PubMed Health⌕ Search

Biomedical subjects

Lee L Swanstrom

Publications and source records attributed to Lee L Swanstrom.

At least 19 recordsLinked to original sources

Beta test results of a new system assessing competence in laparoscopic surgery.

BACKGROUND: There is currently a need for objective measures of surgical competence. Such measures should assess knowledge, judgment, and manual skills. The Fundamentals of Laparoscopic Surgery (FLS) program was developed by the Society of American Gastrointestinal and Endoscopic Surgeons to meet these criteria. The FLS assessment includes a multiple-choice cognitive test and a manual skills test. We present the results of validation studies of this novel assessment tool. STUDY DESIGN: Beta testing of the FLS examination was undertaken at 7 sites by 70 surgeons representing 4 levels of experience and training. Surgeons provided information about their prior experience and indicated a self-assessment of their laparoscopic competence. Results were assessed by ANOVA followed by orthogonal contrasts. RESULTS: Cognitive performance by training level: There was no difference between fellows and staff in percentage of questions answered correctly, but there was a discrepancy between junior and senior residents and between residents and senior surgeons (p < 0.01). Cognitive performance by laparoscopic experience quartiles: There were notable contrasts between the first and second quartiles of experience (p < 0.02) and between the third and fourth quartiles (p < 0.01). No marked difference was found between the second and third quartiles. Cognitive performance compared with self-assessment: Test results were substantially different (p < 0.01) between test-takers who assessed themselves as "better than average" and those who assessed themselves as "average" or "below average." Manual skills performance by training level: The major difference was found between junior residents versus senior residents, fellows or staff (p < 0.01). Manual skills performance by laparoscopic experience level: Differences were primarily seen between the first two quartiles and the last two quartiles of laparoscopic experience (p < 0.001). Manual skills performance compared with self-assessment: Those who assessed themselves as "above average" in laparoscopic skill performed markedly better than those indicating they had "average" or "below average" skill (p < 0.01). CONCLUSIONS: Beta test results for the FLS examination demonstrate satisfactory reliability, appropriate psychometric properties, and substantial initial validity. The FLS project is one of the first validated surgical education efforts to assess the competence of surgeons in a specific field.

Aptitude↗

[Current technology development for natural orifice transluminal endoscopic surgery].

Natural orifice transluminal endoscopic surgery (NOTES) is a novel concept which combines aspects of flexible endoscopy with laparoscopic surgery with the aim of creating a new field of patient friendly "incisionless" surgery. This will require novel advanced technologies to be developed specifically for NOTES. We discuss the technical requirements and the process of creating NOTES instrumentation and illustrate the process with some current enabling devices. The development process is outlined, including the requirements for NOTES, the current technology that can be used, and some prototype devices for access, retraction, and tissue approximation. Endoscopes for NOTES must have high resolution, large instrument channels, some degree of triangulation, and the ability to lock into position inside the abdominal cavity. Instrumentation should echo the capabilities of current laparoscopic tools. They should be large and sturdy, torque-able, and offer the full spectrum of end-effectors. Finally, NOTES technology must permit secure, tailorable tissue approximation. The "R" scope from Olympus and the Transport scope from USGI Medical are possible solutions to the design requirements for access and visualization. Eagle Claw (Olympus), The Swain system (Ethicon), and the G-prox (USGI) are current tissue approximation systems under development and investigation in clinical trials. NOTES is a potential advance in surgical care. This new approach requires the development of new platform devices, tailored to allow the safe and effective practice of this advanced endoscopic approach.

Endoscopes↗

Bringing order to the chaos: developing a matching process for minimally invasive and gastrointestinal postgraduate fellowships.

