PubMed Health⌕ Search

Biomedical subjects

Larry J Davis

Publications and source records attributed to Larry J Davis.

3 recordsLinked to original sources

Longitudinal changes in corneal curvature in keratoconus.

PURPOSE: This study was designed to identify factors that predict longitudinal increases in corneal curvature as measured by the First Definite Apical Clearance Lens (FDACL) and flatter keratometric reading (Flat K) in keratoconus. METHODS: The Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study is a long-te rm evaluation of the natural history of keratoconus involving 1209 patients. This report uses 8 years of follow-up data from 1032 patients who had penetrating keratoplasty in neither eye at baseline and who provided enough data to compute the slope of the change with time in the FDACL or the Flat K. Outcome measures included the aforementioned slopes and whether the FDACL or the Flat K increased by 3.00 or more diopters (D) in at least 1 eye. RESULTS: At CLEK Study entry, patients were aged 38.9 +/- 10.8 years. Overall, 44.3% of them were women, and 69.3% of them were white. The slope of the change in FDACL (0.18 +/- 0.60 D/y) and Flat K (0.20 +/- 0.80 D) during 8 years translates into expected 8-year increases of 1.44 D in FDACL and 1.60 D in Flat K. Increases of > or = 3.00 D in either eye had an 8-year incidence of 24.8% for FDACL and 24.1% for Flat K. Independent predictors of increased FDACL included younger age, poorer baseline high-contrast manifest refraction visual acuity, and non-white race. Younger age and poorer high-contrast manifest refraction visual acuity were independent predictors of a >3.00-D increase for both FDACL and Flat K. CONCLUSION: CLEK patients exhibited a slow but clear increase in corneal curvature. Younger age and poorer high-contrast manifest refraction visual acuity at baseline predicted the rate of change in corneal curvature.

Adult↗

Longitudinal changes in visual acuity in keratoconus.

PURPOSE: The present investigation aimed to identify factors that predict reduced visual acuity in keratoconus from a prospective, longitudinal study. METHODS: This report from the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study used 7 years of follow-up data from 953 CLEK subjects who did not have penetrating keratoplasty in either eye at baseline and who provided enough data to compute the slope of the change over time in high- or low-contrast best-corrected visual acuity (BCVA). Outcome measures included these slopes and whether the number of letters correctly read decreased by 10 letters or more in at least one eye in 7 years. RESULTS: Mean age of the subjects at the first follow-up visit was 40.2 +/- 11.0 years (mean +/- SD). Overall, 44.4% were female, and 71.9% were white. The slope of the change in high- and low-contrast BCVA (-0.29 +/- 1.5 and -0.58 +/- 1.7 letters correct/year, respectively) translated into expected 7-year decreases of 2.03 high- and 4.06 low-contrast letters correct. High- and low-contrast visual acuity decreases of 10 or more letters correct occurred in 19.0% and 30.8% of subjects, respectively. Independent predictors of reduced high- and low-contrast BCVA included better baseline acuity, steeper first definite apical clearance lens (FDACL), and fundus abnormalities. Each diopter of steeper baseline FDACL predicted an increased deterioration of 0.49 high- and 0.63 low-contrast letters correct. CONCLUSIONS: CLEK Study subjects with keratoconus exhibited a slow but clear decrease in BCVA during follow-up, with low-contrast acuity deteriorating more rapidly than high-contrast. Better baseline BCVA, steeper FDACL, and fundus abnormalities were predictive of greater acuity loss with time.

Adult↗

Repeatability of corneal topography measurement in keratoconus with the TMS-1.

PURPOSE: The purpose of this study was to report the test-retest variability of simulated indices derived from the TMS-1 topography instrument (Tomey Technology, Waltham, MA) in keratoconus subjects enrolled in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study. METHODS: Four images were taken at an initial visit and at a repeat visit several weeks later. From these images, 17 indices were simulated from published formulas. Mixed-model analysis was used on test-retest data from the TMS-1 videokeratography instrument during the baseline year. This analysis yields estimates of within- and between-visit variability. RESULTS: Repeatability analysis revealed that within-visit standard errors were 1.0 to 5.9 times greater in keratoconus eyes than in normal controls when two images were analyzed from each visit. These values changed only slightly when more images were used. The ratio of between-visit standard errors of the indices were nearly equally greater than normal controls for (0.9-4.6 and 0.9-4.3) two images per eye and all images per eye, respectively. CONCLUSIONS: These results suggest that the repeatability of simulated indices derived from TMS-1 topography in keratoconus subjects is poorer than in normal controls.

Algorithms↗