Laurent Giovangrandi

Publications and source records attributed to Laurent Giovangrandi.

3 recordsLinked to original sources

Robust neural-network-based classification of premature ventricular contractions using wavelet transform and timing interval features.

Automatic electrocardiogram (ECG) beat classification is essential to timely diagnosis of dangerous heart conditions. Specifically, accurate detection of premature ventricular contractions (PVCs) is imperative to prepare for the possible onset of life-threatening arrhythmias. Although many groups have developed highly accurate algorithms for detecting PVC beats, results have generally been limited to relatively small data sets. Additionally, many of the highest classification accuracies (> 90%) have been achieved in experiments where training and testing sets overlapped significantly. Expanding the overall data set greatly reduces overall accuracy due to significant variation in ECG morphology among different patients. As a result, we believe that morphological information must be coupled with timing information, which is more constant among patients, in order to achieve high classification accuracy for larger data sets. With this approach, we combined wavelet-transformed ECG waves with timing information as our feature set for classification. We used select waveforms of 18 files of the MIT/BIH arrhythmia database, which provides an annotated collection of normal and arrhythmic beats, for training our neural-network classifier. We then tested the classifier on these 18 training files as well as 22 other files from the database. The accuracy was 95.16% over 93,281 beats from all 40 files, and 96.82% over the 22 files outside the training set in differentiating normal, PVC, and other beats.

Algorithms↗

Sensitivity of cell-based biosensors to environmental variables.

Electrically active living cells cultured on extracellular electrode arrays are utilized to detect biologically active agents. Because cells are highly sensitive to environmental conditions, environmental fluctuations can elicit cellular responses that contribute to the noise in a cell-based biosensor system. Therefore, the characterization and control of environmental factors such as temperature, pH, and osmolarity is critical in such a system. The cell-based biosensor platform described here utilizes the measurement of action potentials from cardiac cells cultured on electrode arrays. A recirculating fluid flow system is presented for use in dose-response experiments that regulates temperature within +/-0.2 degrees C, pH to within +/-0.05 units, and allows no significant change in osmolarity. Using this system, the relationship between the sensor output parameters and environmental variation was quantified. Under typical experimental conditions, beat rate varied approximately 10% per degree change in temperature or per 0.1 unit change in pH. Similar relationships were measured for action potential amplitude, duration, and conduction velocity. For the specific flow system used in this work, the measured environmental sensitivity resulted in an overall beat rate variation of +/-4.7% and an overall amplitude variation of +/-3.3%. The magnitude of the noise due to environmental sensitivity has a large impact on the detection capability of the cell-based system. The significant responses to temperature, pH, and osmolarity have important implications for the use of living cells in detection systems and should be considered in the design and evaluation of such systems.

Biosensing Techniques↗

A closed-loop electrical stimulation system for cardiac cell cultures.

An integrated electrical stimulation and recording system was designed for closed-loop control and analysis of cardiac cultures on planar microelectrode arrays. Stimulated action potentials from HL-1 clonal myocyte cultures were digitized, stimulation artifacts were removed using nulling and filtering methods, and analysis was performed to determine stimulation efficacy in real time. Results of this analysis were used to determine future stimulation waveform parameters such as polarity, amplitude, pulse duration, and rate or pattern. Algorithms were designed utilizing real-time analysis and control to maintain a desired electrophysiological response of the culture, such as an arbitrary capture fraction value. This paper presents the hardware and software design of the stimulus pulse circuitry, artifact extraction, analysis, and control components of the system. Applications of this technology include the study of cardiac cell physiology, improving the speed and accuracy of traditional open-loop stimulation protocols, pharmacological screening, and improving the performance of biosensors based on sensing electrical activity in cardiac cultures.

Action Potentials↗