Boron neutron capture therapy for glioblastoma multiforme: interim results from the phase I/II dose-escalation studies

OBJECTIVE: The primary objective of these Phase I/II dose-escalation studies is to evaluate the safety of boronophenylalanine (BPA)-fructose-mediated boron neutron capture therapy (BNCT) for patients with glioblastoma multiforme (GBM). A secondary purpose is to assess the palliation of GBM by BNCT, if possible. METHODS: Thirty-eight patients with GBM have been treated. Subtotal or gross total resection of GBM was performed for 38 patients (median age, 56 yr) before BNCT. BPA-fructose (250 or 290 mg BPA/kg body weight) was infused intravenously, in 2 hours, approximately 3 to 5 weeks after surgery. Neutron irradiation was begun between 34 and 82 minutes after the end of the BPA infusion and lasted 38 to 65 minutes. RESULTS: Toxicity related to BPA-fructose was not observed. The maximal radiation dose to normal brain varied from 8.9 to 14.8 Gy-Eq. The volume-weighted average radiation dose to normal brain tissues ranged from 1.9 to 6.0 Gy-Eq. No BNCT-related Grade 3 or 4 toxicity was observed, although milder toxicities were seen. Twenty-five of 37 assessable patients are dead, all as a result of progressive GBM. No radiation-induced damage to normal brain tissue was observed in postmortem examinations of seven brains. The minimal tumor volume doses ranged from 18 to 55 Gy-Eq. The median time to tumor progression and the median survival time from diagnosis (from Kaplan-Meier curves) were 31.6 weeks and 13.0 months, respectively. CONCLUSION: The BNCT procedure used has been safe for all patients treated to date. Our limited clinical evaluation suggests that the palliation offered by a single session of BNCT is comparable to that provided by fractionated photon therapy. Additional studies with further escalation of radiation doses are in progress.

Journal Article

Boron neutron-capture therapy (BNCT) for glioblastoma multiforme (GBM) using the epithermal neutron beam at the Brookhaven National Laboratory.

OBJECTIVE: Boron neutron-capture therapy (BNCT) is a binary form of radiation therapy based on the nuclear reactions that occur when boron (10B) is exposed to thermal neutrons. Preclinical studies have demonstrated the therapeutic efficacy of p-boronophenylalanine (BPA)-based BNCT. The objectives of the Phase I/II trial were to study the feasibility and safety of single-fraction BNCT in patients with GBM. MATERIALS AND METHODS: The trial design required (a) a BPA biodistribution study performed at the time of craniotomy; and (b) BNCT within approximately 4 weeks of the biodistribution study. From September 1994 to July 1995, 10 patients were treated. For biodistribution, patients received a 2-hour intravenous (i.v.) infusion of BPA-fructose complex (BPA-F). Blood samples, taken during and after infusion, and multiple tissue samples collected during surgical debulking were analyzed for 10B concentration. For BNCT, all patients received a dose of 250 mg BPA/kg administered by a 2-hour i.v. infusion of BPA-F, followed by neutron beam irradiation at the Brookhaven Medical Research Reactor (BMRR). The average blood 10B concentrations measured before and during treatment were used to calculate the time of reactor irradiation that would deliver the prescribed dose. RESULTS: 10B concentrations in specimens of scalp and tumor were higher than in blood by factors of approximately 1.5 and approximately 3.5, respectively. The 10B concentration in the normal brain was < or = that in the blood; however, for purposes of estimating radiation doses to normal brain endothelium, it was always assumed to be equal to blood. BNCT doses are expressed as gray-equivalent (Gy-Eq), which is the sum of the various physical dose components multiplied to appropriate biologic effectiveness factors. The dose to a 1-cm3 volume where the thermal flux reached a maximum was 10.6 +/- 0.3 Gy-Eq in 9 patients and 13.8 Gy-Eq in 1 patient. The minimum dose in tumor ranged from 20 to 32.3 Gy-Eq. The minimum dose in the target volume (tumor plus 2 cm margin) ranged from 7.8 to 16.2 Gy-Eq. Dose to scalp ranged from 10 to 16 Gy-Eq. All patients experienced in-field alopecia. No CNS toxicity attributed to BNCT was observed. The median time to local disease progression following BNCT was 6 months (range 2.7 to 9.0). The median time to local disease progression was longer in patients who received a higher tumor dose. The median survival time from diagnosis was 13.5 months. CONCLUSION: It is feasible to safely deliver a single fraction of BPA-based BNCT. At the dose prescribed, the patients did not experience any morbidity. To further evaluate the therapeutic efficacy of BNCT, a dose-escalation study delivering a minimum target volume dose of 17 Gy-Eq is in progress.

