PubMed Health⌕ Search

Biomedical subjects

Laura A Dawson

Publications and source records attributed to Laura A Dawson.

At least 19 recordsLinked to original sources

Acceleration of hyperfractionated chemoradiation regimen for advanced head and neck cancer.

BACKGROUND: Our aim was to evaluate the acceleration of a hyperfractionated, concurrent chemoradiation regimen (HxCRT) for advanced head and neck squamous cell carcinoma (HNSCC). METHODS: Patients with unresectable HNSCC were treated based on a previously published HxCRT regimen: 1.25 Gy twice daily to 70 Gy concurrent with cisplatin 12 mg/m(2)/day and 5-fluorouracil 600 mg/m(2)/day for 5 days, weeks 1, 5. This regimen was accelerated in this series by shortening the treatment from 7 to 6 weeks by omitting the planned mid-treatment 1-week break. RESULTS: Forty-six patients with T3-4/N3 disease were treated. The main acute toxicity was pharyngeal. Median weight change during therapy in patients with and without enteral feeding tubes was -3.8% and -7.9%, respectively (p = .08). Fifteen percent had late grade III pharyngeal toxicity. Local/regional and distant failure rates were 28% and 17%, respectively; 52% are alive without evidence of disease. CONCLUSIONS: In nonresectable HNSCC, acceleration of the HxCRT regimen is feasible, requiring enteral feeding tubes during therapy in most patients.

Adult↗

Prospective comparison of computed tomography and magnetic resonance imaging for liver cancer delineation using deformable image registration.

PURPOSE: The aim of this study was to compare magnetic resonance imaging (MRI) with computed tomography (CT) for liver cancer tumor definition for high-precision radiotherapy planning. METHODS AND MATERIALS: Diagnostic quality MRI scans and triphasic CT scans, with the liver immobilized in exhale, were obtained at the time of radiation planning for 26 patients with unresectable liver metastases (n = 8), hepatocellular carcinoma (n = 10), and cholangiocarcinoma (n = 8). On the CT and MRI series best demonstrating the tumor, the liver and gross tumor volumes (GTVs) were contoured, and intrahepatic anatomic reference points were identified. Deformable registration was used to register the liver from the CT with that from the MRI. RESULTS: A difference in the number of tumor foci was seen on CT vs. MRI in 5 patients with hepatocellular carcinoma: MRI showed more foci in 3 patients, CT in 2. After deformable registration of the livers, the population median of the average distance between the CT tumor surface and MRI tumor surface was 3.7 mm (2.2-21.3 mm). The median percentage of tumor surface area that differed by > or = 5 mm was 26% (1-86%). Median percentage concordance volumes were 81% (77-86%) in metastases, 77% (60-88%) in hepatocellular carcinoma and 64% (25-85%) in cholangiocarcinoma. CONCLUSION: Differences between MRI-defined liver cancer GTVs and CT-defined GTVs can be substantial and are more common in primary liver cancer.

Carcinoma, Hepatocellular↗

Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy.

PURPOSE: To evaluate the residual error in liver position using breath-hold kilovoltage (kV) cone-beam computed tomography (CT) following on-line orthogonal megavoltage (MV) image-guided breath-hold liver cancer conformal radiotherapy. METHODS AND MATERIALS: Thirteen patients with liver cancer treated with 6-fraction breath-hold conformal radiotherapy were investigated. Before each fraction, orthogonal MV images were obtained during exhale breath-hold, with repositioning for offsets>3 mm, using the diaphragm for cranio-caudal (CC) alignment and vertebral bodies for medial-lateral (ML) and anterior posterior (AP) alignment. After repositioning, repeat orthogonal MV images, orthogonal kV fluoroscopic movies, and kV cone-beam CTs were obtained in exhale breath-hold. The cone-beam CT livers were registered to the planning CT liver to obtain the residual setup error in liver position. RESULTS: After repositioning, 78 orthogonal MV image pairs, 61 orthogonal kV image pairs, and 72 kV cone-beam CT scans were obtained. Population random setup errors (sigma) in liver position were 2.7 mm (CC), 2.3 mm (ML), and 3.0 mm (AP), and systematic errors (Sigma) were 1.1 mm, 1.9 mm, and 1.3 mm in the superior, medial, and posterior directions. Liver offsets>5 mm were observed in 33% of cases; offsets>10 mm and liver deformation>5 mm were observed in a minority of patients. CONCLUSIONS: Liver position after radiation therapy guided with MV orthogonal imaging was within 5 mm of planned position in the majority of patients. kV cone-beam CT image guidance should improve accuracy with reduced dose compared with orthogonal MV image guidance for liver cancer radiation therapy.

