"Nonisolated-sensor" solid polystyrene absorbed dose measurements.

A "nonisolated-sensor" solid polystyrene calorimeter was constructed to test the role of thermal diffusion in limiting the length of irradiation time during which temperature measurements with nonisolated sensors could be made sufficiently free of drift for determining dose with radiation fields such as gamma rays, x rays, and high-energy electrons. From measured ratios of dose at 5.0 and 0.5 cm in polystyrene and comparisons to dose measurements with a polystyrene parallel-plate (pancake) ion chamber, it was shown that thermal diffusion is sufficiently small in polystyrene to permit accurate measurements for irradiation periods of less than 20 min. Comparison of the absorbed dose measurements and depth dose ratios with pancake ion chambers and calorimeter showed, that within the precision and accuracy of the two measuring systems, there is close agreement. The nonisolated-sensor solid polystyrene calorimeter has the interesting features of (i) simplicity of construction, (ii) simplicity of operation without vacuum or feedback for temperature control, (iii) capability of simultaneous measurements at several depths and off-axis positions, (iv) the very small thermal defect correction with polystyrene, and (v) operation with the calorimeter in any orientation.

Calorimetry↗

Phosphorus activation neutron dosimetry and its application to an 18-MV radiotherapy accelerator.

Neutron fluxes and dose rates in and near the 18-MV x-ray beam of a Therac-20 accelerator were determined with measured activities from the nuclear reactions 31P(n, rho)31Si (fast neutrons) and 31P(n, gamma)32P (thermal neutrons), published cross sections, and neutron energy spectra from Monte Carlo calculations. Measurements were made in the patient plane in air and at a 10-cm depth in a tissue-similar phantom, and in a plane containing the x-ray target. Orthophosphoric acid solution was identified as a suitable and convenient phosphorus dosimeter material. In the 31P activation method, fluxes and dose rates are determined as the product of measured saturation activity per 31P atom and a conversion factor, which depends on the shape of the assumed neutron spectrum. For fast neutrons, which deliver most of the dose, the accuracy error in the saturation activity determinations was shown to be approximately less than 25%. An inconsistency resulting from neglect of the accelerator's adjustable collimator in the Monte Carlo calculations was demonstrated between the measured saturation activities and the theoretical neutron spectra. The maximum neutron dose equivalent rate observed was 5.9 mSv/Gy of x-ray absorbed dose at the accelerator calibration point. Surface dose equivalent rates of the present study are less than those of fluxmeter and remmeter studies at sites outside Therac-20 treatment fields by as much as factors of 2.4 and 2.8, respectively. The phantom study showed that at 18 MV internally produced neutrons have a negligible effect on the neutron field within the patient.

Neutrons↗

Improved "nonisolated-sensor" solid polystyrene calorimeter.

A "nonisolated-sensor" solid polystyrene calorimeter is described which permits absorbed dose measurements with precision of less than 0.3% (standard error of the mean). The accuracy for obtaining absolute absorbed dose was estimated by comparisons with cavity ionization measurements. The calculation of absorbed dose with ionization chambers was carried out based upon the TG-21 AAPM dosimetry protocol. Measurements in a 60Co gamma-ray field with three different polystyrene parallel-plate ion chambers in a polystyrene phantom did not differ by more than 1.5% from that obtained with the polystyrene calorimeter. Measurements taken over a period of 247 days are compared with the expected values on the basis of the decay 60Co. The calorimeter system, with its capability of acquiring, printing, storing, plotting, and analyzing the data by computer, is described.

Calorimetry↗

Design of apparatus for precise x-ray dose chamber calibrations.

An apparatus for precision calibration of ion chambers in the x-ray region from 16 to 320 kV is described. The development of a fast-acting shutter with "opening" and "closing" times of less than 3-ms eliminates the requirement for operating time corrections. Controls from outside the radiation room permit changing x-ray filters and alternately positioning both test and standard ion chambers in the x-ray beam. Thus, the remote controls eliminate the need to enter the x-ray room in the course of a series of calibrations. The potential advantages resulting from the capabilities of this apparatus are described in this Technical Report.

Calibration↗