PubMed Health⌕ Search

Biomedical subjects

Laigao Chen

Publications and source records attributed to Laigao Chen.

4 recordsLinked to original sources

X-ray CT high-density artefact suppression in the presence of bones.

This paper presents a novel method of reducing x-ray CT high-density artefacts generated by metal objects when abundant bone structures are present in the region of interest. This method has an advantage over previously proposed methods since it heavily suppresses the metal artefacts without introducing extra bone artefacts. The method of suppression requires that bone pixels are isolated and segmented by thresholding. Then artificial CT numbers are assigned to the bone pixels so that their projection profiles are smooth and thus can be properly simulated by a polynomial interpolation. The projection profile of the metal object is then removed to fully suppress the artefacts. The resulting processed profile is fed to a reconstruction routine and the previously preserved bone pixels added back. The new method utilizes two important features of the CT image with metal artefacts: (a) metal and bone pixels are not severely affected by the high-density artefacts and (b) the high-density artefacts can be located in specific projection channels in the profile domain, although they are spread out in the image domain. This suppression method solves the problem of CT image artefacts arising from metal objects in the body. It has the potential to greatly improve diagnostic CT imaging in the presence of these objects and treatment planning that utilizes CT for patients with metal applicators (e.g., brachytherapy for cervix cancer and prostate cryotherapy).

Algorithms↗

In vivo micro computed tomography of subchondral bone in the rat after intra-articular administration of monosodium iodoacetate.

Osteoarthritis (OA) is a degenerative disease that is characterized by joint discomfort, loss of articular cartilage, and changes to the subchondral bone. Studies to elucidate the pathophysiology of OA have been hampered by the lack of a rapid, reproducible animal model that mimics the structural changes associated with the disease. A single intra-articular injection of mono-iodoacetate (MIA), an inhibitor of glycolysis, into the femorotibial joint of rodents promotes loss of articular cartilage similar to that noted in human OA. The purpose of the present study was to determine whether in vivo three-dimensional micro computed tomography (microCT) was of use for detecting progressive changes over time to the subchondral bone (femorotibial joint) of Wistar rats treated with a single intra-articular injection of MIA. MIA-treated right knee joints and left contralateral control knee joints were imaged in vivo at 0, 1, 7, 14, 28, and 56 days postinjection by using microCT. Analysis of 50- and 100- micro m resolution images demonstrated that changes to the subchondral bone, as determined by visual and bone mineral density analysis, are apparent by day 14 post-MIA. By day 28, there were marked changes to lateral aspect of the medial tibial plateaus of the subchondral bone in MIA-treated joints. These changes were progressive through day 56. It was concluded that intra-articular injection of MIA induces progressive changes to subchondral bone that can be assessed using in vivo microCT imaging. In light of these data, in vivo microCT imaging represents a valuable tool for investigating bone remolding and has the potential to be used for routine, high-throughput analysis and screening of investigation therapeutics.

Animals↗

General surface reconstruction for cone-beam multislice spiral computed tomography.

A new family of cone-beam reconstruction algorithm, the General Surface Reconstruction (GSR), is proposed and formulated in this paper for multislice spiral computed tomography (CT) reconstructions. It provides a general framework to allow the reconstruction of planar or nonplanar surfaces on a set of rebinned short-scan parallel beam projection data. An iterative surface formation method is proposed as an example to show the possibility to form nonplanar reconstruction surfaces to minimize the adverse effect between the collected cone-beam projection data and the reconstruction surfaces. The improvement in accuracy of the nonplanar surfaces over planar surfaces in the two-dimensional approximate cone-beam reconstructions is mathematically proved and demonstrated using numerical simulations. The proposed GSR algorithm is evaluated by the computer simulation of cone-beam spiral scanning geometry and various mathematical phantoms. The results demonstrate that the GSR algorithm generates much better image quality compared to conventional multislice reconstruction algorithms. For a table speed up to 100 mm per rotation, GSR demonstrates good image quality for both the low-contrast ball phantom and thorax phantom. All other performance parameters are comparable to the single-slice 180 degrees LI (linear interpolation) algorithm, which is considered the "gold standard." GSR also achieves high computing efficiency and good temporal resolution, making it an attractive alternative for the reconstruction of next generation multislice spiral CT data.

Algorithms↗

X-ray CT high-density artefact suppression in cryosurgery.

Advantages of x-ray CT for imaging guidance of cryosurgery include 3D visualization of frozen and unfrozen tissue and calibration of temperature in the tissue water-ice interface (0-10 degrees C) to Hounsfield units. However, use of x-ray CT images and their thermal calibration can be compromised by the cryoprobes generating high-density streak artefacts. A new subtraction technique for artefact suppression is proposed and tested in prostate cryosurgery simulations. By subtracting the measured CT x-ray projection profile without cryoprobes from the profile with cryoprobes plus iceballs, one obtains the combined profile of the cryoprobes and a low value background. Polynomial interpolation to obtain the background profile allows its addition to the original profile without probes. The result may then be fed to a conventional filtered back-projection routine to reconstruct the probe-free image. Finally the cryoprobe pixels in the originally constructed image with probes and iceballs are added back to the probe-free image to get the final artefact-suppressed image. The major advantage of this subtraction technique is that it can successfully suppress the high-density artefacts in bone-abundant body regions such as the pelvis. X-ray CT images of cryoprobe arrays in a homogeneous gelatin phantom and the pelvic region of an anthropomorphic Rando phantom containing a human skeleton were generated. After suppression, cryoprobe metal artefact streaks are reduced and visualization of the positions and dimensions of the cryoprobes are well preserved.

Algorithms↗