Aged

Boron neutron capture therapy: re-irradiation response of the rat spinal cord.

PURPOSE: To evaluate the retreatment response of the CNS to BNC irradiation using a rat spinal cord model. MATERIALS AND METHODS: Fischer 344 rats were irradiated with single doses of 6 MeV X-rays which were 22, 40 or 80% of a total effect (TE). An additional group of rats was irradiated with a single exposure of thermal neutrons in the presence of the neutron capture agent boronophenylalanine (BPA) to a dose that represented 82% of the TE. After an interval of 26 weeks, animals were re-irradiated using various single doses of thermal neutrons in combination with BPA. RESULTS: The re-irradiation ED50 doses represented 77, 80 or 50% of the TE after an initial X-ray dose of 22, 40 or 80% of the TE, respectively. The re-irradiation ED50 dose was 55% of the TE after an initial BNC irradiation dose representing 82% of the TE. CONCLUSION: The level of the initial radiation damage had a direct bearing on the re-irradiation response. Recovery following initial treatment with BNC irradiation was similar to that after initial irradiation with X-rays.

Animals

The effect of high-linear energy transfer ions on the electron paramagnetic resonance signal induced in alanine.

Microcrystalline samples of L-alanine irradiated with energetic high-LET cobalt and iron ions had different EPR spectra compared to alanine samples irradiated with low-LET photons. The differences in the shapes of the EPR spectra and their dependence on the microwave power are related to the differences in the microwave power saturation of the radicals induced by the various types of ionizing radiation. The changes in the shape of the EPR spectra, which were caused by increasing microwave power, were more pronounced in samples irradiated with low-LET radiation than with high-LET particles. This effect showed a long-term stability and can be used to monitor radiation quality.

Alanine

Impaired permeability in radiation-induced lung injury detected by technetium-99m-DTPA lung clearance.

UNLABELLED: This study evaluates the use of the 99mTc-DTPA aerosol lung clearance method to investigate radiation-induced lung changes in eight patients undergoing radiotherapy for lung or breast carcinoma. The sensitivity of the method was compared with chest radiography for detecting radiation-induced changes in the lung, regional alterations within (irradiated region) and outside (shielded region) the treatment ports, effect of irradiated lung volume, and dependence on time after radiotherapy. METHODS: Serial DTPA lung clearance studies were performed before the first radiation treatment (baseline), then weekly during a 5- to 7-wk course, and up to 12 times post-therapy over periods of 56-574 days. The total activity deposited in the lungs for each study was approximately 150 microCi (approximately 5.6 MBq). DTPA clearance, expressed in terms of the biological half-time, t 1/2, was computed from the slopes of the least-squares fit regression lines of the time-activity curves for the first 10 min for irradiated and shielded lung regions. RESULTS: Major findings include: (a) significant and early DTPA t 1/2 changes were observed in all patients during and after radiotherapy; (b) changes in DTPA t 1/2 values were observed in both irradiated and shielded lung regions in all patients suggesting a radiation-induced systemic reaction; (c) changes in DTPA t 1/2 values were correlated (p < 0.05) with the irradiated lung volumes; (d) significantly reduced DTPA t 1/2 values were observed in three patients who subsequently presented with clinical symptoms and/or radiographic changes consistent with radiation pneumonitis (t1/2 felt to 19% +/- 6% of baseline values, compared with 64% +/- 17% in the remaining patients [p < 0.01]); (e) the onset of decreased DTPA t 1/2 values in these three patients occurred 35-84 days before clinical symptoms and/or radiographic changes; and (f) DTPA t 1/2 tended to approach baseline values with time after radiotherapy, suggesting a long-term recovery in lung injury. CONCLUSION: These observations show significant and early alterations in DTPA lung clearance during and after radiotherapy that may provide a sensitive assay to monitor changes in radiation-induced lung injury and may facilitate early therapeutic intervention.

