PubMed Health⌕ Search

Biomedical subjects

Laurent Fauchier

Publications and source records attributed to Laurent Fauchier.

At least 19 recordsLinked to original sources

Different criteria of cardiac resynchronization therapy and their prognostic value for worsening heart failure or major arrhythmic events in patients with idiopathic dilated cardiomyopathy.

There are still controversies about pertinent criteria for cardiac resynchronization therapy (CRT) and prophylactic indications for biventricular cardioverter-defibrillators, particularly in idiopathic dilated cardiomyopathy (IDC). This study compared several criteria for resynchronization therapy in IDC among those of several completed trials. In 201 patients with IDC, the relative risk for (1) death from heart failure (HF) or heart transplantation and (2) sudden death or sustained ventricular tachyarrhythmia were calculated separately according to the inclusion criteria of the Multisite Stimulation in Cardiomyopathy (MUSTIC), InSync, Multicenter InSync Randomized Clinical Evaluation (MIRACLE), Pacing Therapies for Congestive Heart Failure (PATH-CHF), Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION), and CONTAK studies. The percentage of patients meeting the criteria ranged from 6% for those of MUSTIC to 23% for those of CONTAK. In a follow-up of 51 +/- 42 months, 28 patients died (15 from progressive HF, 13 from sudden death), 20 underwent heart transplantation, and 12 had sustained ventricular tachyarrhythmia. Relative risks of worsening HF ranged from 3.14 (95% confidence interval [CI] 1.41 to 6.99, p = 0.005) for the MIRACLE criteria to 4.63 (95% CI 1.76 to 12.2, p = 0.0019) for the MUSTIC criteria. Only the CONTAK criteria were significantly associated with a risk for major arrhythmic events (2.65, 95% CI 1.19 to 5.95, p = 0.018). Arrhythmic events constituted 16% of all cardiac events for the MUSTIC patients, 11% for InSync patients, 31% for PATH-CHF patients, 36% for MIRACLE patients, 38% for COMPANION patients, and 42% for CONTAK patients. In conclusion, in IDC, the less restrictive criteria for CRT were associated with the greatest risk for arrhythmic events. In contrast, patients with the MUSTIC criteria for CRT mainly had a risk for worsening HF and may not benefit from biventricular cardioverter-defibrillators.

Adult↗

QT dispersion in nonischemic dilated cardiomyopathy. A long-term evaluation.

BACKGROUND: In idiopathic dilated cardiomyopathy (IDC), the predictive value of QT dispersion is still under debate. AIMS: This study assessed the role of QT dispersion for the long-term risk of cardiac death and of major arrhythmic events in IDC. METHODS AND RESULTS: In 162 patients with IDC (age 52+/-12 years), the QT interval on a 12-lead ECG was measured manually. QT dispersion was evaluated with QT range and QT standard deviation, for both QT and QTc (Bazett formula). With a follow-up of 53+/-41 months, QT dispersion was not a predictor of cardiac death in univariate or in multivariate analysis, and was of similar value for patients with or without bundle branch block. Using multivariate analysis, increased pulmonary capillary wedge pressure (p=0.003), decreased heart rate variability (Standard deviation of all NN intervals, p=0.01) and non-sustained ventricular tachycardia (NSVT) (p=0.03) were predictors of cardiac death. Sudden death and/or major arrhythmic events were independently predicted by NSVT (p=0.005), decreased heart rate variability (p=0.01) and late ventricular potentials on signal averaged ECG (p=0.02). CONCLUSION: This study confirms the poor prognostic value of QT dispersion in patients with IDC. Other methods to assess repolarization abnormalities need to be evaluated in such patients.

Adult↗

CO inhalation at dose corresponding to tobacco smoke worsens cardiac remodeling after experimental myocardial infarction in rats.