BACKGROUND: Since 1993, there has been an increase in the number of postgraduate fellowships in minimally invasive and gastrointestinal (GI) surgery; from 9 in 1993 to more than 80 in 2004. Early on, there was no supervision or accreditation of these fellowships, and they varied widely in content, structure, and quality. This was widely recognized as being a bad situation for fellow applicants and reflected poorly on the specialties of minimally invasive (MI) and GI surgery. In an effort to bring order to this chaotic situation, the Minimally Invasive Surgery Fellowship Council (MISFC) was founded in 1997. METHOD: In 2003, the MISFC was incorporated with 77 founding member programs. The goal of the MISFC was to develop guidelines for high-quality fellowship training, to provide a forum for the directors of MI and GI fellowships to exchange ideas, formulate training curricula; to establish uniform application and selection dates; and to create an equitable computerized match system for applicants. RESULTS: In 2004, the MISFC has increased to 95 members representing 154 postgraduate fellowship positions. The majority of these positions are primarily laparoscopic in focus, but other aspects of GI surgery including bariatric, general GI, flexible endoscopy, and hepatopancreatobiliary are also represented. Uniform application and selection dates were agreed on in 2001; and in 2003, the Council established a computerized Match, administered by the National Resident Match Program, which was used for the 2004 fellowship selection. A total of 113 positions were open for the match. A total of 248 applicants formally applied to MISFC programs and 130 participated in the match. Ninety-nine positions matched on the December 10th match day, and the remaining 14 programs successfully filled on the following scramble day. Seventeen applicants did not match to a program. Post match polling of program directors and applicants documented a high degree of compliance, usability, and satisfaction with the process. CONCLUSION: The MISFC has been successful at realizing its goals of bringing order to the past chaos of the MIS and GI fellowship situation. Its current iteration, the Fellowship Council, is in the process of introducing an accreditation process to further ensure the highest quality of postgraduate training in the fields of GI and endoscopic surgery.

Endoscopy, Gastrointestinal↗

Endoluminal methods for gastrotomy closure in natural orifice transenteric surgery (NOTES).

Natural orifice transenteric surgery (NOTES) is a new and rapidly evolving concept for intra-abdominal operations that offers the potential for a revolutionary advance in patient care. Conceptually, operations that currently require an open or laparoscopic approach could be performed without incisions in the abdomen, with their concomitant pain and scarring. A recent consensus statement by a joint group of gastrointestinal surgeons and gastroenterologists has identified several technical and technologic hurdles that would need to be overcome before NOTES becomes a clinical reality. One of the most significant requirements identified is the need for a very secure closure of the gastrotomy site that is required for scope passage and specimen removal. Although a rapidly expanding variety of transgastric procedures has been reported, only a few reports address the basic problem of gastrotomy closure. Availability of a safe and simple gastrotomy closure device, however, will be essential for the widespread adoption of the new field of NOTES. Unless new safe and simple devices for endoscopic gastrotomy closure are available and have proven efficacy, NOTES will remain in the hands of a few specialists at centers of excellence because the risk of complications due to insufficient gastrotomy closure will not be acceptable for the surgeon and gastroenterologist in general practice. In this article, we describe three new devices in development or newly on the market that are targeted to advance the safe endoscopic closure of gastrotomy from NOTES.

Endoscopy, Gastrointestinal↗

Forty-eight-hour pH monitoring increases sensitivity in detecting abnormal esophageal acid exposure.

Ambulatory 24-hour esophageal pH measurement is the standard for detecting abnormal esophageal acid exposure (AEAE), but it has a false negative rate of 15% to 30%. Wireless 48-hour pH monitoring (Bravo; Medtronic, Shoreview, MN) may allow more accurate detection of AEAE versus 24-hour pH monitoring. Forty-eight-hour wireless data were reviewed from 209 patients at three different tertiary care referral centers between 2003 and 2005. Manometric or endoscopic determination of the lower esophageal sphincter helped place the Bravo probe 5 to 6 cm above the lower esophageal sphincter. A total of 190 studies in 186 patients had sufficiently accurate data. There were 114 women and 72 men with an average age of 51 years. AEAE was defined by a Johnson-DeMeester score greater than 14.7 and was obtained in 115 of 190 studies (61%). Only 64 of 115 patients (56%) demonstrated AEAE for both days of the study, whereas 51 of 115 patients (44%) demonstrated AEAE in a single 24-hour period. There was no difference in the prevalence of AEAE on day 1 versus day 2 only (26% vs. 18%, P = .26). Compared with 24-hour alone data, 48-hour data showed 22% more patients with AEAE. Frequent day-to-day variability in patients with AEAE may be missed by a single 24-hour pH test. Forty-eight-hour pH testing may increase detection accuracy and sensitivity for AEAE by as much as 22%.

Female↗

Development of a new access device for transgastric surgery.

