PubMed Health⌕ Search

Biomedical subjects

L de Carlan

Publications and source records attributed to L de Carlan.

10 recordsLinked to original sources

Application of voxel phantoms in whole-body counting for the validation of calibration phantoms and the assessment of uncertainties.

This article is dedicated to the application of voxel phantoms in whole-body counting calibration. The first study was performed to validate this approach using IGOR, a physical phantom dedicated to fission and activation product (FAP) measurement, and a graphical user interface, developed at the IRSN internal dose assessment laboratory, called OEDIPE (French acronym for the tool for personalised internal dose assessment) associated with the Monte Carlo code MCNP. The method was validated by comparing the results of real measurements and simulations using voxel phantoms obtained from CT scan images of IGOR. To take this application further, two studies were carried out and are presented in this article. First, a comparison was made between the IGOR voxel based phantom (IGOVOX) and a voxel human body (Zubal Phantom) to confirm whether IGOR could be considered as a realistic representation of a human. Second, the errors made when considering sources homogeneously distributed in the body were assessed against real contamination by taking into account the biokinetic behaviour of the radioactive material for two modes of exposure: the ingestion of 137Cs in soluble form and the inhalation of insoluble 60Co several days after acute incorporation.

Algorithms↗

New method of voxel phantom creation: application for whole-body counting calibration and perspectives in individual internal dose assessment.

The purpose of this work is to present an innovative approach for the creation and application of voxel phantoms associated with the Monte Carlo calculation (MCNP) for the calibration of whole-body counting systems dedicated to the measurement of fission and activation products. The new method is based on a graphical user interface called 'OEDIPE' that allows to simulate a whole measurement process using all measurement parameters, the final goal being to approach a numerical calibration of the facilities. The creation of voxel phantoms and validation of the method are presented in this paper using the IGOR phantom. Finally, the efficiency of the method is discussed, in particular, with the perspective of validating IGOR as a suitable human-equivalent phantom and for the assessment of uncertainties in dose estimation due to the inhomogeneous distribution of activity in the body, correlated to the bio-kinetic behaviour of the radionuclides.

Body Burden↗

Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources.

This paper aims at comparing dosimetric assessments performed with three Monte Carlo codes: EGS4, MCNP4c2 and MCNPX2.5e, using a realistic voxel phantom, namely the Zubal phantom, in two configurations of exposure. The first one deals with an external irradiation corresponding to the example of a radiological accident. The results are obtained using the EGS4 and the MCNP4c2 codes and expressed in terms of the mean absorbed dose (in Gy per source particle) for brain, lungs, liver and spleen. The second one deals with an internal exposure corresponding to the treatment of a medullary thyroid cancer by 131I-labelled radiopharmaceutical. The results are obtained by EGS4 and MCNPX2.5e and compared in terms of S-values (expressed in mGy per kBq and per hour) for liver, kidney, whole body and thyroid. The results of these two studies are presented and differences between the codes are analysed and discussed.

Computer Simulation↗

Current developments at IRSN on computational tools dedicated to assessing doses for both internal and external exposure.

The paper presents the OEDIPE (French acronym that stands for tool for personalised internal dose assessment) and SESAME (for simulation of external source accident with medical images) computational tools, dedicated to internal and external dose assessment, respectively, and currently being developed at the Institute for Radiological Protection and Nuclear Safety. The originality of OEDIPE and SESAME, by using voxel phantoms in association with Monte Carlo codes, lies in their ability to construct personalised voxel phantoms from medical images and automatically generate the Monte Carlo input file and visualise the expected results. OEDIPE simulates in vivo measurements to improve their calibration, and calculates the dose distribution taking both internal contamination and internal radiotherapy cases into account. SESAME enables radiological overexposure doses to be reconstructed, as also victim, source and accident environment modelling. The paper presents the principles on which these tools function and an overview of specificities and results linked to their fields of application.

Academies and Institutes↗

A computational tool based on voxel geometry for dose reconstruction of a radiological accident due to external exposure.