Carcinoma, Hepatocellular↗

Ten-year multi-institutional results of breast-conserving surgery and radiotherapy in BRCA1/2-associated stage I/II breast cancer.

PURPOSE: We compared the outcome of breast-conserving surgery and radiotherapy in BRCA1/2 mutation carriers with breast cancer versus that of matched sporadic controls. METHODS: A total of 160 BRCA1/2 mutation carriers with breast cancer were matched with 445 controls with sporadic breast cancer. Primary end points were rates of in-breast tumor recurrence (IBTR) and contralateral breast cancers (CBCs). Median follow-up was 7.9 years for mutation carriers and 6.7 years for controls. RESULTS: There was no significant difference in IBTR overall between carriers and controls; 10- and 15-year estimates were 12% and 24% for carriers and 9% and 17% for controls, respectively (hazard ratio [HR], 1.37; P = .19). Multivariate analyses for IBTR found BRCA1/2 mutation status to be an independent predictor of IBTR when carriers who had undergone oophorectomy were removed from analysis (HR, 1.99; P = .04); the incidence of IBTR in carriers who had undergone oophorectomy was not significantly different from that in sporadic controls (P = .37). CBCs were significantly greater in carriers versus controls, with 10- and 15-year estimates of 26% and 39% for carriers and 3% and 7% for controls, respectively (HR, 10.43; P < .0001). Tamoxifen use significantly reduced risk of CBCs in mutation carriers (HR, 0.31; P = .05). CONCLUSION: IBTR risk at 10 years is similar in BRCA1/2 carriers treated with breast conservation surgery who undergo oophorectomy versus sporadic controls. As expected, CBCs are significantly increased in carriers. Although the incidence of CBCs was significantly reduced in mutation carriers who received tamoxifen, this rate remained significantly greater than in controls. Additional strategies are needed to reduce contralateral cancers in these high-risk women.

Adult↗

Radiation therapy for hepatocellular carcinoma: from palliation to cure.

Technologic advances have provided the means to deliver tumoricidal doses of radiation therapy (RT) to patients with unresectable hepatocellular carcinoma (HCC) while avoiding critical normal tissues, providing the opportunity to use RT for curative intent treatment of HCC. For the current report, the expanded role of external beam RT in the setting of HCC from palliation to cure was reviewed. A systematic literature search was undertaken using the MEDLINE data base and secondary references to identify peer-reviewed, English-language articles that reported clinical outcomes after external beam RT alone or in combination with other treatments for HCC. Abstracts from the 2005 American Society of Clinical Oncology, American Society for Therapeutic Radiology and Oncology, American Gastrointestinal Association, and Society of Surgical Oncology Gastrointestinal Cancer Symposium also were included in the search. More than 60 articles reporting on clinical outcomes among patients who received RT for HCC have been published since 1990, including 20 articles that described unique sets of at least 15 patients. RT was used for palliation, to improve local control, and with curative intent in a wide spectrum of patients who most often were unsuitable for surgery and other treatments. Pain reduction following RT was noted in approximately 75% of patients with bone metastases from HCC who received RT. For patients with liver-confined disease treated with conformal RT, proton beam RT, and/or image guided RT with or without transarterial chemoembolization (TACE), local control response rates ranged from 40% to 90%, and the median survival ranges from 10 months to 25 months. For patients with HCC who had portal vein thrombus, the median survival after RT to treat the thrombus and/or the hepatic tumor with or without TACE ranged from 5.3 months to 9.7 months. Although outcomes after high-dose conformal RT for liver-confined HCC were excellent, the potential survival benefit of RT should be tested in randomized controlled trials that require international collaboration.

Carcinoma, Hepatocellular↗

Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy.

