Lars Wigström

Publications and source records attributed to Lars Wigström.

8 recordsLinked to original sources

Five-dimensional MRI incorporating simultaneous resolution of cardiac and respiratory phases for volumetric imaging.

PURPOSE: To develop a new volumetric imaging method resolved over both the cardiac and respiratory cycles, to enable future physiological and pathophysiological studies of respiratory-related cardiac motion. MATERIALS AND METHODS: An acquisition scheme is proposed whereby the k-space acquisition order is controlled in real-time by the current cardiac and respiratory phases. To reduce eddy-current effects induced by sudden jumps in k-space, the acquisition order is further optimized by the use of a Hilbert curve trajectory in the k(y)-k(z) plane. A complete three-dimensional (3D) k-space is acquired for all combinations of cardiac and respiratory phases, yielding a five-dimensional (5D) data set after retrospective reconstruction. RESULTS: Left (LV) and right ventricular (RV) wall excursion was measured in a healthy volunteer. Diastolic LV diameter was shown to increase during expiration and decrease during inspiration, as expected from previous echocardiography studies. The LV volume was estimated for all cardiac and respiratory phases with the use of a fully 3D segmentation tool. The results confirmed that the diastolic LV volume increased during expiration and decreased during inspiration. CONCLUSION: With its ability to measure motion anywhere in the heart, the described technique provides a promising approach for in-depth description of interventricular coupling, including 3D ventricular volumes, during both the cardiac and respiratory cycles.

Cardiac Volume↗

Towards cardiac C-arm computed tomography.

Cardiac interventional procedures would benefit tremendously from sophisticated three-dimensional image guidance. Such procedures are typically performed with C-arm angiography systems, and tomographic imaging is currently available only by using preprocedural computed tomography (CT) or magnetic resonance imaging (MRI) scans. Recent developments in C-arm CT (Angiographic CT) allow three-dimensional (3-D) imaging of low contrast details with angiography imaging systems for noncardiac applications. We propose a new approach for cardiac imaging that takes advantage of this improved contrast resolution and is based on intravenous contrast injection. The method is an analogue to multisegment reconstruction in cardiac CT adapted to the much slower rotational speed of C-arm CT. Motion of the heart is considered in the reconstruction process by retrospective electrocardiogram (ECG)-gating, using only projections acquired at a similar heart phase. A series of N almost identical rotational acquisitions is performed at different heart phases to obtain a complete data set at a minimum temporal resolution of 1/N of the heart cycle time. First results in simulation, using an experimental phantom, and in preclinical in vivo studies showed that excellent image quality can be achieved.

Algorithms↗

Comparison of different methods for combining phase-contrast images obtained with multiple coils.

The ability to determine coil sensitivities implies that a method optimized in terms of maximized signal-to-noise ratio (SNR) can be applied to the combination of multiple coil images. An optimization of SNR subsequently results in a minimized variance in quantitative velocity measurements using phase-contrast imaging. When coil sensitivities are unknown, the weighted mean method, utilizing the square of the signal magnitude as weights, is suitable for combination of multiple phase images. In this study, the optimized method using estimated coil sensitivities was compared to the weighted mean method both theoretically and experimentally. It is shown that absence of noise correlation between the different coil images implies no difference between the methods regarding the variance of the phase. In the practical situation, noise correlation does exist, implying an opportunity for further reduction of phase variance using the optimized method. In vitro and in vivo studies showed, however, no significant difference between the two methods studied.

Aorta↗

Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging: implications for aortic valve-sparing surgery.

OBJECTIVE: Sparing the aortic valve has become a surgical option for patients who require repair of aortic root ectasia and have normal valve leaflets. Surgical approaches to valve sparing differ with regard to preservation of the native sinuses of Valsalva. The role of the sinuses and the importance of maintaining them remain controversial. METHODS: By using a time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging technique, aortic root and aortic blood velocity data were acquired from 2 patients with Marfan syndrome 6 months after aortic valve-sparing surgery with straight Dacron grafts and contrasted with data from 6 normal volunteers. RESULTS: In normal aortas vortical blood flow became apparent in the individual sinuses after peak systole. The vortices filled the available space behind the valve leaflets and persisted until diastole, expanding and moving inward during aortic valve closure. In contrast, no vortices were observed in the postoperative patients with Marfan syndrome with negligible sinuses. CONCLUSIONS: Changes in supravalvular flow accompany loss of sinus architecture. Whether the presence, size, and velocity of supravalvular vortices affects the function or durability of the preserved aortic valve remains to be studied.

Adult↗

Three-directional myocardial motion assessed using 3D phase contrast MRI.