In the case of overexposure to ionising radiation, estimation of the absorbed dose in the organism is an important indicator for evaluating the biological consequences of this exposure. The physical dosimetry approach is based either on real reconstruction of the accident, using physical phantoms, or on calculation techniques. Tools using Monte Carlo simulations associated with geometric models are very powerful since they offer the possibility to simulate faithfully the victim and the environment for dose calculations in various accidental situations. Their work presents a new computational tool, called SESAME, dedicated to dose reconstruction of radiological accidents based on anthropomorphic voxel phantoms built from real medical images of the victim in association with the MCNP Monte Carlo code. The utility was, as a first step, validated for neutrons by experimental means using a physical tissue-equivalent phantom.

Algorithms↗

Application of new imaging and calculation techniques to activity and dose assessment in the case of a 106Ru contaminated wound.

The aim of this paper is to describe the dosimetric evaluation of a point contamination that occurred in a laboratory during the examination of an irradiated sample. The incident led to point contamination of the operator's finger due to the presence of mainly 106Ru, with its progeny, 106Rh. The paper reports on the activity and dose assessment, performed using several methods. The measured activity was obtained using a conventional device based on a germanium detector and confirmed using software developed at IRSN, based on reconstruction of voxel phantom associated with the Monte Carlo N-Particle code (MCNP) for in vivo measurement. Two dose assessment calculations were performed using both analytical and Monte Carlo methods, applying the same approach as for activity assessment based on the personal computational phantom of the finger. The results are compared, followed by a discussion on the suitability of the tools described in this study.

Computer Simulation↗

Application of Monte Carlo calculations to calibration of anthropomorphic phantoms used for activity assessment of actinides in lungs.

This paper reports on a new utility for development of computational phantoms for Monte Carlo calculations and data analysis for in vivo measurements of radionuclides deposited in tissues. The individual parameters of each worker can be acquired for an exact geometric representation of his or her anatomy, which is particularly important for low-energy gamma ray emitting sources such as thorium, uranium, plutonium and other actinides. The software discussed here enables automatic creation of an MCNP input data file based on computed tomography (CT) scanning data. The utility was first tested for low- and medium-energy actinide emitters on Livermore phantoms, the mannequins generally used for lung counting, in order to compare the results of simulation and measurement. From these results, the utility's ability to study uncertainties in in vivo calibration were investigated. Calculations and comparison with the experimental data are presented and discussed in this paper.

Actinoid Series Elements↗

Developments in internal monitoring techniques.

In an effort to increase accuracy and speed, improve detection limits and reduce uncertainties in internal dosimetry, laboratories have developed improved or new internal monitoring techniques in both in vivo measurements and bioassay analyses. Most of these techniques have not yet entered routine monitoring programmes. This paper intends to summarise these new techniques, show their potential improvements compared to the currently employed monitoring routines and discuss the main aspects of the EC-funded IDEA project, which aims at a comprehensive assessment of these techniques and the enhancements necessary to bring them to broader acceptance in the routine monitoring community.

European Union↗

The reduction of limits of detection in in vivo counting of low-energy photon emitters by optimising the shape and size of detectors.

This paper compares three ways to reduce the detection limits of in vivo measurements by using passive techniques: the use of shielded rooms, the use of underground laboratories and the adjustment of the detector's dimensions to the examined energy. This study indicates that the efficiency of the detector is not the critical parameter for achieving sensitive measurements in the low-energy range and is secondary to optimisation of the background level. However, reduction of the background has a limited impact on the sensitivity of counting due to 40K in the body. This study also shows that the advantage of using deep underground laboratories could be replaced by detectors with properly designed shape and size and used at ground level in normally shielded rooms to reach the necessary limits of detection for in vivo assessment of low-energy photon emitters.

Artifacts↗

A new graphical user interface for fast construction of computation phantoms and MCNP calculations: application to calibration of in vivo measurement systems.

The paper reports on a new utility for development of computational phantoms for Monte Carlo calculations and data analysis for in vivo measurements of radionuclides deposited in tissues. The individual properties of each worker can be acquired for a rather precise geometric representation of his (her) anatomy, which is particularly important for low energy gamma ray emitting sources such as thorium, uranium, plutonium and other actinides. The software discussed here enables automatic creation of an MCNP input data file based on scanning data. The utility includes segmentation of images obtained with either computed tomography or magnetic resonance imaging by distinguishing tissues according to their signal (brightness) and specification of the source and detector. In addition, a coupling of individual voxels within the tissue is used to reduce the memory demand and to increase the calculational speed. The utility was tested for low energy emitters in plastic and biological tissues as well as for computed tomography and magnetic resonance imaging scanning information.

Calibration↗