PubMed Health⌕ Search

Biomedical subjects

Lars Friberg

Publications and source records attributed to Lars Friberg.

4 recordsLinked to original sources

Clinical impact of diagnostic SPET investigations with a dopamine re-uptake ligand.

The diagnosis of Parkinson's disease is based on clinical features with pathological verification. However, autopsy has been found to confirm a specialist diagnosis in only about 75% of cases. Especially early in the course of the disease, the clinical diagnosis can be difficult. Imaging of presynaptic dopamine transporters (DAT receptors) has provided a possible diagnostic probe in the evaluation of Parkinson's disease. The cocaine analogue [(123)I]-2-beta-carboxymethoxy-3-beta(4-iodophenyl)tropane ([(123)I]-beta-CIT) is one of several radioligands that have been developed for single-photon emission tomography (SPET). The purpose of this study was to evaluate the impact of [(123)I]-beta-CIT SPET on the diagnosis and clinical management of patients with a primary, tentative diagnosis of parkinsonism. We undertook a retrospective evaluation of the clinical records of 90 consecutive patients referred to [(123)I]-beta-CIT SPET from the neurological department, Bispebjerg Hospital. In 58 subjects the scans revealed altered tracer uptake consistent with Parkinson's disease, progressive supranuclear palsy and multiple system atrophy. A significant change in the management or treatment because of the scan was found in 25 patients (28%). The sensitivity of the examination was 97% and the specificity 83%. In conclusion, a significant clinical impact of DAT receptor SPET imaging was found. DAT receptor imaging is a useful diagnostic probe in patients with a possible diagnosis of parkinsonism.

Adult↗

Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia.

BACKGROUND: The purpose of this study was to evaluate the possibility of measuring cardiac output during positron emission tomography (PET) examination of myocardial perfusion with nitrogen 13 ammonia. METHODS AND RESULTS: In 7 patients undergoing right-sided cardiac catheterization for evaluation of heart failure and 6 patients who had undergone heart transplantation, a thermodilution catheter for continuous measurement of cardiac output was inserted. An N-13 ammonia scan of the heart was subsequently performed, and with use of factor analysis, the time-activity curve from the right ventricle was derived from the dynamic image sequence. The PET-derived cardiac output was subsequently obtained according to the Stewart-Hamilton principle as the amount of injected tracer divided by the area under the time-activity curve. PET-acquired cardiac output measurements correlated closely with the invasively determined values for a wide range of cardiac output values (P < .0001). The mean difference was 0.12 L/min, with an SD of 0.74 L/min. The interobserver variation was low, with a mean difference of 0.06 L/min and an SD of 0.46 L/min. CONCLUSIONS: Cardiac output determination with N-13 ammonia and PET appears to be both accurate and precise and can be performed simultaneously with measurement of myocardial perfusion.

Adult↗