PubMed Health⌕ Search

Biomedical subjects

Lauri Toivonen

Publications and source records attributed to Lauri Toivonen.

50 records · Page 3Linked to original sources

Baseline reconstruction for localization of rapid ventricular tachycardia from body surface potential maps.

Determination of an accurate electrocardiographic (ECG) baseline is generally needed for localization of ventricular arrhythmias with body surface potential mapping (BSPM). We suggest a novel signal processing method for ECG baseline reconstruction during monomorphic ventricular tachycardias (VT). The method is based on an assumption that VT consists of similar ventricular extrasystolic beats with overlapping depolarization and repolarization. The sequential reconstruction algorithm utilizes information of small variations in the heart rate and yields a non-overlapping QRST-signal, provided that the measurement set-up has a high enough temporal resolution to avoid distortions due to sampling differences and misalignment of individual beats. The reconstructed QRST-signal is utilized to subtract overlapping T-waves from the QRS complexes during VT. The use of the method is demonstrated with clinically measured BSPM data.

Body Surface Area↗

Spatiotemporal characterization of paced cardiac activation with body surface potential mapping and self-organizing maps.

In this study self-organizing maps (SOM) were utilized for spatiotemporal analysis and classification of body surface potential mapping (BSPM) data. Altogether 86 cardiac depolarization (QRS) sequences paced by a catheter in 18 patients were included. Spatial BSPM distributions at every 5 ms over the QRS complex were first presented to an untrained SOM. The learning process of the SOM units organized the maps in such a way that similar BSPMs are represented in particular areas of the SOM network. Thereafter, time trajectories and distance maps were created on the trained SOM from sequential maps in a selected paced QRS. The trajectories and distance maps can be applied as such for the localization of abnormal ventricular activation, as well as quantitative input for statistical classification. The results indicate that the method has potential for locating endocardial sites of abnormal ventricular activation, despite the patient material being too limited to provide a reliable statistical evaluation of the source localization accuracy.

Algorithms↗

Ambulatory electrocardiographic evidence of transmural dispersion of repolarization in patients with long-QT syndrome type 1 and 2.

BACKGROUND: Transmural dispersion of repolarization (TDR) may be related to the genesis of torsade de pointes (TdP) in patients with the long-QT (LQT) syndrome. Experimentally, LQT2 models show increased TDR compared with LQT1, and beta-adrenergic stimulation increases TDR in both models. Clinically, LQT1 patients experience symptoms at elevated heart rates, but LQT2 patients do so at lower rates. The interval from T-wave peak to T-wave end (TPE interval) is the clinical counterpart of TDR. We explored the relationship of TPE interval to heart rate and to the presence of symptoms in patients with LQT1 and LQT2. METHODS AND RESULTS: We reviewed Holter recordings from 90 genotyped subjects, 31 with LQT1, 28 with LQT2, and 31 from unaffected family members, to record TPE intervals by use of an automated computerized program. The median TPE interval was greater in LQT2 (112+/-5 ms) than LQT1 (91+/-2 ms) or unaffected (86+/-3 ms) patients (P<0.001 for all group comparisons), and the maximal TPE values differed as well. LQT1 patients showed abrupt increases in TPE values at RR intervals from 600 to 900 ms, but LQT2 patients did so at RR intervals from 600 to 1400 ms (longest RR studied). Asymptomatic and symptomatic patients showed similar TDRs. CONCLUSIONS: TDR is greater in LQT2 than in LQT1 patients. LQT1 patients showed a capacity to increase TDR at elevated heart rates, but LQT2 patients did so at a much wider rate range. The magnitude of TDR is not related to a history of TdP.

Adult↗

Differentiation between LQT1 and LQT2 patients and unaffected subjects using 24-hour electrocardiographic recordings.