PURPOSE: To measure the intrabreath-hold liver motion and the intrafraction and interfraction reproducibility of liver position relative to vertebral bodies using an active breathing coordinator (ABC) in patients with unresectable liver cancer treated with hypofractionated stereotactic body radiation therapy (SBRT). METHODS: Tolerability of ABC and organ motion during ABC was assessed using kV fluoroscopy in 34 patients. For patients treated with ABC, repeat breath-hold CT scans in the ABC breath-hold position were acquired at simulation to estimate the volumetric intrafraction reproducibility of the liver relative to the vertebral bodies. In addition, preceding each radiation therapy fraction, with the liver immobilized using ABC, repeat anteroposterior (AP) megavoltage verification images were obtained. Off-line alignments were completed to determine intrafraction reproducibility (from repeat images obtained before one treatment) and interfraction reproducibility (from comparisons of the final image for each fraction with the AP) of diaphragm position relative to vertebral bodies. For each image set, the vertebral bodies were aligned, and the resultant craniocaudal (CC) offset in diaphragm position was measured. Liver position during ABC was also evaluated from kV fluoroscopy acquired at the time of simulation, kV fluoroscopy at the time of treatment, and from MV beam's-eye view movie loops acquired during treatment. RESULTS: Twenty-one of 34 patients were screened to be suitable for ABC. The average free breathing range of these patients was 13 mm (range, 5-1 mm). Fluoroscopy revealed that the average maximal diaphragm motion during ABC breath-hold was 1.4 mm (range, 0-3.4 mm). The MV treatment movie loops confirmed diaphragm stability during treatment. For a measure of intrafraction reproducibility, an analysis of 36 repeat ABC computed tomography (CT) scans in 14 patients was conducted. The average mean difference in the liver surface position was -0.9 mm, -0.5 mm, and 0.2 mm in the CC, AP, and medial-lateral (ML) directions, with a standard deviation of 1.5 mm, 1.5 mm, and 1.5 mm, respectively. Ninety-five percent of the liver surface had an absolute differences in position between repeat ABC CT scans of less than 4.1 mm, 3.3 mm, and 3.3 mm in the CC, AP, and ML directions, respectively. Analysis of 257 MV AP images from patients treated using ABC revealed an average intrafraction CC reproducibility (sigma) of diaphragm relative to vertebral bodies of 1.5 mm (range, 0.6-3.9 mm). The average interfraction CC reproducibility (sigma) was 3.4 mm (range, 1.5-7.9 mm), indicating less day-to-day reproducibility of diaphragm position relative to vertebral bodies. The average absolute intra and interfraction CC offset in diaphragm position relative to vertebral bodies was 1.7 and 3.7 mm, respectively, with 86% of intrafraction and 54% of interfraction absolute offsets 3.0 mm or less. CONCLUSIONS: Intrafraction reproducibility of liver position using ABC is good in the majority of screened patients. However, interfraction reproducibility is worse, suggesting a need for image guidance.

Adult↗

Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue.

PURPOSE: To investigate the feasibility of a biomechanical-based deformable image registration technique for the integration of multimodality imaging, image guided treatment, and response monitoring. METHODS AND MATERIALS: A multiorgan deformable image registration technique based on finite element modeling (FEM) and surface projection alignment of selected regions of interest with biomechanical material and interface models has been developed. FEM also provides an inherent method for direct tracking specified regions through treatment and follow-up. RESULTS: The technique was demonstrated on 5 liver cancer patients. Differences of up to 1 cm of motion were seen between the diaphragm and the tumor center of mass after deformable image registration of exhale and inhale CT scans. Spatial differences of 5 mm or more were observed for up to 86% of the surface of the defined tumor after deformable image registration of the computed tomography (CT) and magnetic resonance images. Up to 6.8 mm of motion was observed for the tumor after deformable image registration of the CT and cone-beam CT scan after rigid registration of the liver. Deformable registration of the CT to the follow-up CT allowed a more accurate assessment of tumor response. CONCLUSIONS: This biomechanical-based deformable image registration technique incorporates classification, targeting, and monitoring of tumor and normal tissue using one methodology.

Biomechanical Phenomena↗

Image-guided radiotherapy: rationale, benefits, and limitations.

Technological advances have greatly enhanced the specialty of radiation oncology by allowing more healthy tissue to be spared for the same or better tumour coverage. Developments in medical imaging are integral to radiation oncology, both for design of treatment plans and to localise the target for precise administration of radiation. At planning, definition of the tumour and healthy tissue is based on CT, augmented frequently with MRI and PET. At treatment, three-dimensional soft-tissue imaging can also be used to localise the target and tumour motion can be tracked with fluoroscopic imaging of radio-opaque markers implanted in or near the tumour. These developments allow changes in tumour position, size, and shape that take place during radiotherapy to be measured and accounted for to boost geometric accuracy and precision of radiation delivery. Image-guided treatment also enhances uniformity in doses administered in a population of patients, thus improving our ability to measure the effect of dosimetric and non-dosimetric factors on tumour and healthy tissue outcomes in clinical trials. Increased precision and accuracy of radiotherapy are expected to augment tumour control, reduce incidence and severity of toxic effects after radiotherapy, and facilitate development of more efficient shorter schedules than currently available.

