Comparison of the Paul ion trap to the linear ion trap for use in global proteomics.

A critical evaluation of the performance of a 2-D linear ion trap (IT) instrument to two 3-D quadrupole IT instruments with emphasis on identification of rat serum proteins by bottom-up LC-MS/MS is presented. The speed and sensitivity of each of the instruments were investigated, and the effects that each of these have on the bottom-up proteomics identification approach are discussed.

Animals↗

Statistical design of experiments as a tool in mass spectrometry.

This Tutorial is an introduction to statistical design of experiments (DOE) with focus on demonstration of how DOE can be useful to the mass spectrometrist. In contrast with the commonly used one factor at a time approach, DOE methods address the issue of interaction of variables and are generally more efficient. The complex problem of optimizing data-dependent acquisition parameters in a bottom-up proteomics LC-MS/MS analysis is used as an example of the power of the technique. Using DOE, a new data-dependent method was developed that improved the quantity of confidently identified peptides from rat serum.

Animals↗

Meerwein reaction of phosphonium ions with epoxides and thioepoxides in the gas phase.

Phosphonium ions are shown to undergo a gas-phase Meerwein reaction in which epoxides (or thioepoxides) undergo three-to-five-membered ring expansion to yield dioxaphospholanium (or oxathiophospholanium) ion products. When the association reaction is followed by collision-induced dissociation (CID), the oxirane (or thiirane) is eliminated, making this ion molecule reaction/CID sequence a good method of net oxygen-by-sulfur replacement in the phosphonium ions. This replacement results in a characteristic mass shift of 16 units and provides evidence for the cyclic nature of the gas-phase Meerwein product ions, while improving selectivity for phosphonium ion detection. This reaction sequence also constitutes a gas-phase route to convert phosphonium ions into their sulfur analogs. Phosphonium and related ions are important targets since they are commonly and readily formed in mass spectrometric analysis upon dissociative electron ionization of organophosphorous esters. The Meerwein reaction should provide a new and very useful method of recognizing compounds that yield these ions, which includes a number of chemical warfare agents. The Meerwein reaction proceeds by phosphonium ion addition to the sulfur or oxygen center, followed by intramolecular nucleophilic attack with ring expansion to yield the 1,3,2-dioxaphospholanium or 1,3,2-oxathiophospholanium ion. Product ion structures were investigated by CID tandem mass spectrometry (MS(2)) experiments and corroborated by DFT/HF calculations.

Journal Article↗

Trace analysis of organics in air by corona discharge atmospheric pressure ionization using an electrospray ionization interface.

A corona discharge ion source operating at atmospheric pressure in the point-to-plane configuration was constructed by reconfiguring the ion source of a commercial electrospray ionization (ESI) quadrupole mass spectrometer. This new source allows direct air analysis without modification to the mass spectrometer. Detection and quantitation of semi-volatile compounds in air is demonstrated. The analytical performance of the system was established using the chemical warfare agent simulants methyl salicylate and dimethyl methylphosphonate. Limits of detection are 60 pptr in the negative-ion mode and 800 pptr in the positive-ion mode for methyl salicylate and 800 pptr in the negative-ion mode and 3.6 ppb in the positive-ion mode for dimethyl methylphosphonate. A linear response was observed from 60 pptr to 8 ppb for methyl salicylate in air in the negative-ionization mode. Cluster ion formation versus production of analyte ions was investigated and it was found that dry air or an elevated capillary interface temperature (130 degrees C) was needed to avoid extensive clustering, mostly of water. Reagent gases are not needed as proton sources, as is usually the case for atmospheric pressure chemical ionization, and this, together with the simplicity, sensitivity and speed of the technique, makes it promising for miniaturization and future field studies.

Journal Article↗

Ion/molecule reactions performed in a miniature cylindrical ion trap mass spectrometer.

A recently constructed miniature mass spectrometer, based on a cylindrical ion trap (CIT) mass analyzer, is used to perform ion/molecule reactions in order to improve selectivity for in situ analysis of explosives and chemical warfare agent simulants. Six different reactions are explored, including several of the Eberlin reaction type (M. N. Eberlin and R. G. Cooks, Org. Mass Spectrom., 1993, 28, 679-687) as well as novel gas-phase Meerwein reactions. The reactions include (1) Eberlin transacetalization of the benzoyl, 2,2-dimethyloximinium, and 2,2-dimethylthiooximinium cations with 2,2-dimethyl-1,3-dioxolane to form 2-phenyl-1,3-dioxolanylium cations, 2,2-dimethylamine-1,3-dioxolanylium cations and the 2,2-dimethylamin-1,3-oxathiolanylium cations, respectively; (2) Eberlin reaction of the phosphonium ion CH3P(O)OCH3+, formed from the chemical warfare agent simulant dimethyl methylphosphonate (DMMP), with 1,4-dioxane to yield the 1,3,2-dioxaphospholanium ion, a new characteristic reaction for phosphate ester detection; (3) the novel Meerwein reaction of the ion CH3P(O)OCH3+ with propylene sulfide forming 1,3,2-oxathionylphospholanium ion; (4) the Meerwein reaction of the benzoyl cation with propylene oxide and propylene sulfide to form 4-methyl-2-phenyl-1,3-dioxolane and its thio analog, respectively; (5) ketalization of the benzoyl cation with ethylene glycol to form the 2-phenyl-1,3-dioxolanylium cation; (6) addition/NO2 elimination involving benzonitrile radical cation in reaction with nitrobenzene to form an arylated nitrile, a diagnostic reaction for explosives detection and (7) simple methanol addition to the C7H7+ ion, formed by NO2 loss from the molecular ion of p-nitrotoluene to form an intact adduct. Evidence is provided that these reactions occur to give the products described and their potential analytical utility is discussed.