This study assesses the use of 24-hour ambulatory electrocardiographic recordings in distinguishing patients with long-QT1 syndrome (LQT1) from those with LQT2, and for distinguishing affected from unaffected patients. The diagnoses of the congenital LQT syndrome and its most common types LQT1 and LQT2 are made difficult because of the limitations of the electrocardiogram as a diagnostic tool. With an automated computerized program, Holter recordings from 15 LQT1 and 15 LQT2 patients and 43 healthy subjects (training set) were reviewed to select the best criteria using QT duration and rate dependence as well as the difference between QT end and QT apex to separate the 3 groups. Fixed criteria were then applied in blinded fashion to separate a different group of 32 genotyped patients and 16 unaffected subjects (test set). In the training set, the RR interval (100 ms), a slope value for median QT/RR curves of -0.016 separated 25 of 30 (83%) and a minimal QT end - QT apex value of 80 ms, separated 26 of 30 (87%) LQT1 patients from LQT2 patients. When all selected criteria were applied to differentiate LQT1 from LQT2 versus unaffected genotypes in the test set, 38 of 48 cases (79%) were correctly identified, whereas using the electrocardiogram alone, 60% of patients were correctly classified into 3 genotypes (p = 0.03). Combining measures for QT duration, rate dependence, and QT end - QT apex interval, derived from Holter recordings, complements the clinical differentiation between LQT1 versus LQT2 patients and between affected and unaffected persons for genotype screening purposes.

Adolescent↗

Ethnic differences in electrocardiographic criteria for left ventricular hypertrophy: the LIFE study. Losartan Intervention For Endpoint.

BACKGROUND: African Americans have greater precordial QRS voltages than whites, with concomitant higher prevalences of electrocardiographic (ECG) left ventricular hypertrophy (LVH) and lower specificity of ECG LVH criteria for the identification of anatomic hypertrophy. However, the high mortality associated with LVH in African American patients makes more accurate ECG detection of LVH in these patients a clinical priority. METHODS: Electrocardiograms and echocardiograms were obtained at study baseline in 120 African American and 751 white hypertensive patients enrolled in the Losartan Intervention For Endpoint (LIFE) echocardiographic substudy. The ECG LVH was determined using Sokolow-Lyon, 12-lead sum, and Cornell voltage criteria. Echocardiographic LVH was defined by LV mass indexed to height(2.7) >46.7 g/m(2.7) in women and >49.1 g/m(2.7) in men. RESULTS: After adjusting for ethnic differences in LV mass, body mass index, sex, and prevalence of diabetes, mean Sokolow-Lyon and 12-lead sum of voltage were significantly higher, but Cornell voltage was lower, in African Americans than in whites. As a consequence of these differences, when identical partition values were used in both ethnic groups, Sokolow-Lyon and 12-lead voltage criteria had lower specificity in African Americans than whites (44% v 69%, P = .007 and 44% v 59%, P = .10) but had greater sensitivity in African Americans (51% v 27%, P < .001 and 62% v 45%, P = .003). In contrast, Cornell voltage specificity was higher (78% v 62%, P = .09) but sensitivity was slightly lower (49% v 57%, P = 0.16) in African Americans. However, when overall test performance was compared using receiver operating curve analyses that were independent of partition value selection, ethnic differences in test performance disappeared, with no differences in accuracy of any of the ECG voltage criteria for the identification of LVH between African American and white hypertensive individuals. CONCLUSIONS: When standard, non-ethnicity-specific thresholds for the identification of LVH are used, Sokolow-Lyon and 12-lead voltage overestimate and Cornell voltage underestimates the presence and severity of LVH in African American relative to white individuals. However, these apparent ethnic differences in test performance disappear when ethnic differences in the distribution of ECG LVH criteria are taken into account. These findings demonstrate that ethnicity-specific ECG criteria can equalize detection of anatomic LVH in African American and white patients.

Aged↗

Detection of rapid changes in ventricular refractoriness in human studies.