Humans↗

Individualized image guided iso-NTCP based liver cancer SBRT.

A highly individualized stereotactic body radiotherapy (SBRT) strategy was developed to allow a wide spectrum of patients with liver cancer to be treated. This phase I/II study encompasses individualization of immobilization, radiation planning, PTV margin determination, image guidance strategy and prescription dose. Active breathing control breath hold is used to immobilize the liver when feasible. Image guidance strategies include orthogonal MV images and orthogonal kV fluoroscopy using the diaphragm for a surrogate for the liver, and kV cone beam CT using the liver or tumour for guidance. The prescription dose is individualized to maintain the same estimated risk of radiation-induced liver disease (RILD), based on a normal tissue complication probability (NTCP) model, with a maximum permitted dose of 60 Gy in 6 fractions. Since August 2003, 79 patients with hepatocellular carcinoma (33), intrahepatic cholangiocarcinoma (12) and liver metastases (34) were treated. The median tumour volume was 293 cm3 (2.9-3 088 cm3). The median prescribed dose was 36.6 Gy (24.0 Gy-57.0 Gy) in 6 fractions. The median effective liver volume irradiated was 45% (9-80%). Sixty percent of patients were treated with breath hold to immobilize their liver. Intra-fraction reproducibility (sigma) of the liver with repeat breath holds was excellent (1.5 mm); however inter-fraction reproducibility (sigma) was worse (3.4 mm). Image guidance reduced the residual systematic and random setup errors significantly.

Adult↗

Phase II trial of high-dose conformal radiation therapy with concurrent hepatic artery floxuridine for unresectable intrahepatic malignancies.

PURPOSE: A phase II trial was conducted to determine if high-dose radiation with concurrent hepatic arterial floxuridine would improve survival in patients with unresectable intrahepatic malignancies. PATIENTS AND METHODS: Three-dimensional conformal high-dose radiation therapy was delivered concurrently with hepatic arterial floxuridine in 128 patients. The radiation dose was based on a normal-tissue complication probability model and subjected the patient to an estimated maximum risk of radiation-induced liver disease of 10% to 15%. The study design provided more than 80% power to detect a two-fold increase in median survival compared with historical controls at a 5% significance level. RESULTS: The median radiation dose delivered was 60.75 Gy (1.5-Gy fractions bid). At a median follow-up time of 16 months (26 months in patients who were alive) the median survival was 15.8 months (95% CI, 12.6 to 18.3 months), significantly longer than in the historical control. The actuarial 3-year survival was 17%. The total dose was the only significant predictor of survival. Primary hepatobiliary tumors had a significantly greater tendency to remain confined to the liver than did colorectal cancer metastases. Overall toxicity was acceptable, with 27 patients (21%) and 11 patients (9%) developing grade 3 and 4 toxicity, respectively, and one treatment-related death. CONCLUSION: The results suggest that, compared with historical controls, high-dose focal liver irradiation with hepatic artery floxuridine prolongs survival in patients with unresectable chemotherapy-refractory metastatic colorectal cancer and primary hepatobiliary tumors. This provides a rationale for intensification of local therapy for unresectable hepatobiliary cancers and integration of this regimen with newer systemic therapy for patients with colorectal cancer.

Adult↗

Evaluating the influence of setup uncertainties on treatment planning for focal liver tumors.

