PubMed Health⌕ Search

Biomedical subjects

Lan Song

Publications and source records attributed to Lan Song.

7 recordsLinked to original sources

[Comparison of coronary artery bypass graft imaging between 64-slice and 16-slice spiral CT].

OBJECTIVE: To compare the coronary artery bypass graft (CABG) imaging between 16-slice spiral CT and 64-slice spiral CT. METHODS: Totally 27 patients with CABG received multi-slice spiral CT imaging and the results were retrospectively analyzed. Among them, 8 patients received 16-slice spiral CT scanning, 19 patients received 64-slice spiral CT scanning. RESULTS: The evaluability rates of 64-slice spiral CT in evaluating the proximal anastomosis, bypass graft, distal anastomosis, and distal blood vessel were 100%, 100%, 90.2%, and 93.9%, respectively, while those of 16-slice spiral CT were 92.3%, 95.2%, 90.0%, and 90.0%, respectively. The patency rates of the above four aspects of 64-slice spiral CT were 66.7%, 70.0%, 71.7%, and 70.0%, respectively, while those of 16-slice spiral CT were 83.3%, 85.0%, 83.3%, and 88.9% . CONCLUSIONS: 64-slice spiral CT is superior to 16-slice spiral CT in CABG imaging. It can be used as a non-invasive tool for the post-operative follow-up of CABG.

Aged↗

[Comparison of coronary angiography between 64-slice and 16-slice spiral CT].

OBJECTIVE: To compare the image quality and visibility of arteries of 64-slice spiral coronary CT angiography (CTA) with those of 16-slice spiral coronary CTA, and to evaluate the diagnostic accuracy of 64-slice spiral CT for the assessment of coronary artery stenosis. METHODS: Totally 100 patients (Group A) with suspected coronary artery diseases (CAD) were examined by 64-slice spiral CT, 48 of whom also underwent conventional coronary angiography (CAG). Another 100 patients (Group B) with suspected CAD were studied by 16-slice spiral CT. Patients with a heart rate above 70 bpm received oral beta-blockers before the scan. Data were retrospectively analyzed and reviewed by two observers. Image quality was assessed by using a 3-point grading scale from excellent (1) to non-assessable (3) and the rate of displayed coronary branches was calculated. The left main artery (LM), left anterior descending artery (LAD), circumflex artery (CX), and right coronary artery (RCA) were screened for the presence of over 50% stenosis. RESULTS: The mean heart rates of two groups showed no significant difference [(61 +/- 8) bpm vs. (61 +/- 7) bpm, P > 0.05]. The mean scan time of Group A was significantly shorter than that of Group B [(11.9 +/- 0.9) s vs. (22.2 +/- 1.1) s, P < 0.01]. In the evaluation of image quality, better results were obtained in Group A than in Group B (1.20 +/- 0.47 vs. 1.37 +/- 0. 63, P < 0.05). The visibility of proximal arteries was similar between two groups, while the visibility of some distal arteries and small branches was found higher in Group A than in Group B (LAD distal 92% vs. 48%, CX distal 98% vs. 89%, the first obtuse marginal (OMI) 93% vs. 84%, cone branch (CB) 86% vs. 71%, P < 0.05). Compared with CAG, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 64-slice spiral coronary CTA to identify over 50% stenosis were 94.9% (56/59), 93.2% (124/133), 86.2% (56/65), and 97.6% (124/127), respectively. CONCLUSIONS: With higher temporal and spatial resolution, 64-slice spiral CT provides improved image quality and visibility of small branches as compared with 16-slice spiral CT. 64-slice spiral coronary CTA allows reliable non-invasive diagnosis of obvious coronary artery stenosis.

Aged↗

[Assessment of coronary stent lumen visibility and patency by 64-slice spiral CT angiography].

OBJECTIVE: To evaluate the clinical value of assessment of coronary stent patency by 64-slice spiral CT coronary angiography. METHODS: Totally 29 patients (59 stents) were investigated using a retrospective ECG-gated enhanced scan by 64-slice spiral CT at a mean interval of (28.4 +/- 21.2) months after coronary stent implantation. Axial multi-planar reconstruction (MPR) of the stents and curved-planar reconstruction (CPR) through the stents were evaluated for image quality on a 5-point scale (1 = excellent, 5 = uninterpretable) and lumen diameter. Stent lumen diameter was compared with the vessel diameter proximal of the stents to assess the in-stent lumen visibility. Conventional coronary angiography was performed in 5 patients, and 9 stents were evaluated. RESULTS: The image quality was good to excellent on average (scores: 1.94 +/- 0.84), depending on heart rate, breath movement, and stent location. Stent lumen was visible, on average a percentage off (76.1 +/- 11.1)% of the lumen diameter. All the 9 stents were correctly detected as being patent, which was confirmed by conventional coronary angiography. CONCLUSION: 64-slice spiral CT is a useful tool to assess the coronary stent patency.

Adult↗

[Assessment of global left ventricular function with multi-slice spiral computed tomography].