Aerosols

Current misinterpretations of the linear no-threshold hypothesis.

Contrary to the "linear no-threshold hypothesis," which implies that "any amount, however small" of radiation energy is a serious cancer threat, it is shown here that only relatively quite large amounts of such energy can pose such a threat to a person or population. Key to doing this is to make a sharp distinction between the actual amount of the radiation agent imparted energy, epsilon, which must be expressed in units of joules, and the average concentration or density of energy, epsilon/m (i.e., absorbed dose), which is expressed in units of Gy. With any cellular system, e.g., in tissue culture, one can easily adjust the numbers of cells used at each dose point so that a clearly significant number of radiation-induced quantal responses (e.g., mutations, chromosome aberrations, malignant transformations, cell death), in the absorbed dose range of about 0.7 to 3 or more Gy, can be observed. However, if the number of cells is held constant as the absorbed dose is progressively reduced, a point is reached at which no significant excess is observable. This situation is frequently "remedied" by including more cells at that point, which, of course, can increase the number of malignant transformations sufficiently to render the excess statistically valid. However, because both axes are expressed in relative terms, the data point, despite having gained statistical significance, remains at the same location on the graph. This gives the false impression that no more of the agent energy was added or needed to achieve significance. However, if both coordinates are put in absolute terms, i.e., the actual number of quantal responses vs. imparted energy, and the same exercise of "improving the statistics" at low exposures is attempted, it then becomes evident that any point thus rendered significant must be relocated at a substantially higher energy point on the graph. This demonstrates unequivocally the fallacy in the proof of the "linear hypothesis" which is based on agent concentration response curves and not agent amount. It shows that the smaller the agent concentration (absorbed dose; epsilon/m), the larger the amount of radiation energy that must be added to the system in order to demonstrate a radiation-induced response. This suggests a minimum average energy requirement for production of a radiation-attributable cancer. It Ls concluded that the "linear hypothesis" should be abandoned as the cornerstone of radiation protection and practice.

Dose-Response Relationship, Radiation

A novel comprehensive quality control instrument for medical accelerators.

A comprehensive quality control instrument for calibration of medical accelerators that use photon, electron, or proton beams in teleradiotherapy is described. It employs a fluorescence screen, mounted on a central stage with four degrees of freedom, monitored by a CCD camera. A single set-up of the instrument enables one to perform mechanical, light laser, and radiation tests, at arbitrary angles of the accelerator gantry. The new device provides for quantitative evaluation of the tests performed and provides for documentation of the test results in real time. The device provides significant time savings with concurrent improvement in accuracy for tests performed during installation and acceptance processes, and the implementation of quality control procedures for medical accelerators.

Electrons

The effects of boron on the electron paramagnetic resonance spectra of alanine irradiated with thermal neutrons.

The effects of boric acid admixture on the intensity and line structure of EPR spectra of free radicals produced in alanine by thermal neutrons are presented. The EPR signal enhancement, up to a factor of 40 depending on the boron concentration, is related to additional energy deposition in alanine crystals by the disintegration products resulting from the capture of a thermal neutron by boron, 10B(n,alpha)7Li. The changes in the shape of the EPR spectra observed by changing the microwave power are due to the differences in the microwave power saturation of the free radicals produced by a low-LET radiation and those produced by the high-LET components of the radiation after the neutron capture reaction.

Alanine

The equal effectiveness ratio: a quantitative approach to the evaluation of compounds for boron neutron capture therapy.

The resurgence of interest in boron neutron capture therapy (BNCT) as a potential treatment for glioblastomas and melanomas has resulted in a quest to identify and synthesize candidate compounds which can physiologically target the 10B atoms to tumor cells. Numerous boron-carrying compounds are now available and awaiting evaluation. Because the products of the boron neutron capture (BNC) reaction generally contribute greater than 50% of the dose in BNCT, the evaluation of the efficacy of boron compounds would be more precise if it were possible to remove, quantitatively, the dose contributed by the external reactor radiations. The purpose of this study is to report a method which does just that, i.e., leaves for precise evaluation the biological effect that is ascribable to the BNC products only. The evaluation involves a series of separately quantifiable factors, the product of which provides an overall "figure of merit" for the compound.

Animals

The effects of dose and radiation quality on the shape and power saturation of the EPR signal in alanine.

