PubMed Health⌕ Search

Biomedical subjects

Lars F Norum

Publications and source records attributed to Lars F Norum.

2 recordsLinked to original sources

Immunometric assay interference: incidence and prevention.

BACKGROUND: The primary aim of the study was to reduce interference in an in-house two-site, two-step immunometric assay. METHODS: In the running laboratory routine, 11 261 samples were tested with a carcinoembryonic antigen (CEA) assay with bovine immunoglobulin but no murine immunoglobulins in the buffer, in parallel to our routine CEA assay, using 15 mg/L heat-treated nonspecific murine immunoglobulin (MAK33) in the buffer and with the Fc fragments removed from the capture antibody. RESULTS: The frequency of interference was estimated to be 4.0% (95% confidence interval, 3.3-4.7%). The addition of 15 mg/L native MAK33 had little effect (frequency, 3.9%; 95% confidence interval, 3.2-4.6%), whereas adding 15 mg/L heat-treated MAK33 reduced interference to 0.86% (0.61-1.12%), and adding 50 mg/L reduced it further to 0.06% (0-0.13%). Removing the Fc fragments by itself reduced interference to 0.10% (0.02-0.19%). There were no statistically significant differences for age (P <0.23) or gender (P <0.40) between patients with interference (n = 210) and a randomly selected interference-negative control group (n = 186). Interference was not constant in patients: 15 of 25 individuals positive for interference and with four or more samples screened for interference had an interference-negative sample either before or after the peak of interference. CONCLUSIONS: In a two-site, two-step immunometric assay using mouse monoclonal antibodies, use of heat-treated nonspecific murine immunoglobulin in the buffer or removal of the Fc fragment from the capture antibody could improve performance.

Animals↗

MUC1 serum assays in breast cancer: tumor specificities and reference levels.

The aim of the study was to establish reference ranges and to explore the tumor specificities of two automated assays for MUC1. Sera from 124 female blood donors, 144 patients with benign disease of the breast, 69 patients with stage I, 75 with stage II, 89 with stage III and 38 patients with stage IV breast cancer were analyzed for MUC1 levels using two automated immunometric assays employing assay antibody pairs Ma695/Ma552 and BC2/GP1.4, respectively. All subjects were female. The Ma695/Ma552 assay yielded means of 13.86 (SD 6.55) kU/l for blood donors, 15.98 (SD 8.31) kU/l for benign disease, 15.83 (SD 7.92) kU/l for stage I, 15.01 (SD 8.03) kU/l for stage II, 33.80 (SD 66.53) kU/l for stage III and 469.22 (SD 906.61) kU/l for stage IV breast cancer. The BC2/GP1.4 assay gave means of 12.00 (SD 6.41) kU/l for blood donors, 14.68 (SD 9.33) kU/l for benign disease, 14.13 (SD 8.12) kU/l for stage I, 12.10 (SD 6.61) kU/l for stage II, 19.80 (SD 29.05) kU/l for stage III and 191.04 (SD 527.16) kU/l for stage IV breast cancer. Patients with benign diseases of the breast had slightly higher values than female blood donors with both assays leading to correspondingly different reference ranges. The Ma695/Ma552 assay had higher specificity for tumor MUC1 than the BC2/GP1.4 assay for all stages, and the study thus confirms the differences in tumor specificity for MUC1 assays.

Adult↗