Lasse Jyrkinen

Publications and source records attributed to Lasse Jyrkinen.

6 recordsLinked to original sources

MR imaging-guided laser ablation of osteoid osteomas with use of optical instrument guidance at 0.23 T.

The purpose of this study was to determine the feasibility and features of low-field MR imaging in performing interstitial laser ablation of osteoid osteomas. Between September 2001 and April 2002, five consecutive patients with clinical and imaging findings suggesting osteoid osteoma and referred for removal of osteoid osteoma were treated with interstitial laser treatment. A low-field open-configuration MRI scanner (0.23 T, Outlook Proview, Philips Medical Systems, Finland) with optical instrument guidance hardware and software was used. Laser device used was of ND-Yag type (Fibertom medilas, Dornier Medizin Technik, Germany). A bare laser fiber (Dornier Medizin Technik, Germany) with a diameter of 400 microm was used. Completely balanced steady-state (CBASS; true fast imaging with steady precession) imaging was used for lesion localization, instrument guidance, and thermal monitoring. A 14-G (Cook Medical, USA) bone biopsy drill was used for initial approach. Laser treatment was conducted through the biopsy canal. All the lesions were successfully localized, targeted, and treated under MRI guidance. All the patients were symptom free 3 weeks and 3 months after the treatment. There was one recurrence reported during follow-up (6 months). The MRI-guided percutaneous interstitial laser ablation of osteoid osteomas seems to be a feasible treatment mode.

Adolescent↗

Percutaneous MR-guided discography in a low-field system using optical instrument tracking: a feasibility study.

PURPOSE: To evaluate the feasibility of MRI-guided discography with optical tracking. MATERIAL AND METHODS: 12 consecutive patients who had a clinical suspicion of lumbar discogenic pain and/or suggestive finding of disc degeneration in imaging studies (MRI, CT, plain radiography) underwent MRI-guided discography in order to determine possible pain provocation during puncture and contrast injection. An 0.23 T open configuration MRI device with interventional tools (Outlook Proview, Philips Medical Systems, MR Technologies, Finland) was used in procedural imaging and instrument guidance. An optical guidance tool was attached to the MRI compatible needle (Chiba-type MReye, Cook, Bloomington, IN). After initial disc puncture, 1-2 mL of gadolinium contrast (Magnevist, 469 mg/mL, Schering AG, Germany) saline mixture (1:8) was injected into the disc. Immediately after injection, sagittal FE T1 weighted images were obtained to verify the final position of the needle and formation of the MRI discogram. On nine patients, additional noncontrast sagittal fast spin echo (FSE) T1, FSE T2, and axial 3D T1 gradient echo imaging was performed before and after contrast media injection to obtain MRI discograms. RESULTS: Overall, 35 disc punctures were initialized and 34 MRI discograms were obtained. In all punctures, a positive or negative pain response was obtained. The average time for performing a procedure for three discs was 1 hour 25 minutes (minimum 45 minutes, maximum 2 hours, 15 minutes), and the average number of imaging sequences used for a puncturing one disc was 12. On one disc, the puncture failed and a discogram was not acquired. There was one complication (disc collapse) reported during follow-up. CONCLUSION: Our results show that MRI guidance in performing discography is accurate and relatively safe. It is a technically comparable method to CT-guidance or fluoroscopy.

Adult↗

A portable diagnostic workstation based on a Webpad: implementation and evaluation.

A wireless hand-held Webpad device was used to review a sample set of cranial computerized tomography (CT) studies to assess its diagnostic capabilities and its feasibility as a portable diagnostic workstation for radiology. The data-set consisted of 30 head CT studies of emergency cases. Two neuroradiologists and a senior radiologist participated in the evaluation of the portable workstation. They used a Web-based viewer that we developed, which provided all the major functionalities required for radiological image review. The reported radiological findings and diagnoses were compared with a gold standard, comprising a set of diagnoses previously formulated by a consensus panel of radiologists who had reviewed the original studies. The diagnoses made using the Webpad were correct (no major discrepancies) in 82 out of 90 interpretations (91%), which is comparable to the accuracy reported in image review with a conventional radiological workstation. The average total working time per diagnosis was 5 min 25 s (range 2-12 min). The simplicity of use of the system and its low cost make it suitable for distributing radiological studies within hospital facilities.

Adolescent↗

MRI-guided periradicular nerve root infiltration therapy in low-field (0.23-T) MRI system using optical instrument tracking.

The purpose of this study was to evaluate the feasibility of the MRI-guided periradicular nerve root infiltration therapy. Sixty-seven nerve root infiltrations under MRI guidance were done for 61 patients suffering from lumbosacral radicular pain. Informed consent was acquired from all patients. A 0.23-T open-MRI scanner with interventional tools (Outlook Proview, Philips Medical Systems, MR Technologies, Finland) was used. A surface coil was used in all cases. Nerve root infiltration was performed with MRI-compatible 20-G needle (Chiba type MReye, Cook, Bloomington, Ind.; or Manan type, MD Tech, Florida). The evaluation of clinical outcome was achieved with 6 months of clinical follow-up and questionnaire. The effect of nerve root infiltration to the radicular pain was graded: 1=good to excellent, i.e., no pain or not disturbing pain allowing normal physical activity at 3 months from the procedure; 2=temporary, i.e., temporary relief of pain; 3=no relief of pain; and 4=worsening of pain. As an adjunct to MRI-guided positioning of the needle the correct needle localization by the nerve root was confirmed with saline injection to nerve root channel and single-shot fast spin echo (SSFSE) imaging. The MRI guidance allowed adequate needle positioning in all but 1 case (98.5%). This failure was caused by degeneration-induced changes in anatomy. Of patients, 51.5% had good to excellent effect with regard to radicular pain from the procedure, 22.7% had temporary relief, 21.2% had no effect, and in 4.5% the pain worsened. Our results show that MRI guidance is accurate and safe in performing nerve root infiltration at lumbosacral area. The results of radicular pain relief from nerve root infiltration are comparable to CT or fluoroscopy studies on the subject.

Adult↗

MR-guided bone biopsy: preliminary report of a new guiding method.

PURPOSE: To evaluate the feasibility of a new MR compatible optical tracking guided bone biopsy system. MATERIALS AND METHODS: Wireless optical tracker elements were connected to a bone biopsy set. Biopsies of five different anatomic areas and lesions varying from 9 mm to 40 mm (mean 25 mm) in size, were performed. RESULTS: We were able to perform the biopsies in all cases, and the samples allowed for a pathologic diagnosis. The procedure time was limited to less than 40 minutes, and no complications occurred. CONCLUSION: MR-guided bone biopsy with this new guiding system was a feasible and fast procedure that did not compromise the usability of the bone biopsy set.

Biopsy↗

MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking.

The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial.

Biopsy↗