Flexible endoscope-based endoluminal and transgastric surgery for cholecystectomy, appendectomy, bariatric, and antireflux procedures show promise as a less invasive form of surgery. Current endoscopes and instruments are inadequate to perform such complex surgeries for a variety of reasons: they are too flexible and are insufficient to provide robust grasping and anatomic retraction. The lack of support for a retroflexed endoscope in the peritoneal cavity makes it hard to reach remote structures and makes vigorous retraction of tissues and organs difficult. There is also a need for multiple channels in scopes to allow use of several instruments and to provide traction/countertraction. Finally, secure means of tissue approximation are critical. The aim was to develop and test a new articulating flexible endoscopic system for endoluminal and transgastric endosurgery. A multidisciplinary group of gastrointestinal physicians and surgeons worked with medical device engineers to develop new devices and instruments. Needs assessments and design parameters were developed by consensus. Prototype devices were tested using inanimate models until usable devices were arrived at. The devices were tested in nonsurvival pigs and dogs. The devices were accessed through an incision in the wall of the stomach and manipulated in the peritoneal cavity to accomplish four different tasks: right upper quadrant wedge liver biopsy, right lower quadrant cecal retraction, left lower quadrant running small bowel, and left lower quadrant exposure of esophageal hiatus. In another three pigs, transgastric cholecystectomy was attempted. The positions of the device, camera, and endosurgical instruments, with and without ShapeLock technology, were recorded using laparoscopy and endoscopy and procedure times and success rates were measured. Instrument design parameters and their engineering solutions are described. Flexible multilumen guides which could be locked in position, including a prototype which allowed triangulation, were constructed. Features of the 18-mm devices include multidirectional mid body and/or tip angulation, two 5.5-mm accessory channels allowing the use of large (5-mm) flexible endosurgical instruments, as well as a 4-mm channel for an ultraslim prototype video endoscope (Pentax 4 mm). Using the resulting devices, the four designated transgastric procedures were performed in anesthetized animals. One hundred percent of the transgastric endosurgical procedures were accomplished with the exception of a 50% success for hiatal exposure, a 90% success rate for wedge liver biopsy, and a 33.3% success rate for cholecystectomy. A new endosurgical multilumen device and advanced instrumentation allowed effective transgastric exploration and procedures in the abdominal cavity including retraction of the liver and stomach to allow exposure of the gallbladder, retraction of the cecum, manipulation of the small bowel, and exposure of the esophageal hiatus. This technology may serve as the needed platform for transgastric cholecystectomy, gastric reduction, fundoplication, hiatus hernia repair, or other advanced endosurgical procedures.

Animals↗

Laparoscopic placement of hepatic artery infusion pumps: technical considerations and early results.

BACKGROUND: Laparoscopic hepatic artery infusion pump (LHAIP) placement is a novel treatment option for patients with colorectal liver metastases. This study investigates technical difficulties with regard to variant hepatic arteries and the preliminary outcomes for patients treated with LHAIP placement. METHODS: Between March 1998 and January 2003, 38 patients with colorectal metastases confined to the liver, 35 (92%) of who had prior systemic chemotherapy that failed, were treated with LHAIP. RESULTS: Twelve patients (32%) had LHAIP placement only, and 26 (68%) had pump placement combined with laparoscopic radiofrequency ablation (LRFA; 24 patients) and/or liver resection (2 patients). Variant hepatic arterial (HA) anatomy was present in 18 patients (47%). The presence of a variant HA did not increase pump complications, operative time, or blood loss (P >/=.20) or decrease the functional time of pump use (P =.91) in comparison with normal anatomy. In all patients with a variant HA, laparoscopic ligation of the variant vessel and/or cannulation of nongastroduodenal artery resulted in complete hepatic perfusion. Three misperfusions identified intraoperatively with use of methylene blue injection were corrected by laparoscopic ligation (two) or postoperative angioembolization (one). Postoperative pump radionuclide flow studies confirmed isolated hepatic artery infusion in all cases. There was a 13% pump-related complication rate. During a median follow-up of 11 months (0.5 to 35.5 months), the actuarial rate of overall survival was 47% and the estimated median survival time was 17.5 months. CONCLUSIONS: LHAIP placement is technically feasible, and variant HA is not associated with increased pump complications or decreased pump functional time.

Aged↗

Postoperative objective outcomes for upright, supine, and bipositional reflux disease following laparoscopic nissen fundoplication.