We hypothesized that inhalation of carbon monoxide (CO) (500 ppm), similar to that in tobacco smoke, disturbs the cardiovascular adaptation after myocardial infarction by increasing remodeling. Four groups of rats were assessed. Two groups had myocardial infarction induced by the ligation of the left coronary artery: the first group was exposed to air (infarcted air group, n = 12), and the second was exposed to CO (infarcted CO group, n = 11). They were compared to two sham-operated groups, a control air group (n = 10), and a control CO group (n = 7) exposed (3 weeks) to CO. Aerobic endurance capacity was assessed in both the infarct CO and infarct air group (endurance capacity = 0.043 +/- 0.006 m.min(-1).g(-1) vs. 0.042 +/- 0.005 m.min(-1).g(-1), not significant). In the infarcted CO group compared to the infarcted air group, the dilatation of the left ventricle observed 3 weeks after infarction was increased, (left ventricular diastolic (LVD) diameter (D) = 9 +/- 0.4 vs. 7 +/- 0.4 mm, p < 0.05; left ventricular systolic (LVS) diameter (D) = 6 +/- 0.6 vs. 4.1 +/- 0.4, p < 0.05), and the diastolic posterior wall thickness was augmented (posterior wall diastolic thickness = 1.7 +/- 0.1 vs. 1.3 +/- 0.1 mm, p < 0.05). Hemodynamic pressure measurements in both ventricles and pulmonary artery showed elevated diastolic pressure after CO exposure compared to air exposure (LVD pressure = 32 +/- 1.6 vs. 19 +/- 2.3 mm Hg, p < 0.05; right ventricular diastolic pressure = 16 +/- 1.6 vs. 8.6 +/- 1.6 mm Hg, p < 0.05; pulmonary arterial pressure in diastole (PAD) = 27 +/- 1.6 vs. 20 +/- 2.3 mm Hg, p < 0.05). In the infarcted CO group, the infarct size increased. Echocardiography and histology showed hypertrophy of the contralateral wall similar to that observed in the noninfarcted control CO group. In conclusion, chronic CO inhalation worsens heart failure in rats with myocardial infarction by an increase in the infarct size and hypertrophy remodeling.

Administration, Inhalation↗

Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients.

Home monitoring (HM) of cardioverter defibrillators (ICD) with its automated wireless remote data access, may decrease the rate of patient visits. This study examined the potential cost savings for the long-term care of ICD assisted by HM. A French database including 502 patients from 6 university hospitals was used. Costs of conventional follow-up (FU) of ICD were calculated without, and compared with the expected cost of FU with HM. Calculations included number of visits, including physician's fees, electrocardiograms, and specific ICD surveillance, and transportation costs. The mean distance between home and institutions performing follow-ups was 69 +/- 57 km. For each visit, a mean overall cost of 215 dollars was calculated, including 121 dollars for transportation and 94 dollars for medical services. HM may obviate up to 2 visits per year. Over the 5 years of expected life of the device, the decrease in costs for FU visits was estimated at 2,149 dollars. With an additional cost of 1,200 dollars for the HM system, saving began after a mean FU of 33.5 months. The time to onset of cost saving by HM ranged between 17.4 months for patients living >150 km from the medical facility to 52.2 months for those living <50 km away. It is concluded that the HM may considerably reduce the overall costs of ICD FU by saving on transportation cost, particularly when the distance between home and medical facility is >100 km.

Cost Savings↗

Direct implication of carbon monoxide in the development of heart failure in rats with cardiac hypertrophy subjected to air pollution.

Pollution is known to particularly affect patients with respiratory insufficiency and right ventricle abnormalities. We therefore hypothesized that carbon monoxide (CO) at low dose could be involved in cardiovascular disorders in patients with chronic hypoxic pulmonary hypertension secondary to chronic hypoxia. Ten-week-old male and female healthy Dark Agouti rats were randomly divided into two series--untrained (U) and trained (T)--of four groups of 18 animals each. Both U and T series were continuously exposed to ambient air (U(AIR), and T(AIR); n = 16) or air plus 50 ppm CO (U(AIR+CO) and T(AIR+CO); n = 18). Similarly, rats initially subjected to right ventricle hypertrophy secondary to chronic hypoxia (H) were continuously exposed to ambient air (TH(AIR), and UH(AIR); n = 18) or air plus 50 ppm CO (UH(AIR+CO), and TH(AIR+CO); n = 18). Doppler-echocardiography and hemodynamic studies performed at rest both indi-cated that CO had no significant effect on cardiac morphology or functions in control rats (U(AIR+CO) vs U(AIR)). In contrast, cardiac dilation and large decreases in left ventricular ejection fraction, mitral early diastolic rapid inflow (E) deceleration, E/atrial contraction filling (A) ratio, +dP/dt, and -dP/dt were found in TH(AIR+CO) compared with TH(AIR). After exposure, heart rate variability was unaffected in U(AIR+CO), whereas total power spectra were markedly decreased and low frequency/high frequency power ratio was increased in TH(AIR+CO) rats. CO pollution could be directly involved in cardiac disorders of patients with pre-existent hypertrophic cardiomyopathies.