PURPOSE: A mechanism has been developed to evaluate the influence of random setup variations on dose during treatment planning. The information available for studying these factors shifts from population-based models toward patient-specific data as treatment progresses and setup measurements for an individual patient become available. This study evaluates the influence of population as well as patient-specific setup distributions on treatment plans for focal liver tumors. METHODS AND MATERIALS: Eight patients with focal liver tumors were treated on a protocol that involved online setup measurement and adjustment, as well as ventilatory immobilization. Summary statistics from these three-dimensional conformal treatments yielded individual and population distributions of position at initial setup for each fraction. A convolution model for evaluation of the influence of random setup variation on calculated dose distributions has been previously described and investigated for application to focal liver radiotherapy by our department. Individual patient doses based on initial setup positions were calculated by convolving the calculated dose distribution with an anisotropic probability distribution function representing the individual patient's random variations. A separate convolution using population-averaged random variations was performed. Individual beam apertures were then adjusted to provide plans that ensured proper dose to the clinical target volume following convolution with population distributions, as well as individual patient position uncertainty models. RESULTS: Individual patient setup distributions for the course of treatment had random setup variations (sigma) that ranged from 2.5 to 5.7 mm (left-right), 2.1 to 8.3 mm (anterior-posterior), and 4.1 to 10.8 mm (cranial-caudal). The population random components were 4.2 mm (left-right), 4.1 mm (anterior-posterior), and 7.0 mm (cranial-caudal) at initial setup. The initial static planned dose distribution overestimated the volume of liver irradiated to high doses, because inclusion of setup uncertainties generally blurred the resulting doses, shifting the higher-dose region of normal liver dose-volume histograms to lower doses. Furthermore, the population-based dose convolution tended to predict a higher risk of radiation damage to the liver (based on an in-house parameterization of the Lyman normal tissue complication probability model) than the individual patient calculations. For an individual plan, application of different individual random variations yielded change in effective volume differences with a 3% range. Plan adjustment to account for random setup variations generally resulted in a lower change in effective volume than initial planning using a planning target volume followed by calculation of delivered dose based on random offsets. CONCLUSION: This study hints at the factors that most strongly influence planning of liver treatments taking into account geometric variations. Given a setup verification methodology that rapidly reduces systematic offsets, the importance of realistic incorporation of geometric variations as an initial step in treatment planning, as well as possible plan refinement, is demonstrated.

Feasibility Studies↗

Predictive factors of local-regional recurrences following parotid sparing intensity modulated or 3D conformal radiotherapy for head and neck cancer.

BACKGROUND AND PURPOSE: Predictive factors for local-regional (LR) failures after parotid-sparing, Intensity modulated (IMRT) or 3D conformal radiotherapy for head and neck (HN) cancers were assessed. PATIENTS AND METHODS: One hundred and fifty-eight patients with mostly stages III-IV HN squamous cell carcinoma underwent curative bilateral neck irradiation aimed at sparing the parotid glands. Patient, tumor, and treatment factors were analyzed as predictive factors for LR failure. RESULTS: Twenty-three patients had LR recurrence (19 in-field and four marginal). No differences were found in the doses delivered to the PTVs of patients with or without in-field recurrences. In univariate analysis, tumor site was highly predictive for LR failure in both postoperative and definitive RT patients. In postoperative RT patients, pathologic tumor size, margin status, extracapsular extension (ECE) and number of lymph node metastases, were also significantly predictive. Multivariate analysis showed tumor site (oropharynx vs. other sites) to be a significant predictor in all patients, and involved margins and number of involved lymph nodes in postoperative patients. CONCLUSIONS: Clinical rather than dosimetric factors predicted for LR failures in this series, and were similar to those reported following standard RT. These factors may aid in the selection of patients for studies of treatment intensification using IMRT.

Adult↗

Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control.

PURPOSE: A six-fraction, high-precision radiotherapy protocol for unresectable liver cancer has been developed in which active breathing control (ABC) is used to immobilize the liver and daily megavoltage (MV) imaging and repositioning is used to decrease geometric uncertainties. We report the accuracy of setup in the first 20 patients consecutively treated using this approach. METHODS AND MATERIALS: After setup using conventional skin marks and lasers, orthogonal MV images were acquired with the liver immobilized using ABC. The images were aligned to reference digitally reconstructed radiographs using the diaphragm for craniocaudal (CC) alignment and the vertebral bodies for anterior-posterior (AP) and mediolateral (ML) alignment. Adjustments were made for positioning errors >3 mm. Verification imaging was repeated after repositioning to assess for residual positioning error. Offline image matching was conducted to determine the setup accuracy using this approach compared with the initial setup error before repositioning. Real-time beam's-eye-view MV movies containing an air-diaphragm interface were also evaluated. RESULTS: A total of 405 images were evaluated from 20 patients. Repositioning occurred in 109 of 120 fractions because of offsets >3 mm. Three to eight beam angles, with up to four segments per field, were used for each isocenter. Breath holds of up to 27 s were used for imaging and treatment. The average time from the initial verification image to the last treatment beam was 21 min. Image guidance and repositioning reduced the population random setup errors (sigma) from 6.5 mm (CC), 4.2 mm (ML), and 4.7 mm (AP) to 2.5 mm (CC), 2.8 mm (ML), and 2.9 mm (AP). The average individual random setup errors (sigma) were reduced from 4.5 mm (CC), 3.2 mm (AP), and 2.5 mm (ML) to 2.2 mm (CC), 2.0 mm (AP), and 2.0 mm (ML). The standard deviation of the distribution of systematic deviations (Sigma) was also reduced from 5.1 mm (CC), 3.4 mm (ML), and 3.1 mm (AP) to 1.4 mm (CC), 2.0 mm (ML), and 1.9 mm (AP) with image guidance and repositioning. The average absolute systematic errors were reduced from 4.1 mm (CC), 2.4 mm (AP), and 3.1 (ML) to 1.1 mm (CC), 1.3 mm (AP), and 1.6 mm (ML). Analysis of 52 real-time beam's-eye-view MV movies revealed an average absolute CC offset in diaphragm position of 1.9 mm. CONCLUSION: Image guidance with orthogonal MV imaging and ABC for stereotactic body radiotherapy for liver cancer is feasible, improving setup accuracy compared with ABC without daily imaging and repositioning.