Variations in the shape and the power saturation of EPR spectra of L-alanine irradiated with photons, electrons, neutrons and protons are reported. It is shown that the ratio of the intensities of the satellite lines attributable to "spin flips" and the central line depend on the EPR microwave power, and it is proposed as a quantitative measure of the signal saturation effect. Dependence of this ratio on the microwave power is affected by the radiation quality and for doses in excess of 10 kGy by the absorbed dose. At high doses of low-LET radiation these changes are attributed to a high local density of free radicals, while for low doses of high-LET radiation these are due to changes induced in the crystal lattice. Consequently, the conventional peak-to-peak amplitude measurement of the EPR signal intensity is inaccurate when used for high doses and for comparison between radiations with different beam quality. The possibility to determine radiation quality from an EPR measurement is discussed.

Alanine

In vivo animal models of body composition in aging.

We developed several techniques that provide data on body elemental composition from in vivo measurements in rats. These methods include total body potassium by whole-body counting of endogenous 40K; total body calcium (TBCa), sodium and chloride by in vivo neutron activation analysis and total body phosphorus (TBP) and nitrogen (TBN) by photon activation analysis. These elements provide information on total body fat, total body protein and skeletal mass. Measurements were made in 6-, 12- and 24-month-old rats. TBN increased slightly between 6 and 12 months but was significantly lower by 24 months, indicating a substantial loss in total body protein. Working at the National Synchrotron Light Source, we studied rat femurs by computed microtomography (CMT), and the elemental profile of the femur cortex by synchrotron-radiation induced X-ray emission (SRIXE). Although there were no significant changes in TBCa and TBP, indices of skeletal mass, CMT revealed a marked increase in the size and number of cavities in the endosteal region of the femur cortex with increasing age. The SRIXE analysis of this cortical bone revealed a parallel decrease in the endosteal Ca/P ratio. Thus, there are major alterations in bone morphology and regional elemental composition despite only modest changes in total skeletal mass.

Aging

Noninvasive in-vivo measurement of hepatic and cardiac iron.

This study describes a new noninvasive in-vivo method of appraising human iron stores by nuclear resonance scattering (NRS). Manganese-56 is used as a source of 847 keV gamma rays which scatter resonantly from the iron in the liver and heart of patients with Cooley's anemia (thalassemia major). These patients have heavy iron overload that may lead to cardiac and other organ failure. The NRS iron quantitation of the liver compared favorably, in a linear fashion, with the iron in the liver biopsies. Above initial value, the hepatic iron correlates with the cardiac NRS signal. There is no correlation, however, between liver enzymes and degree of iron load. NRS appears to be a reliable method for measuring cardiac and hepatic iron. It may be repeated as needed to determine the effectiveness, selectivity and compliance to therapy and prognosis.

Adolescent

Depth dose and profile analysis using Library Least-Squares method.

The Library Least-Squares method has been applied to detect changes in the depth dose and in the profiles of 6 and 20 MeV electron beams, and in 6 MeV photon beams from medical linear accelerators. The changes in the beam energy of 0.78% and 0.32% at low and high electron energies, respectively, induced by the insertion of 0.1 mm A1 absorber were clearly visible in the residual distributions. The changes in the photon beam were introduced by rotation of the gantry or the collimator. The applicability of the method to quantitatively monitor any changes in the treatment beam characteristics is presented.

Calibration

Sequential measurements of bone lead content by L X-ray fluorescence in CaNa2EDTA-treated lead-toxic children.

With the development of L X-ray fluorescence (LXRF) to measure cortical bone lead directly, safely, rapidly, and noninvasively, the present study was undertaken to a) evaluate LXRF as a possible replacement for the CaNa2EDTA test; b) quantify lead in tibial cortical bones of mildly to moderately lead-toxic children before treatment; and c) quantify lead in tibial cortical bones of lead-toxic children sequentially following one to two courses of chelation therapy. The clinical research design was based upon a longitudinal assessment of 59 untreated lead-toxic children. At enrollment, if the blood lead (PbB) was 25 to 55 micrograms/dL and the erythrocyte protoporphyrin (EP) concentration was greater than or equal to 35 micrograms/dL, LXRF measurement of tibial bone lead was carried out. One day later, each child underwent a CaNa2EDTA provocative test. If this test was positive, lead-toxic children were admitted to the hospital for 5 days of CaNa2EDTA therapy. These tests were repeated 6 weeks and 6 months after enrollment. Abatement of lead paint hazards was achieved in most apartments by the time of initial hospital discharge. The LXRF instrument consists of a low energy X-ray generator with a silver anode, a lithium-doped silicon detector, a polarizer of incident photons, and a multichannel X-ray analyzer. Partially polarized photons are directed at the subcutaneous, medial mid-tibial cortical bone. The LXRF spectrum, measured 90 degrees from the incident beam, reveals a peak in the 10.5 KeV region, which represents the lead L alpha line.(ABSTRACT TRUNCATED AT 250 WORDS)