OBJECTIVE: To investigate the value of multi-slice spiral computed tomography (MSCT) in the determination of global left ventricular function. METHODS: Twenty-nine patients with confirmed or suspected coronary heart diseases were imaged with a contrast-enhanced retrospective electrocardiogram (ECG) -gated technique on a 64-slice spiral CT scanner. The data sets were reconstructed at both end-diastolic and end-systolic phases in order to measure left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), left ventricular stroke volume (LVSV), and left ventricular ejection fraction (LVEF). The results were compared with corresponding values obtained from conventional left ventriculography (LVG). RESULTS: LVEDV, LVESV, LVSV, and LVEF obtained with 64-slice spiral CT were significantly correlated with the LVG data (r = 0. 887-0.956, P < 0.001). According to the Bland-Altman approach, the mean differences for LVEDV, LVESV, LVSV, and LVEF were -2.3 ml, 4.1 ml, -6.4 ml, and - 3.5%, respectively. The limits of agreement for LVEDV, LVESV, LVSV, and LVEF were -27.2-22.4 ml, -10.2-18.4 ml, -26.4-13.6 ml, and -9.8%-3.0%, respectively. CONCLUSION: MSCT has clinically acceptable agreement with LVG for the quantification of global left ventricular function.

Adult↗

[Current and future roles of multi-slice spiral computed tomography in noninvasive imaging of coronary arteries].

The emergence of multi-slice spiral computed tomography (MSCT) has a significant influence on cardiovascular imaging. As a noninvasive technique, MSCT is considered suitable for the evaluation of coronary artery stenosis, quantitative and qualitative assessment of plaque, analysis of cardiac function and myocardial perfusion imaging, and determination of the patency of stents or bypass grafts. Recent studies has shown that noninvasive coronary artery imaging with MSCT is a feasible screening test for suspected coronary artery diseases and a valuable follow-up tool for patients who have undergone interventional or surgical therapeutic procedures.

Coronary Angiography↗

[The influence of adrenaline on the expression of TGF-beta1, bFGF and I procollagen for hypertrophic scar].

OBJECTIVE: To investigate the influence of adrenaline on the expression of TGFbeta1, bFGF and procollagen for human normal and hypertrophic scar dermal fibroblasts cultured in vitro. METHODS: Human normal and hypertrophic scar dermal fibroblasts were propagated in a serum-free in vitro model with adrenaline for 24 hours. The human mRNA levels of bFGF, TGF-beta1 and I procollagen in fibroblasts were determined by RT-PCR. Levels of bFGF and TGF-beta1 in the supernatants of fibroblasts cultured in vitro were determined by enzyme-linked immunosorbent assay (ELISA). RESULTS: In our study, adrenaline caused statistically significant increase in the peak levels of bFGF for normal and hypertrophic scar fibroblast cell lines (P < 0.01). It also caused statistically significant decrease in the level of TGF-beta1 for normal and hypertrophic scar fibroblast cell lines. Modulation of normal fibroblasts with 0.05, 0.10 and 0.20 micromol/L adrenaline resulted in a statistically significant (P < 0.01) decrease in the expression of I procollagen mRNA. However, only 0.20 micromol/L adrenaline can decreased the mRNA expression of I procollagen in the hypertrophic scar fibroblasts. CONCLUSIONS: We conclude from these results that adrenaline can increase the production of bFGF and decrease production of TGF-beta1 and I procollagen in human normal dermal and hypertrophic scar fibroblasts cultured in vitro.

Cells, Cultured↗

[An experimental study on the role of protein kinase C in the down-regulation of fibroblast proliferation in normal skin and hyperplastic scar by adrenaline].

OBJECTIVE: To investigate the role of protein kinase C (PKC) in the down-regulation of fibroblast proliferation in normal skin (NFb) and hyperplastic scar (SFb) by adrenaline. METHODS: Human NFb and SFb cells were cultured in vitro. Phentolamine (in final concentrations of 0 and 3 x 10(-6) micromol/L) was added to the culture medium. One hour later, adrenaline in different final concentrations (0.00, 0.05, 0.10, 0.20 micromol/L) was added to the culture medium and incubated for 24 hours. The cellular proliferation activity and cell viability rate were determined with MTT. The cell culture supernatant was harvested for the determination of LDH activity to assess the toxicity of phentolamine and adrenaline. The phosph-PKC activity was determined with Western-blotting and was semiquantitatively analyzed. RESULTS: (1) After stimulation with adrenaline alone, or combined 0.20 micromol/L adrenaline with 3 x 10(-6) micromol/L phentolamine, the cell viability of both NFb and SFb decreased significantly (P < 0.05 or 0.01). (2) There was no difference in the LDH activity between the cells either stimulated by adrenaline in all concentrations or by combination of adrenaline and phentolamine (P > 0.05). (3) The phosphorylation of PKC in NFb and SFb cells stimulated by 0.05, 0.10, 0.20 micromol/L adrenaline was obviously higher than that before stimulation (P < 0.01). When phentolamine in the concentration of 3 x 10(-6) micromol/L was used alone for stimulation, the phosphorylation of PKC in NFb cells (123 +/- 5) was also evidently higher than that before stimulation (80 +/- 5, P < 0.01). But there was no such effect on SFb cells (P > 0.05). When adrenaline in the concentration of 0.05, 0.10 or 0.20 micromol/L was separately added together with phentolamine in the dose of 3 x 10(6) micromol/L for the stimulation, the phosphorylation of PKC in NFb and SFb cells was evidently lower than that when 3 different concentrations of adrenaline was used alone for stimulation (P < 0.01). CONCLUSION: Adrenaline can inhibit the proliferation of NFb and SFb by activating PKC through binding alpha adrenaline receptor.

Cell Proliferation↗