Carcinoma, Hepatocellular↗

Use of principal component analysis to evaluate the partial organ tolerance of normal tissues to radiation.

PURPOSE: To describe a novel method of analyzing partial volume effects of normal tissues to radiation. With this approach, principal component analysis (PCA) is used to efficiently describe the variance in cumulative dose-volume histogram (cDVH) morphology. The independent features of cDVHs that describe the largest variance are then investigated regarding complication risk. METHODS AND MATERIALS: Principal component analysis was used to describe the variance in the morphology of normal tissue cDVHs, irrespective of complication, by summarizing the largest source of variation within the first principal component (PC), the next largest in the second PC, and so on. Plots relating the most meaningful PCs were constructed. Ideally, cDVHs associated with a complication would yield PC values that could be easily segregated from cDVHs without a complication. Two data sets were evaluated with this approach: 90 parotid gland cDVHs (36 with complications) and 203 liver cDVHs (19 with complications). RESULTS: Ninety-four percent and 80% of the variation in cDVH morphology was described with two PCs for the parotid gland and the liver data sets, respectively. Plots of the first and second PC values on a Cartesian plane for both data sets revealed "clusters." For the parotid gland, one cluster contained PCs from parotid gland cDVHs with complications, and the other primarily contained PCs from cDVHs without complications. The first PC value, corresponding to a larger volume treated with 10-60 Gy (2 Gy per fraction), was more likely to be larger in parotid gland cDVHs associated with complications than those without complications. In the plots of PC values of liver cDVHs, whole liver radiation cDVHs were segregated from the other cDVHs. There was a trend for cDVHs with a higher first PC, corresponding to increased volume treated with approximately 10-40 Gy (1.5 Gy b.i.d.), to be associated with increased risk of complication. For partial liver radiation cDVHs there was a trend for cDVHs with a higher first PC, corresponding to an increased volume treated with 5-50 Gy, to be associated with a complication. For each data set, logistic regression modeling revealed that the first PC was significantly associated with a complication developing (p < 0.02). CONCLUSIONS: Principal component analysis can be used to summarize the variance in parallel normal tissue cDVHs, and it can help segregate cDVHs at high or low risk for complications.

Adult↗

Partial volume tolerance of the liver to radiation.

The use of conformal radiotherapy (RT) and the follow-up of patients for radiation liver toxicities has led to a quantitative understanding of partial liver RT tolerance. The most common toxicity is radiation-induced liver disease (RILD), a syndrome of anicteric ascites and hepatomegaly. Elevation of transaminases and reactivation of viral hepatitis have also been reported after liver RT. The Lyman normal tissue complication probability (NTCP) model and a local damage-organ injury NTCP model have been used to describe the partial tolerance of the liver to RT. The liver exhibits a large volume effect and a low threshold volume for RILD. The RT tolerance of the liver is reduced in patients with primary liver cancer versus metastases. Elevated transaminases are more common in the presence of poor liver function and hepatitis B infection. If the effective liver volume irradiated is less than 25%, very high RT doses may be delivered with little risk of liver toxicity. The mean liver doses associated with a 5% risk of classic RILD for primary and metastatic liver cancer are 28 Gy and 32 Gy, respectively, in 2 Gy per fraction.

Ascites↗