HYPOTHESIS: Traditionally, patients with gastroesophageal reflux disease fall into 3 categories based on 24-hour pH testing and the clinical occurrence of their acid exposure. Patients with upright reflux are believed to do worse following surgery compared with supine or bipositional reflux patients. We assessed objective postoperative outcomes for patients with upright, supine, and bipositional reflux following laparoscopic Nissen fundoplication to determine if there is a category of refluxing patient who should be counseled against antireflux surgery. DESIGN: Retrospective analysis of prospectively collected data. SETTING: Esophageal physiology laboratory at a tertiary care teaching hospital. PATIENTS: A total of 225 patients (supine, 45; upright, 92; bipositional, 88) with preoperative and postoperative 24-hour pH measurements, manometry results, and standardized symptom assessment forms were included in the study. INTERVENTIONS: A Nissen fundoplication was performed based on 24-hour pH and manometry result. Esophageal manometry was performed with a water-perfused system, and 24-hour pH was measured with a digital capture device. MAIN OUTCOME MEASURES: Preoperative and postoperative symptom correlation, 24-hour pH, and manometric variables. RESULTS: There was a significant difference in preoperative symptom correlation between groups. Patients with bipositional reflux disease have significantly worst reflux disease (percentage of time with a pH <4, total number of reflux episodes, longest reflux episode, and Johnson-DeMeester score) and the weakest preoperative lower esophageal sphincter pressure. Postoperative symptom correlation was low among all 3 groups. There was no significant difference in postoperative 24-hour pH or manometry among groups. Success following surgery was achieved in 73.3% with supine reflux, 80.4% with upright reflux, and 75.0% with bipositional reflux. CONCLUSIONS: Patients with bipositional reflux have the most severe disease. Supine, upright, and bipositional reflux patients perform equally well following laparoscopic fundoplication as defined by objective outcome criteria.

Adult↗

Expression of vascular endothelial growth factor and receptor flk-1 in colon cancer liver metastases.

BACKGROUND/PURPOSE: This study investigated vascular endothelial growth factor (VEGF) and flk-1 expression in hepatic metastases from colon carcinoma, and their associations with tumor angiogenesis, proliferation, and apoptosis. METHODS: Immunohistochemical studies were performed for VEGF/flk-1, Ki-67, p53, and bcl-2 expression, and microvessel density (MVD) in surgical specimens from 35 patients who underwent hepatectomy for colon cancer liver metastases between 1986 and 2001. RESULTS: VEGF and flk-1 were expressed mainly in the cytoplasm of tumor cells. High VEGF expression was associated with high flk-1 expression (P = 0.043). MVDs of less than 15 and 15 or more were found in 5 (14.3%) and 30 (85.7%) of 35 hepatic metastases, respectively. A Ki-67 index (KI) of 50% or more was detected in 33/35 (94.3%) of tumors, and 23 of these (65.7%) showed a KI of 85% or more. A KI of less than 50% was present in 2/35 (5.7%) of tumors. The expression of VEGF/flk-1 was related to elevated MVD (P < or = 0.026). VEGF was also associated with an increased KI (P = 0.025). Mutant p53 and bcl-2 expressions were detected in 26/35 (74.3%) and 17/35 (48.6%) of liver metastases, respectively. Mutant p53 was not related to VEGF/flk-1 expression, but bcl-2 was highly associated with flk-1 (P = 0.007). The incidences of high flk-1 expression and a KI of 85% or more were significantly higher in tumors which were both p53- and bcl-2-positive (93.3% and 73.3%) than in tumors which were negative for both (42.9% and 14.3%; P < or = 0.021). CONCLUSIONS: The VEGF-flk-1 system takes part in tumor angiogenesis, proliferation, and apoptosis in colon liver metastases. The bcl-2 pathway may upregulate VEGF activity via the flk-1 receptor. These findings are preliminary, requiring a larger sampling in order to elucidate the role of VEGF/flk-1 in metastatic colon cancer.

Adult↗

Full-thickness intraperitoneal excision by transanal endoscopic microsurgery does not increase short-term complications.

