particulate backgrounds. A technique to filter liquid (toluene) suspensions was developed to provide chrysotile asbestos standards ranging from 200 to 1,500 fibers/mm-2 of filter area, with an aluminum oxide particulate background. Details of the necessary techniques are described. To evaluate variations inherent in preparing these "identical" samples and to estimate variations between different counters, extensive replicate fiber counting was performed. Count data from several counters at a single facility show that this liquid suspension filtration technique provides reproducible asbestos standards as measured by optical microscopy with a coefficient of variation of plus or minus 20% with the maximum individual variations of plus or minus 50%.

Air Pollution↗