Regional myocardial function is a complex entity consisting of motion in three dimensions (3D). Besides magnetic resonance imaging (MRI), no other noninvasive technique can give a true 3D description of cardiac motion. Using a time-resolved 3D phase contrast technique, three-dimensional image volumes containing myocardial velocity data in six normal volunteers were acquired. Coordinates and velocity information were extracted from nine points placed in different myocardial segments in the left ventricle (LV), and decomposed into longitudinal (V(L)), radial (V(R)), and circumferential (V(C)) velocity components. Our findings confirm a longitudinal apex-to-base gradient for the LV, with only a small motion of the apex. The mean velocity for V(L) for all the basal segments was higher compared to the midsegments during systole [3.5+/-1.2 vs. 2.5+/-1.7 cm/s (p<0.01)], early filling [-6.9+/-1.8 vs. -4.9+/-1.8 cm/s (p<0.001)], and during atrial contraction [-2.2+/-1.4 vs. -1.6+/-1.3 cm/s (p<0.05)]. A similar pattern was observed when comparing velocities from the midsegments to the apex. Radial velocity was higher during early filling in the midportion of the lateral [-4.9+/-2.7 vs. -3.2+/-1.6 cm/s (p<0.05)] wall compared to the basal segments, no difference was observed for the septal [-2.0+/-1.5 vs. -0.3+/-2.5 cm/s (p=0.15)], anterior [-5.8+/-3.3 vs. -4.0+/-1.7 cm/s (p=0.17)], and posterior [-2.3+/-2.1 vs. -2.5+/-1.0 cm/s (p=0.78)] walls. When observing the myocardial velocity in a single point and visualizing the movement of the main direction of the velocities in this point as vectors in velocity vector plots like planes, it is clear that myocardial movement is by no means one dimensional. In conclusion, our time-resolved 3D, phase contrast MRI technique makes it feasible to extract myocardial velocities from anywhere in the myocardium, including all three velocity components without the need for positioning any slices at the time of acquisition.

Adult↗

Accuracy and reproducibility in phase contrast imaging using SENSE.

The purpose of this study was to evaluate the accuracy and reproducibility of phase contrast imaging using the sensitivity encoding (SENSE) method at different reduction factors. Analytical expressions were derived that state how reproducibility is influenced for velocity and flow measurements. Computer simulations, and in vitro and in vivo studies were performed in order to validate these expressions and to assess how accuracy is affected when different reduction factors are applied. It was shown that reproducibility depends on the reduction and geometry factors. Since the geometry factor varies spatially, so does the reproducibility for phase contrast imaging. In areas with high geometry factors, the standard deviation (SD) may become so large that aliasing occurs. The accuracy of phase contrast imaging is not influenced directly when SENSE is used, but may be indirectly influenced due to high SDs of the measured phase that may subsequently cause aliasing. The current results show that it is possible to achieve accurate flow measurements even at high reduction factors. By taking the geometry factor into account, it may be possible to find areas where phase contrast imaging is accurate even at high reduction factors.

Blood Flow Velocity↗

Correction for displacement artifacts in 3D phase contrast imaging.

PURPOSE: To correct for displacement artifacts in 3D phase contrast imaging. MATERIALS AND METHODS: A 3D phase contrast pulse sequence was modified so that displacements of velocity measurements were restricted to one direction. By applying a postprocessing method, displaced measurements could be traced back to their accurate positions. Flow studies were performed using a phantom that generated flow through a stenosis, directed oblique relative to the phase and frequency encoding directions. Velocity profiles and streamline visualization were used to compare displaced and corrected velocity data to a reference. RESULTS: Velocity profiles obtained from the original measurement showed skewed profiles due to the displacement artifact, both at close proximity to the orifice as well as further downstream. After correction, concordance with the reference improved considerably. CONCLUSION: The displacement artifact, which restricts the accuracy of phase contrast measurements, can be corrected for using the proposed method. Correction of the phase contrast velocity data may improve the accuracy of subsequent flow analysis and visualization.

Artifacts↗

Kinematics of the heart: strain-rate imaging from time-resolved three-dimensional phase contrast MRI.

A four-dimensional mapping (three spatial dimensions + time) of myocardial strain-rate would help to describe the mechanical properties of the myocardium, which affect important physiological factors such as the pumping performance of the ventricles. Strain-rate represents the local instantaneous deformation of the myocardium and can be calculated from the spatial gradients of the velocity field. Strain-rate has previously been calculated using one-dimensional (ultrasound) or two-dimensional (2-D) magnetic resonance imaging) techniques. However, this assumes that myocardial motion only occurs in one direction or in one plane, respectively. This paper presents a method for calculation of the time-resolved three-dimensional (3-D) strain-rate tensor using velocity vector information in a 3-D spatial grid during the whole cardiac cycle. The strain-rate tensor provides full information of both magnitude and direction of the instantaneous deformation of the myocardium. A method for visualization of the full 3-D tensor is also suggested. The tensors are visualized using ellipsoids, which display the principal directions of strain-rate and the ratio between strain-rate magnitude in each direction. The presented method reveals the principal strain-rate directions without a priori knowledge of myocardial motion directions.

Biomechanical Phenomena↗