Chemical Warfare Agents↗

Solid phase micro-extraction in a miniature ion trap mass spectrometer.

Fiber introduction mass spectrometry (FIMS), a variation of solid-phase microextraction (SPME) and membrane introduction mass spectrometry (MIMS), is employed with a miniature mass spectrometer. The inlet system, constructed of commercially available vacuum parts, allows the direct introduction of the SPME needle vacuum chamber into the mass spectrometer. Thermal desorption of the analyte from the poly(dimethylsiloxane) (PDMS) coated fiber was achieved with a built in nichrome heater, followed by electron ionization of the analytes internal to the cylindrical ion trap (CIT). The system has been tested with several volatile organic compounds (VOC) in air and to analyze the headspace over aqueous solutions, with limits of detection in the low ppb range. The signal rise (10-90%) and fall (90-10%) times for the system ranged from 0.1 to 1 s (rise) and 1.2 to 6 s (fall) using heated desorption. In addition, this method has been applied to quantitation of toluene in benzene, toluene, xylene (BTX) mixtures in water and gasoline. This simple and rapid analysis method, coupled to a portable mass spectrometer, has been shown to provide a robust, simple, rapid, reproducible, accurate and sensitive (low ppb range) fieldable approach to the effective in situ analysis of VOC in various matrices.

Ions↗

Miniature cylindrical ion trap mass spectrometer.

A miniature cylindrical ion trap mass spectrometer is described, and preliminary data are presented. Functionality and performance of laboratory-scale instruments have been maintained to the extent possible in this battery-operated mass spectrometer. Capabilities include tandem mass spectrometry experiments. Custom-designed electronic components include the RF scanning and amplification system, data acquisition components, and lens power supplies, as well as a custom-software application. Direct leak and membrane introduction inlet systems are used for sample introduction. A mass/charge range of approximately 250 Th with unit mass resolution has been demonstrated.

Journal Article↗

Analytical performance of a miniature cylindrical ion trap mass spectrometer.

The analytical performance of a fieldable cylindrical ion trap (CIT)-based miniature mass spectrometer is described. A detailed description of the instrument itself is to be found in the immediately preceding paper (Patterson, G. E.; Guymon, A. J.; Riter, L S.; Everly, M.; Griep-Raming, J.; Laughlin, B. C.; Ouyang, Z.; Cooks, R. G., Miniature Cylindrical Ion Trap Mass Spectrometer, Anal. Chem. 2002, 24, 6145-6153). Applications employing the MS/MS and MSn capabilities of the miniature instrument and analytical performance criteria are given here. The limit of detection for methyl salicylate, introduced as the pure vapor, is estimated as 1 pg. The resolution, R = m/delta m, where delta m, measured as full width at half-maximum, is estimated as 100. Monitoring of organic compounds in air is performed using a permeation membrane introduction device coupled to the mass spectrometer. Water monitoring is performed using an external membrane introduction mass spectrometry (MIMS) system, with acetophenone and toluene serving as model compounds. Data are given for chemical warfare agent simulants, methyl salicylate, and dimethyl methyl phosphonate (DMMP) in air. On-line detection of menthol vapor emitted from a cough drop is reported. Methyl salicylate in air gives a recognizable mass spectrum at 400 ppb in the ambient system, while use of a heated membrane brings the detection limit down to 10 ppb.

Journal Article↗

Direct analysis of volatile organic compounds in human breath using a miniaturized cylindrical ion trap mass spectrometer with a membrane inlet.

Membrane introduction mass spectrometry (MIMS) coupled to a miniature mass spectrometer equipped with a cylindrical ion trap (CIT) analyzer was used to monitor the flavor components, 3-phenyl-2-propenal and methyl salicylate, found in cinnamon and wintergreen candies, respectively, directly from human breath. The poly(dimethylsiloxane) (PDMS) membrane was operated in a trap-and-release mode, where the temperature of the membrane was cycled during the experiments, which permitted temporal resolution of the two compounds of interest, facilitating their observation in the complex sample. Under these thermally driven conditions, the 10-90% rise times for both compounds are similar (15 s for methyl salicylate, 17 s for 3-phenyl-2-propenal), but the difference in diffusivity means that the signal for 3-phenyl-2-propenal is delayed and the 10% point occurs 6 s later than that for wintergreen. Additional specificity needed for complex samples was gained by using tandem mass spectrometry.

Acrolein↗

Use of lysozyme as a standard for evaluating the effectiveness of a proteomics process.

Automated sequencing of unknowns in bottom-up proteomics makes the data produced susceptible to process control errors, which can be propagated into mistakes in analyte identification. Inclusion of an unintrusive internal standard, such as lysozyme, allows monitoring all phases of the proteomics process including sample preparation, enzymatic digestion, HPLC, mass spectrometry, and database searching. By using this internal standard, digestion issues including rearrangements, semi-tryptic fragments, and modifications were monitored. In addition, control of the HPLC process including column performance was achieved. The use of the lysozyme standard allowed easy optimization of mass spectral conditions including data dependent and collision induced dissociation settings. The use of this internal standard in a study of differential protein expression in rat serum samples is presented.