Conventional determination of the ventricular effective refractory period (VERP) is unsuitable for detection of rapid fluctuations in the effective refractory period (ERP). A programmed stimulation system was developed that adapts continuous atrioventricular sequential pacing, incremental extrastimulus interval (S1S2) scanning, and automatic detection of extrastimulus capture which is followed by shortening of S1S2 to execute repeated scanning. The accuracy of ERP determination was tested using variable incremental (2 and 4 ms) and decremental (4-16 ms) steps of the S1S2 interval. Based on a mean of 82 determinations in eight patients, the average VERP values stayed at 249.8-251.0 ms except during the highest capture frequency. Standard deviation of ERP values ranged from 1.1 to 2.5 ms on average at the tested incremental and decremental steps. One determination was accomplished within 7.8-15.6 seconds on average. The ability to track changes in ERP was tested by changing the drive cycle length. Time constants for the adaptation rate of VERP and ventricular monophasic action potential duration at a 90% level of repolarization were determined from each test, and were similar, 51 +/- 8 seconds (mean +/- SEM) for ERP and 51 +/- 6 seconds for the action potential duration. Thus, the developed method provides accurate ERP measurements during rapid variation in ventricular refractoriness. It allows studying the recovery of excitability and the action potential duration simultaneously, and would be valuable particularly in pathological conditions and pharmacologic interventions where these electrophysiological variables become dissociated.

Action Potentials↗

Relation of magnetocardiographic arrhythmia risk parameters to delayed ventricular conduction in postinfarction ventricular tachycardia.

Time-domain late field and intra-QRS fragmentation parameters in magnetocardiography (MCG) identify patients prone to VT after myocardial infarction. This study investigated if they are related to slow ventricular conduction and affected by arrhythmia surgery. Twenty-two patients with old myocardial infarction undergoing map-guided subendocardial resection to treat sustained VT were included. Bipolar electrograms were recorded during operation using an epicardial jacket and endocardial balloon electrode array. The time from the QRS onset to the end of local ventricular excitation in each electrogram was measured during sinus rhythm. Multi-channel MCG was recorded before and after operation and filtered QRS duration (QRSd), root mean square amplitude of the magnetic field strength during the last 40 ms of the QRS complex (RMS40), duration of the low amplitude signal < 300 fT (LAS300), fragmentation index M (M), and fragmentation score S (S) were determined. All patients had one or two VT foci localized and resected. MCG parameters correlated with time to the latest end of ventricular excitation; r = 0.45 for QRSd (P = 0.035), r = 0.64 for M (P = 0.001), and r = 0.73 for S (P < 0.001). The correlations were even better in patients with anterior infarction (e.g., r = 0.87 for QRSd, P < 0.001; r = 0.91 for M, P < 0.001). The operation reduced the abnormalities in MCG parameters and 20 of the 21 patients tested postoperatively became noninducible. MCG parameters indicating postinfarction arrhythmia propensity are related to delayed ventricular conduction. Abolition of the arrhythmia substrate reverses the abnormality of these parameters.

Electrocardiography↗

Features of ST segment and T-wave in exercise-induced myocardial ischemia evaluated with multichannel magnetocardiography.

BACKGROUND AND AIM: Magnetocardiography (MCG) is a novel, non-contact mapping technique to record cardiac magnetic field. We evaluated MCG criteria for myocardial ischemia in stress testing. METHODS: Multichannel MCG over frontal chest was performed in 44 patients with coronary artery disease (CAD) and 26 healthy controls during supine bicycle exercise test. Of the 44 patients 16 had anterior, 15 posterior, and 13 inferior ischemia documented by coronary angiography and exercise thallium scintigraphy. ST amplitude, ST slope, T-wave amplitude, and ST-T integral were measured. The optimal sites for detecting the ischemia-induced changes on MCG were sought. The orientation of the magnetic field was also determined. RESULTS: The optimal sites for the decrease of ST slope, ST amplitude, T-wave amplitude, and ST-T integral were over the abdomen. The reciprocal increase of these parameters was found over the left parasternal area. The optimal sites were approximately the same for all patient groups. In single-vessel disease patients without previous myocardial infarction (MI), ST slope increase and ST elevation performed the best (area under the receiver operating characteristic curve 92% and 90%, respectively). In post-MI patients with triple-vessel disease the decrease of T-wave amplitude and ST slope performed the best (area under curve 91%, for both). The magnetic field orientation at ST segment performed equally well as the other ST parameters. In stepwise logistic regression analysis, by use of the presence of CAD as the dependent parameter, ST slope increase and ST peak gradient orientation entered the model. CONCLUSIONS: Various ST segment and T-wave parameters detect ischemia in MCG. ST amplitude performs especially well in non-MI patients with less severe CAD. In advanced CAD late development of T-wave amplitude might be more sensitive to ischemia than ST amplitude.