PURPOSE: Transanal endoscopic microsurgery (TEM) is a minimally invasive technique for full-thickness excision of benign and malignant rectal neoplasms located 4 to 24 cm above the anal verge. Entrance into the peritoneal cavity during TEM has been regarded as a complication that mandates conversion to open laparotomy for adequate repair of the defect. This study compares the rate of complications arising from TEM with and without intraperitoneal entry. METHODS: Patients undergoing peritoneal entry were compared to those who did not. RESULTS: No perioperative deaths occurred. There was no significant difference in the incidence of postoperative complications. No major complications occurred with peritoneal entry, and all peritoneal entries were closed transanally via endoscope. CONCLUSIONS: Entry into the peritoneum during TEM is not associated with an increased incidence of complication. Entry into the peritoneum during TEM excision does not mandate conversion to open laparotomy but may be safely repaired endoscopically. Lesions likely to be above the peritoneal reflection and within reach of the endoscope (4 to 24 cm) should be considered for TEM excision.

Aged↗

Laparoscopic biliary reconstruction.

BACKGROUND: Biliary reconstruction represents a relatively untested frontier in laparoscopy. METHODS: Retrospective review of all patients who underwent laparoscopic biliary operations at Legacy Health System from 1998 to 2003. RESULTS: Seven patients underwent laparoscopic biliary reconstruction. Indications included benign calculous disease in 4 patients, benign stricture on 1 patient, choledochal cyst in 1 patient, and malignant biliary obstruction in 1 patient. Operations performed included choledochoduodenostomy, hepaticojejunostomy, stricturoplasty, choledochal cyst excision with hepaticojejunostomy, and cholecystojejunostomy. Median operative time was 300 minutes. Median hospital stay was 4 days. One perioperative complication of a bowel obstruction required reoperation. Median follow-up was 15 months. One patient died of metastatic cancer 8 months after surgery. All other patients are symptom free with no signs of stricture or recurrent biliary obstruction. CONCLUSIONS: Laparoscopic biliary reconstruction represents a viable treatment option in carefully selected patients.

Adult↗

Endoscopic appraisal of the gastroesophageal valve after antireflux surgery.

OBJECTIVES: Little consensus exists regarding the endoscopic assessment of the esophagogastric junction after antireflux surgery. The purpose of this report is to characterize the gastroesophageal valve appearance unique to each type of antireflux procedure and to introduce an endoscopic lexicon by which to describe this anatomic region. METHODS: Endoscopic images were obtained from patients who had undergone any one of the following procedures: Nissen, Collis-Nissen, Toupet, and Dor fundoplications and Hill repair. Images were excluded if patients had any symptoms of heartburn, regurgitation, dysphagia, chest pain, or gas bloat or if they were using antisecretory medication. Seven photographs per operation type were evaluated by experienced surgeons and gastroenterologists tasked with describing defining characteristics of each procedure. RESULTS: Ten valve criteria were developed to uniquely identify and quantify the ideal endoscopic appearance of each procedure. Illustrations were created to clearly depict those traits. CONCLUSIONS: Using 10 gastroesophageal valve criteria, the key components of a successful functional repair of the esophagogastric junction were defined. These criteria can be employed when evaluating upper gastrointestinal complaints after antireflux surgery and may ultimately serve as a dependable outcome measure.

Esophagogastric Junction↗

Extended transmediastinal dissection: an alternative to gastroplasty for short esophagus.

HYPOTHESIS: The significance of short esophagus and its impact on failure after laparoscopic Nissen fundoplication are unknown. Although patients with severe esophageal shortening that requires Collis gastroplasty comprise a small percentage of patients undergoing fundoplication, we hypothesize that patients with moderate esophageal shortening requiring extended mediastinal dissection make up a larger subgroup and that extended laparoscopic mediastinal dissection is a good treatment strategy for such patients. DESIGN AND SETTING: Retrospective comparative analysis in an academic and private practice-based tertiary referral center. PATIENTS: A total of 205 patients underwent laparoscopic Nissen fundoplication for gastroesophageal reflux disease or paraesophageal hernias over 4 years. Outcomes in patients requiring either a type I (<5 cm) or type II (>5 cm) mediastinal dissection were compared. INTERVENTIONS: Laparoscopic Nissen fundoplication with or without extended mediastinal dissection and esophageal physiology testing. MAIN OUTCOME MEASURES: Symptom assessments, operative reports, and outcomes were prospectively recorded on standardized data sheets. Postoperative symptom assessment and esophageal physiology testing were performed. RESULTS: A total of 133 (65%) of the 205 patients underwent type I dissection, and 72 (35%) of the 205 patients underwent type II dissection. Failure occurred in 15 (11%) of 133 patients and 6 (10%) of 72 patients, respectively. The presence of a large hiatal or paraesophageal hernia predicted the need for type II dissection. CONCLUSIONS: No difference was seen in failure rates between patients who required a type II dissection and those who did not. This finding suggests that aggressive application of laparoscopic transmediastinal dissection to obtain adequate esophageal length may reduce fundoplication failure in patients with esophageal shortening and provide a success rate similar to that of patients with normal esophageal length. More liberal application of Collis gastroplasty in these patients is not warranted.

