Improved gradient-echo 3D magnetic resonance imaging using pseudo-echoes created by frequency-swept pulses.

Frequency-swept pulses are not typically employed to excite spins in NMR. When used for selective excitation in MRI, such pulses do not produce a proper echo because the phase of the transverse magnetization varies in a quadratic manner across the slice or slab. Previously, frequency-swept pulses such as the chirp pulse have been shown to offer an approach to reduce the peak radiofrequency power required for excitation. It has also been shown that chirp excitation produces a unique type of echo (dubbed "pseudo-echo" here) and images can be generated from the resultant pseudo-echoes using a quadratic reconstruction method (J.G. Pipe, Magn Reson Med 1995;33:24-33). The present work describes a general theory and methods for exciting spins with other types of frequency-swept pulses (HSn pulses), which offer the advantage of delivering better excitation profiles than the chirp pulse. Here, pseudo-echoes are produced with HSn pulses in conventional gradient-echo 3D MRI, and high-quality images are reconstructed using standard fast Fourier transformation. An optional apodization procedure using a sliding window function is also introduced. When the dynamic range of the analog-to-digital converter is limiting, signal-to-noise ratio of pseudo-echo imaging is superior to that obtained with standard excitations.

Brain Mapping↗

9.4T human MRI: preliminary results.

This work reports the preliminary results of the first human images at the new high-field benchmark of 9.4T. A 65-cm-diameter bore magnet was used together with an asymmetric 40-cm-diameter head gradient and shim set. A multichannel transmission line (transverse electromagnetic (TEM)) head coil was driven by a programmable parallel transceiver to control the relative phase and magnitude of each channel independently. These new RF field control methods facilitated compensation for RF artifacts attributed to destructive interference patterns, in order to achieve homogeneous 9.4T head images or localize anatomic targets. Prior to FDA investigational device exemptions (IDEs) and internal review board (IRB)-approved human studies, preliminary RF safety studies were performed on porcine models. These data are reported together with exit interview results from the first 44 human volunteers. Although several points for improvement are discussed, the preliminary results demonstrate the feasibility of safe and successful human imaging at 9.4T.

Burns, Electric↗

On- and off-resonance T(1rho) MRI in acute cerebral ischemia of the rat.

The ability of on-resonance T(1rho) (T(1rho)) and off-resonance T(1rho) (T(1rho)(off)) measurements to indicate acute cerebral ischemia in a rat model of transient middle cerebral artery (MCA) occlusion was investigated at 4.7 T. T(1rho) was determined with B(1) fields of 0.4, 0.8, and 1.6 G, and T(1rho)(off) with five offset frequencies ((Delta)omega) ranging from 0-7.5 kHz at B(1) of 0.4 G, yielding effective B(1) (B(eff)) from 0.4 to 1.8 G. Diffusion, T(1), and T(2) were also quantified. Both T(1rho) and T(1rho)(off) acquired with (Delta)(o)< 2.5 kHz showed positive contrast during the first hours of MCA occlusion in the ischemic tissue delineated by low diffusion. Interestingly, T(1rho)(off) contrast acquired with (Delta)omega > 2.5 kHz was clearly less sensitive to ischemic alterations, and developed with a delayed time course. This discrepancy is thought to be a consequence of the frequency dependency of cross-relaxation during irradiation with spin-lock pulses.

Acute Disease↗

Proton T2 relaxation study of water, N-acetylaspartate, and creatine in human brain using Hahn and Carr-Purcell spin echoes at 4T and 7T.

Carr-Purcell and Hahn spin-echo (SE) measurements were used to estimate the apparent transverse relaxation time constant (T2) of water and metabolites in human brain at 4T and 7T. A significant reduction in the T2 values of proton resonances (water, N-acetylaspartate, and creatine/phosphocreatine) was observed with increasing magnetic field strength and was attributed mainly to increased dynamic dephasing due to increased local susceptibility gradients. At high field, signal loss resulting from T2 decay can be substantially reduced using a Carr-Purcell-type SE sequence.

Aspartic Acid↗

Eliminating spurious lipid sidebands in 1H MRS of breast lesions.

Detecting metabolites in breast lesions by in vivo (1)H MR spectroscopy can be difficult due to the abundance of mobile lipids in the breast which can produce spurious sidebands that interfere with the metabolite signals. Two-dimensional J-resolved spectroscopy has been demonstrated in the brain as a means to eliminate these artifacts from a large water signal; coherent sidebands are resolved at their natural frequencies, leaving the noncoupled metabolite resonances in the zero-frequency trace of the 2D spectrum. This work demonstrates that using the zero-frequency trace-or equivalently the average of spectra acquired with different echo times-can be used to separate noncoupled metabolite signals from the lipid-induced sidebands. This technique is demonstrated with simulations, phantom studies, and in several breast lesions. Compared to the conventional approach using a single echo time, echo time averaging provides increased sensitivity for the study of small and irregularly shaped lesions.

Artifacts↗