PubMed Health⌕ Search

Biomedical subjects

Laura L Morlock

Publications and source records attributed to Laura L Morlock.

6 recordsLinked to original sources

Toward learning from patient safety reporting systems.

PURPOSE: To evaluate the frequency and type of factors involved in incidents reported to a patient safety reporting system and answer specific questions to enhance the value of PSRS data to improve patient safety. MATERIALS AND METHODS: Prospective cohort study of incidents reported from adult and pediatric intensive care units (ICUs) in the United States to the web-based, voluntary, and anonymous Intensive Care Unit Safety Reporting System. Results from July 1, 2002, to June 30, 2004. Main outcome variables were incidents that could or did lead to patient harm. RESULTS: Analysis includes 2075 incidents from 23 ICUs. Median number of reports/ICU/month was 3; 5 hospitals submitted 58% of reports. Harm was reported in 42% of incidents with 18 deaths. Common event types: medication/therapeutics (42%) and incorrect/incomplete care delivery (20%); 48% of line/tube/drain incidents led to physical harm. Deficiencies in training/education contributed to 49% of incidents and teamwork issues 32%; 42% of incidents had 2 or more contributing factors. As the number of contributing factors per incident increased, so did risk of harm. CONCLUSIONS: The Intensive Care Unit Safety Reporting System provides a mechanism for multiple ICUs to identify hazards. Data trends show a correlation between multiple contributing factors and higher rates of harm. Further research is needed to help determine how to use PSRS data to improve patient safety.

Adult↗

Defining and measuring patient safety.

Despite the growing demand for improved safety in health care, debate remains regarding the magnitude of the problem and the degree to which harm is preventable. To a great extent, this debate stems from variation in the definition and methods for measuring safety, its "shadow" error, and the degree of preventability. This article reviews the definition of safety and error, discusses approaches to measuring safety, and provides a framework for investigating incidents that unveils how the systems under which care is delivered may contribute to adverse incidents.

Adult↗

A system factors analysis of "line, tube, and drain" incidents in the intensive care unit.

OBJECTIVE: To analyze the system factors related to "line, tube, and drain" (LTD) incidents in the intensive care unit (ICU). DESIGN: Voluntary, anonymous Web-based patient safety reporting system. SETTING: Eighteen ICUs in the United States. PATIENTS: Incidents reported by ICU staff members during a 12-month period ending June 2003. INTERVENTIONS: None. MEASUREMENTS: Characteristics of the incidents (defined as events that could/did cause harm), patients, and patient harm were described. Separate multivariable logistic regression analyses of contributing, limiting, and preventive system factors for LTD vs. non-LTD incidents were reported. MAIN RESULTS: Of the 114 reported LTD incidents, >60% were considered preventable. One patient death was attributed to an LTD incident. Of patients experiencing LTD incidents, 56% sustained physical injury, and 23% had an anticipated increased hospital stay. Factors contributing to LTD incidents included occurrence in the operating room (odds ratio [OR], 3.50; 95% confidence interval [CI], 1.25-9.83), occurrence on a holiday (OR, 3.65; 95% CI, 1.12-11.9), patient medical complexity (OR, 3.68; 95% CI, 2.28-5.92), and age of 1-9 yrs (OR, 7.95; 95% CI, 3.29-19.2). Factors related to team communication were less likely to limit LTD incidents (OR, 0.28; 95% CI, 0.11-0.68), while clinician knowledge and skills helped prevent LTD incidents (OR, 1.80; 95% CI, 1.09-2.97). CONCLUSIONS: Patients are harmed by preventable LTD incidents. Relative to non-LTD events, these incidents occur more frequently during holidays and in medically complex patients and children. Focusing on these contributing factors and clinician knowledge and skills is important for reducing and preventing these hazardous events.

Adolescent↗

Creating the web-based intensive care unit safety reporting system.

In an effort to improve patient safety, researchers at the Johns Hopkins University designed and implemented a comprehensive Web-based Intensive Care Unit Safety Reporting System (ICUSRS). The ICUSRS collects data about adverse events and near misses from all staff in the ICU. This report reflects data on 854 reports from 18 diverse ICUs across the United States. Reporting is voluntary, and data collected is confidential, with patient, provider, and reporter information deidentified. Preliminary data include system factors reported, degree of patient harm, reporting times, and evaluations of the system. Qualitative and quantitative data are reported back to the ICU site study teams and frontline staff through monthly reports, case discussions, and a quarterly newsletter.

Computer Communication Networks↗

A system factors analysis of airway events from the Intensive Care Unit Safety Reporting System (ICUSRS).

OBJECTIVE: To evaluate the contributing and limiting factors for airway events reported in the Intensive Care Unit Safety Reporting System (ICUSRS) developed in partnership with the Society of Critical Care Medicine. DESIGN: Analysis of system factors in airway vs. nonairway events reported to a voluntary, anonymous, Web-based patient safety reporting system (the ICUSRS). SETTING: Sixteen adult and two pediatric intensive care units (ICU) across the United States. PATIENTS: Incidents reported during the 12-month period ending June 30, 2003. INTERVENTIONS: None MEASUREMENTS: Descriptive characteristics of incidents (defined as events that could have, or did, cause harm), patients, and patient harm; separate multivariable logistic regression analyses of contributing and limiting factors for airway vs. nonairway events. MAIN RESULTS: There were 78 airway and 763 nonairway events reported. More than half of airway events were considered preventable. One patient death was attributed to an airway event. Physical injury, increased hospital length of stay, and family dissatisfaction occurred in at least 20% of airway events. Important factors contributing to reported airway events (odds ratio (OR), 95% confidence interval (CI)) included patients' medical condition (5.24, 3.07-8.95) and age <1 yr old (4.15, 1.79-9.59). Factors limiting the impact of airway events (OR, 95% CI) included adequate ICU staffing (3.60, 1.71-7.56) and use of skilled assistants (3.20, 1.62-6.32). CONCLUSIONS: Patients are harmed by unintended and preventable incidents involving airway management. Prevention efforts should focus on critically ill infants and patients with complex medical conditions. Managers should ensure appropriate ICU staffing to limit the impact of airway events when they occur.

Adolescent↗

Quality-based purchasing in health care.

Quality-based purchasing is a growing trend that seeks to improve healthcare quality through the purchaser-provider relationship. This article provides a unifying conceptual framework, presents examples of the purchaser-provider relationship in countries at different income levels, and identifies important supporting mechanisms for quality-based purchasing. As countries become wealthier, a higher proportion of healthcare spending is channeled through pooled arrangements, allowing for greater involvement of purchasers in promoting the quality of service provision. Global and line item budgets are the most common type of provider payment system in low and middle-income countries. In these countries, improving public hospital performance through contracting and incentives is a key issue. In middle and high-income countries, there are several documented examples of governments contracting to private or non-governmental health care providers, resulting in higher perceived quality of care and lower delivery costs. Encouraging quality through employer purchasing arrangements has been promoted in several countries, particularly the United States. Community-based financing schemes are an increasingly common form of health financing in parts of sub-Saharan Africa and Asia, but these schemes still cover less than 10% of national populations in countries in which they are active. To date, there is little evidence of their impact on healthcare quality. The availability of information--concerning healthcare service provision and outcomes--determines the options for establishing and monitoring contract provisions and promoting quality. Regardless of the context, quality-based purchasing depends critically on informa-tion--reporting, monitoring, and providing useful information to healthcare consumers. In many low and middle-income countries, the lack of availability of information is the principal constraint on measuring performance, a critical component of quality-based purchasing.

Africa South of the Sahara↗