Chi-Square Distribution↗

Electrical stimulation of the vagus nerve restores motility in an animal model of achalasia.

Esophageal peristalsis generally does not return to normal after surgical treatment of achalasia. Direct electrical stimulation of the vagus nerve is known to stimulate antegrade peristalsis in the normal esophagus; however, it is not known whether electrical stimulation will induce return of peristalsis once an achalasia-like disorder has been established. The objective of this study was to perform quantitive and qualitative measurements of motility during electrical stimulation of the vagal nerve in an animal model of achalasia. An already established and verified animal achalasia model using adult North American opossums (Didelphis virginiana) was used. Fifteen opossums were divided into three groups. Sham surgery was performed on three animals (group 1). In group 2 (n=6) a loose Gore-Tex band (110% of the esophageal circumference) was placed around the gastroesophageal junction to prevent relaxation of the lower esophageal sphincter during swallowing. In group 3 (n=6) a relatively tighter band (90% of the esophageal circumference) was used to further elevate the lower esophageal sphincter pressure. At 6 weeks, after manometric and radiolologic confirmation of achalasia, electrical stimulation of the esophagus was performed before and after removal of the band using a graduated square-wave electrical stimulus. Changes in esophageal neural plexi were assessed histologically. Pre- and postoperative manometric data were compared using standard statistical techniques. No difference was observed in esophageal characteristics and motility after sham surgery in group 1. Animals in group 2 demonstrated a vigorous variety of achalasia (high-amplitude, simultaneous, repetitive contractions), moderate esophageal dilatation, and degeneration of 40% to 60% of intramuscular nerve plexi. Animals in group 3 developed amotile achalasia with typical low-amplitude simultaneous (mirror image) contractions, severely dilated ("bird beak") esophagus, and degeneration of 50% to 65% of nerve plexi. Vagal stimulation in group 2 demonstrated a significant increase in the amplitude of contractions (P<0.001) and return of peristaltic activity in 49% of swallows before band removal. After band removal, all of the contractions were peristaltic. In group 3 vagal stimulation before and after removal of the band demonstrated a significant increase in amplitude of contractions (P<0.0001) but no return of propagative peristalsis before band removal, however, 44% of contractions were progressive in the smooth portion of the esophagus after removal of the band. Electrical stimulation of the vagus nerve improved the force of esophageal contractions irrespective of the severity of the disease; however, peristaltic activity completely returned to normal only in the vigorous (early) variety of achalasia. Removal of the functional esophageal outlet obstruction, as with a surgical myotomy, may be necessary to obtain significant peristalsis with vagal pacing in severe achalasia.

Animals↗

Cohort study of surgical bypass to the gallbladder or bile duct for the palliation of jaundice due to pancreatic cancer.

OBJECTIVE: To compare patterns in mortality and the use of subsequent biliary drainage interventions (surgical, endoscopic, and percutaneous) associated with the different types of biliary bypass. SUMMARY BACKGROUND DATA: Surgical palliation of obstructive jaundice due to pancreatic cancer is often accomplished with an intestinal bypass to either the gallbladder or the bile duct. It is not known whether a gallbladder bypass, which is a simpler operation and more amenable to laparoscopic surgery, performs as well as a bypass to the bile duct. METHODS: The authors conducted a retrospective cohort study of 1,919 patients 65 years of age or older who had a surgical biliary bypass for pancreatic cancer diagnosed between 1991 and 1996 using Medicare claims data and the Surveillance, Epidemiology and End Results (SEER) database. RESULTS: At 1, 2, and 5 years, 7.5%, 17.4%, and 26.0% of 945 patients initially treated with a gallbladder bypass had additional biliary interventions, as compared with 2.9%, 11.0%, and 13.3% of 974 patients initially treated with a bile duct bypass. Patients who initially had a gallbladder bypass were 4.4 times as likely to have additional biliary surgery and 2.9 times as likely to have any subsequent biliary intervention as were patients who initially had a bile duct bypass. Median survival was longer following bile duct bypass. The adjusted hazard ratio for death associated with gallbladder bypass was 1.2. CONCLUSIONS: Compared to patients whose initial biliary bypass was to the bile duct, the risk of having one or more additional surgical, endoscopic, or percutaneous biliary drainage procedures is substantially greater in patients whose initial bypass was to the gallbladder.