Bone and Bones

Sequential measurements of bone lead content by L X-ray fluorescence in CaNa2EDTA-treated lead-toxic children.

With the development of L X-ray fluorescence (LXRF) to measure cortical bone lead directly, safely, rapidly, and noninvasively, the present study was undertaken to a) evaluate LXRF as a possible replacement for the CaNa2EDTA test; b) quantify lead in tibial cortical bones of mildly to moderately lead-toxic children before treatment; and c) quantify lead in tibial cortical bones of lead-toxic children sequentially following one to two courses of chelation therapy. The clinical research design was based upon a longitudinal assessment of 59 untreated lead-toxic children. At enrollment, if the blood lead (PbB) was 25 to 55 micrograms/dL and the erythrocyte protoporphyrin (EP) concentration was greater than or equal to 35 micrograms/dL, LXRF measurement of tibial bone lead was carried out. One day later, each child underwent a CaNa2EDTA provocative test. If this test was positive, lead-toxic children were admitted to the hospital for 5 days of CaNa2EDTA therapy. These tests were repeated 6 weeks and 6 months after enrollment. Abatement of lead paint hazards was achieved in most apartments by the time of initial hospital discharge. The LXRF instrument consists of a low energy X-ray generator with a silver anode, a lithium-doped silicon detector, a polarizer of incident photons, and a multichannel X-ray analyzer. Partially polarized photons are directed at the subcutaneous, medial mid-tibial cortical bone. The LXRF spectrum, measured 90 degrees from the incident beam, reveals a peak in the 10.5 KeV region, which represents the lead L alpha line.(ABSTRACT TRUNCATED AT 250 WORDS)

Bone and Bones

Installation and testing of an optimized epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR).

NCT is a binary system, in which 10B is physiologically targeted to tumor and then allowed to interact with thermal neutrons generated in the treatment volume by an externally applied neutron beam. Consequently, an unusually large number of parameters are obtained, which bear on the resultant Therapeutic Gain (TG). However, a perusal of these data, as illustrated in Figure 7, indicates that the TG would increase significantly beyond values projected in this paper if the absolute amount of 10B could be increased above 30 ppm. For example, increasing 10B concentration in tumor to 45 ppm would increase TG by approximately 33% (with a T/N of 5). A similar increase in TG would follow an increase in T/N from 5 to 10. Those associated with the development of boron compounds for NCT feel that such developments are within reach.

Boron Compounds

Analysis of 5-iodo-2'-deoxyuridine incorporation in murine melanoma for photon activation therapy.

Quantitative evaluation of the dose enhancement obtained with analog nucleoside agents such as iododeoxyuridine (IdUrd) requires knowledge of the degree to which the thymidine (Thd) in DNA is replaced by IdUrd. In the present investigation, mice were infused with IdUrd using an intravenous infusion apparatus capable of delivering continuous multi-day infusions without restraining the mice. The absolute incorporation of IdUrd in DNA was measured by 125IdUrd label, both in whole tissue and extracted DNA, showing a good correlation between levels observed in DNA and whole tissue. Replacement in a Harding-Passey murine melanoma tumor carried in BALB/c mice approached 10%. In addition, a Neutron Activation Analysis (NAA) technique was developed which showed in vitro, a sensitivity sufficient to evaluate the % replacement of Thd by IdUrd in small biological samples with a sensitivity greater than 0.1 ppm, at 1% replacement in mg samples. This method can provide information on iodine substitution in DNA in humans where the use of a radioactive DNA-seeking substance would be undesirable. Analyses of IdUrd incorporation in cultured cells by NAA and 125I counting showed good agreement.

Animals