PubMed Health⌕ Search

Biomedical subjects

L. Joshua Leon

Publications and source records attributed to L. Joshua Leon.

2 recordsLinked to original sources

Development of a computer algorithm for the detection of phase singularities and initial application to analyze simulations of atrial fibrillation.

Atrial fibrillation (AF) is a common cardiac arrhythmia, but its mechanisms are incompletely understood. The identification of phase singularities (PSs) has been used to define spiral waves involved in maintaining the arrhythmia, as well as daughter wavelets. In the past, PSs have often been identified manually. Automated PS detection algorithms have been described previously, but when we attempted to apply a previously developed algorithm we experienced problems with false positives that made the results difficult to use directly. We therefore developed a tool for PS identification that uses multiple strategies incorporating both image analysis and mathematical convolution for automated detection with optimized sensitivity and specificity, followed by manual verification. The tool was then applied to analyze PS behavior in simulations of AF maintained in the presence of spatially distributed acetylcholine effects in cell grids of varying size. These analyses indicated that in almost all cases, a single PS lasted throughout the simulation, corresponding to the central-core tip of a single spiral wave that maintained AF. The sustained PS always localized to an area of low acetylcholine concentration. When the grid became very small and no area of low acetylcholine concentration was surrounded by zones of higher concentration, AF could not be sustained. The behavior of PSs and the mechanisms of AF were qualitatively constant over an 11.1-fold range of atrial grid size, suggesting that the classical emphasis on tissue size as a primary determinant of fibrillatory behavior may be overstated. (c) 2002 American Institute of Physics.

Journal Article↗

A method for visualization of ventricular fibrillation: Design of a cooled fiberoptically coupled image intensified CCD data acquisition system incorporating wavelet shrinkage based adaptive filtering.

The measurement of cardiac transmembrane potential changes with voltage sensitive dyes is in increasing use. Detection of these very small fluorescent alterations using large multiplexed arrays, such as charge coupled device (CCD) cameras at high sampling rates, has proven challenging and usually requires significant averaging to improve the signal-to-noise ratio. To minimize the damage of living tissue stained with voltage sensitive dyes, excitation photon exposure must be limited, with the inevitable consequence of diminishing the fluorescence that is generated. State-of-the-art high frame rate CCD cameras have read noise levels in the 5-10 e(-) rms range, which is at least two orders of magnitude above that required to detect voltage sensitive dye alterations at individual pixels corresponding to 1 mm(2) heart regions illuminated with levels of 100 mW/cm(2) at frame rates approaching 1000 frames/sec. Image intensification is thus required prior to photon quantification. We report here the development of such a data acquisition system using commercially available hardware. Additionally, in the past ten years, a mathematical theory of multiresolution has been developed, and new building blocks called wavelets, allow a signal to be observed at different resolutions. Wavelet analysis also makes possible a new method of extricating signals from noise. We have incorporated spatially adaptive filters based on wavelet denoising of individual pixels to significantly reduce the multiple noise sources present in the acquired data. (c) 1998 American Institute of Physics.

Journal Article↗