Aged↗

The effect of laparoscopy on survival in pancreatic cancer.

HYPOTHESIS: Exposure to laparoscopy influences survival in patients with unresected pancreatic cancer who have a diagnostic or staging surgical procedure. METHODS: We used the Surveillance, Epidemiology, and End Results Medicare-linked database to identify a cohort of persons 65 years and older, who were newly diagnosed with primary pancreatic cancer between 1991 and 1996 and who had a diagnostic laparoscopy or laparotomy during the course of their disease. Patients with a prior malignancy and those who had a pancreatic resection were excluded. We used proportional-hazards regression to adjust risk estimates for demographic factors, medical comorbidities, tumor characteristics, and the use of other treatment modalities. RESULTS: We identified 112 individuals with pancreatic cancer who had a laparoscopic procedure and 791 who had only conventional surgery. More patients who had laparoscopic surgery had distant metastases at diagnosis (67.9% vs 41.2%; P =.001). Median duration of survival in the laparoscopic surgery group was 4.8 months (95% confidence interval [CI], 4.1-6.8) compared with 5.3 months in the group that had only open surgery (95% CI, 4.9-5.6; P =.83). Compared with patients who only had a laparotomy, patients who had laparoscopic surgery did not have an increased rate of death when adjusted for the effects of age, sex, tumor size, grade, the presence of nodal and distant metastases at diagnosis, and the use of radiation, chemotherapy, therapeutic endoscopic retrograde cholangiopancreatography, and biliary and gastric bypass (adjusted hazard ratio, 0.93; 95% CI, 0.62-1.40). CONCLUSION: Exposure to laparoscopic surgery did not adversely affect survival in a cohort of elderly patients with pancreatic cancer who had a diagnostic procedure but no pancreatic resection.

Aged↗

Postoperative symptoms and failure after antireflux surgery.

BACKGROUND: Outcomes in patients having surgery for gastroesophageal reflux disease are most commonly determined by symptomatic assessment. Objective testing is usually reserved for symptomatic patients. HYPOTHESIS: To evaluate the relationship between symptomatic and objective outcomes after antireflux surgery. DESIGN: Retrospective analysis of prospectively collected data. SETTING: A tertiary care teaching hospital with a comprehensive esophageal physiology laboratory. INTERVENTIONS: A 360 degrees (Nissen) fundoplication or a 270 degrees (Toupet) posterior fundoplication was performed based on esophageal motility. Twenty-four-hour pH monitoring was used as a gold standard for assessing postoperative acid reflux. PATIENTS: Two hundred nine consecutive patients with preoperative and postoperative symptomatic and objective testing performed between January 1, 1996, and June 15, 2001. MAIN OUTCOME MEASURES: Data on preoperative and postoperative symptoms, DeMeester scores, and esophageal motility were prospectively collected. Objective testing was performed after at least 6 months. RESULTS: The preoperative median DeMeester score was 50.0 (interquartile [IQ] range, 30.3-87.0). One hundred eighty patients had a Nissen and 29 patients had a Toupet fundoplication. After a median postoperative interval of 7.7 months (IQ range, 6.7-9.5 months), 174 patients (83.3%) had normal DeMeester scores (median, 2.2; IQ range, 0.8-5.0; P<.001). Of 58 patients (27.7%) who had reflux symptoms after surgery, only 17 (29.3%) had abnormal DeMeester scores (median, 36.9; IQ range, 748.4-20.0; P =.001). Eighteen (11.9%) of the 151 asymptomatic patients had abnormal DeMeester scores (median, 32.5; IQ range, 22.2-57.5; P =.006). CONCLUSIONS: There is poor correlation between postoperative reflux symptoms and actual reflux (abnormal DeMeester scores). Surgeons must be careful to define their terms when reporting success or failure rates after antireflux surgery. Routine use of medical therapy for suppressing postoperative gastroesophageal reflux disease symptoms is not supported by these data, and postoperative therapy should be based on objective testing only.

Female↗