Aged↗

Magnetocardiographic indices of left ventricular hypertrophy.

OBJECTIVE: We tested the hypothesis that multichannel magnetocardiographic (MCG) mapping can detect and quantify the degree of left ventricular hypertrophy (LVH). DESIGN: A cross-sectional study. SETTING: Helsinki University Central Hospital, a tertiary referral center. PARTICIPANTS: Forty-two patients with pressure overload induced LVH by gender-specific echocardiographic criteria (LVH group), and 12 healthy middle-aged controls. MAIN OUTCOME MEASURES: MCG QRS-T area integrals and QRS-T angle in magnetic field maps in relation to echocardiographic LVH as well as left ventricular (LV) mass and structure. Conventional 12-lead electrocardiographic (ECG) LVH indices (Sokolow-Lyon voltage, Cornell voltage, Cornell voltage duration product) were assessed for comparison. RESULTS: MCG QRS- and T-wave integrals provided complementary information of echocardiographic LV mass. Their combination, the QRS-T integral, and the QRS-T angle were increased in patients with LVH and, in those patients, correlated significantly with LV mass indexed to body surface area (r = 0.455;P = 0.002 and r= 0.379; P= 0.013, respectively). A QRS-T integral 16000 fT.s had identical sensitivity of 62% at 92% specificity as the gender-adjusted Cornell voltage duration product of 240 micro V.s for the detection of LVH. CONCLUSIONS: The MCG method can detect patients with LVH and also quantify the degree of LVH in patients with increased LV mass.

Aged↗

Late QRS activity in signal-averaged magnetocardiography, body surface potential mapping, and orthogonal ECG in postinfarction ventricular tachycardia patients.

BACKGROUND: Delayed electrical activity necessary for re-entrant ventricular tachycardia (VT) is detectable noninvasively with high resolution techniques. We compared high resolution signal-averaged analysis of magnetocardiography (MCG), body surface potential mapping (BSPM), and orthogonal three-lead ECG (SA-ECG) in the identification of patients prone to VT after myocardial infarction (MI). METHODS: Patients with remote myocardial infarction and cardiac dysfunction were studied, 22 with (VT group) and 22 without VT (control group). MCG with seven channels and BSPM with 63 and SA-ECG with three orthogonal leads were registered. After signal-averaging and highpass filtering, three time domain analysis (TDA) parameters describing late electrical activity were computed: QRS duration (QRSd), root mean square amplitude (RMS) of the last 40 ms of QRS, and the duration of the low-amplitude QRS end (LAS). RESULTS: All parameters by each method were significantly different between the patients' groups. For example, LAS parameter in MCG was 59 (SD 22) ms in the VT group vs. 37 (SD 13) ms in controls (P < 0.001), 77 (SD 22) ms vs. 56 (SD 19) ms in BSPM (P = 0.002), and 60 (SD 24) ms vs. 39 (SD 22) ms in SA-ECG (P = 0.005). The combination of LAS parameter in MCG and SA-ECG resulted in improved performance in comparison to any single parameter with 95% sensitivity and 68% specificity. CONCLUSIONS: All three high resolution methods identified VT propensity among post-MI patients with cardiac dysfunction and between-method differences were small. Information in MCG and SA-ECG may be complementary and their combination could be of value in postinfarction arrhythmia risk assessment.

Aged↗