Air Pollutants, Occupational↗

Segmental wall motion abnormalities in idiopathic dilated cardiomyopathy and their effect on prognosis.

There is considerable variability in segmental wall motion abnormalities and in the prognosis of idiopathic dilated cardiomyopathy (IDC). Radionuclide ventriculography with Fourier analysis was performed in 107 patients with angiographically proved IDC. Amplitude analysis located the wall motion abnormalities. Using phase analysis in the left and right ventricles, the interventricular delay between the mean phase of the right and left ventricles was used to assess interventricular dyssynchrony and SDs of the mean phase in each ventricle was used to assess intraventricular dyssynchrony. Hypokinesis was global in 56 patients (52%) and localized in the anteroseptal wall in 34 (32%), the inferior wall in 12 (11%), the anteroseptal and inferior walls in 2 (2%), and the lateral wall in 3 (3%). Patients with localized wall motion abnormalities had larger left ventricular (LV) end-diastolic diameters (70 +/- 9 vs 66 +/- 8 mm, p = 0.009) and lower LV ejection fractions (25 +/- 9% vs 31 +/- 12%, p = 0.005). Intraventricular dyssynchrony was lower in patients with global hypokinesis (SD of LV mean phase 67 +/- 35 vs 48 +/- 22 ms, p = 0.002). With a follow-up of 27 +/- 23 months, increased SD of the LV phase (p = 0.005), decreased right ventricular ejection fraction (p = 0.006), decreased LV ejection fraction (p = 0.04), and localized wall motion abnormality (p = 0.009) were independent predictors of cardiac death or worsening heart failure leading to heart transplantation. Thus, segmental wall motion abnormalities are frequent in IDC and are associated with severe systolic dysfunction and a worse prognosis.

Cardiomyopathy, Dilated↗

Heart rate variability in severe right or left heart failure: the role of pulmonary hypertension and resistances.

BACKGROUND: The decrease in heart rate variability (HRV) might be related to the hemodynamic status in heart failure. However, HRV in patients with severe isolated right heart failure has not been extensively studied. AIMS: This study compared HRV in patients with congestive heart failure (CHF) and in patients with isolated right heart failure. METHODS: Time and frequency domain analysis of HRV on 24-h ECG recording was assessed in 15 healthy subjects and in two groups of patients with severe heart failure awaiting heart or heart/lung transplantation. These were 15 patients with CHF due to idiopathic dilated cardiomyopathy (IDC) and 10 patients with isolated right heart failure due to primary pulmonary hypertension (PPH). RESULTS: Measurement of HRV were significantly decreased in both groups of patients compared with the control group. Patients with IDC had higher pulmonary capillary wedge pressure than patients with PPH (P=0.04) but lower pulmonary artery pressure and lower pulmonary vascular resistance (PVR) (P<0.0001). However, all the measurements of HRV were significantly lower in patients with IDC than in patients with PPH (range 22-77%, P<0.05 to P<0.01). None of the HRV measurements correlated with filling pressure measurements. CONCLUSIONS: The increase in pulmonary vascular resistance in heart failure is not the main causal factor behind a decrease in HRV.

Adult↗

Reliability of QRS duration and morphology on surface electrocardiogram to identify ventricular dyssynchrony in patients with idiopathic dilated cardiomyopathy.

Using Fourier phase analysis of equilibrium radionuclide angiography in both ventricles, inter- and intraventricular delays were correlated with QRS morphology and duration in 103 patients with idiopathic dilated cardiomyopathy. We found that left bundle branch block on the left axis may reflect a high intra-left ventricular dyssynchrony. A precise evaluation of the dyssynchrony appears useful because a high proportion of patients with incomplete bundle branch block, left anterior hemiblock, or "normal" QRS exhibit a marked intra-LV dyssynchrony and may respond to cardiac resynchronization therapy.

Bundle-Branch Block↗