PubMed Health⌕ Search

Biomedical subjects

Lai-Kwan Chau

Publications and source records attributed to Lai-Kwan Chau.

3 recordsLinked to original sources

Sensing capability of the localized surface plasmon resonance of gold nanorods.

We demonstrate the feasibility of using the longitudinal component of gold nanorod's surface plasmon resonance in biomolecular sensing. The sensitive dependence of the absorption maximum on the dielectric constant of the particle interfacial region makes gold nanorods a promise for constructing a biomolecular sensing scheme. The sensor containing gold nanorods, with a mean aspect ratio of 5.2, exhibits a sensitivity of ca. 366 nm/RIU (refractive index unit), which increases accordingly with the increase of the particle mean aspect ratios. Such a biosensor was further modified to demonstrate its effectiveness in quantitative detection for selective binding events, such as biotin/streptavidin pairs, through a process in which biotin molecules were chemically attached to the gold nanorods' surface prior to detection measurements. Results showed that the spectral lambda(max) shifts linearly to the concentrations of the streptavidin. The results from both experiment and model calculations strongly indicate the efficacy of the longitudinal surface plasmon absorption band in biosensing.

Biopolymers↗

Colloidal gold-modified optical fiber for chemical and biochemical sensing.

A novel class of fiber-optic evanescent-wave sensor was constructed on the basis of modification of the unclad portion of an optical fiber with self-assembled gold colloids. The optical properties and, hence, the attenuated total reflection spectrum of self-assembled gold colloids on the optical fiber changes with different refractive index of the environment near the colloidal gold surface. With sucrose solutions of increasing refractive index, the sensor response decreases linearly. The colloidal gold surface was also functionalized with glycine, succinic acid, or biotin to enhance the selectivity of the sensor. Results show that the sensor response decreases linearly with increasing concentration of each analyte. When the colloidal gold surface was functionalized with biotin, the detection limit of the sensor for streptavidin was 9.8 x 10(-11) M. Using this approach, we demonstrate proof-of-concept of a class of refractive index sensor that is sensitive to the refractive index of the environment near the colloidal gold surface and, hence, is suitable for label-free detection of molecular or biomolecular binding at the surface of gold colloids.

Biosensing Techniques↗

Electroosmotic flow controllable coating on a capillary surface by a sol-gel process for capillary electrophoresis.

A simple coating procedure employing a sol-gel process to modify the inner surface of a bare fused-silica capillary with a positively charged quaternary ammonium group is established. Scanning electron microscopic studies reveal that a smooth coating with 1 to approximately 2 microm thickness can be obtained at optimized coating conditions. With 40 mM citrate as a running electrolyte, the plot of electroosmotic flow (EOF) versus pH shows a unique three-stage EOF pattern from negative to zero and then to positive over a pH range of 2.5 to 7.0. At pH above 5.5, the direction of the EOF is from the anode to the cathode, as is the case in a bare fused-silica capillary, and the electroosmotic mobility increases as the pH increases. However, the direction of the EOF is reversed at pH below 4.0. Over the pH range of 4.0 to 5.5, zero electroosmotic mobility is obtained. Such a three-stage EOF pattern has been used to separate six aromatic acids under suppressed EOF and to separate nitrate and nitrite with the anions migrating in the same direction as the EOF. The positively charged quaternary ammonium group on the coating was also utilized to minimize the adsorption problem during the separation of five basic drugs under suppressed EOF and during the separation of four basic proteins with the cations migrate in the opposite direction as the EOF. Also, the stability and reproducibility of this column are good.