An MLC-based linac QA procedure for the characterization of radiation isocenter and room lasers' position.

We have designed and implemented a new stereotactic linac QA test with stereotactic precision. The test is used to characterize gantry sag, couch wobble, cone placement, MLC offsets, and room lasers' positions relative to the radiation isocenter. Two MLC star patterns, a cone pattern, and the laser line patterns are recorded on the same imaging medium. Phosphor plates are used as imaging medium due to their sensitivity to red light. The red light of room lasers erases some of the irradiation information stored on the phosphor plates enabling accurate and direct measurements for the position of room lasers and radiation isocenter. Using film instead of the phosphor plate as imaging medium is possible, however, it is less practical. The QA method consists of irradiating four phosphor plates that record the gantry sag between the 0 degrees and 180 degrees gantry angles, the position and stability of couch rotational axis, the sag between the 90 degrees and 270 degrees gantry angles, the accuracy of cone placement on the collimator, the MLC offsets from the collimator rotational axis, and the position of laser lines relative to the radiation isocenter. The estimated accuracy of the method is +/- 0.2 mm. The observed reproducibility of the method is about +/- 0.1 mm. The total irradiation/ illumination time is about 10 min per image. Data analysis, including the phosphor plate scanning, takes less than 5 min for each image. The method characterizes the radiation isocenter geometry with the high accuracy required for the stereotactic radiosurgery. In this respect, it is similar to the standard ball test for stereotactic machines. However, due to the usage of the MLC instead of the cross-hair/ball, it does not depend on the cross-hair/ball placement errors with respect to the lasers and it provides more information on the mechanical integrity of the linac/couch/laser system. Alternatively, it can be used as a highly accurate QA procedure for the nonstereotactic machines. Noteworthy is its ability to characterize the MLC position accuracy, which is an important factor in IMRT delivery.

Journal Article↗

Deformable structure registration of bladder through surface mapping.

Cumulative dose distributions in fractionated radiation therapy depict the dose to normal tissues and therefore may permit an estimation of the risk of normal tissue complications. However, calculation of these distributions is highly challenging because of interfractional changes in the geometry of patient anatomy. This work presents an algorithm for deformable structure registration of the bladder and the verification of the accuracy of the algorithm using phantom and patient data. In this algorithm, the registration process involves conformal mapping of genus zero surfaces using finite element analysis, and guided by three control landmarks. The registration produces a correspondence between fractions of the triangular meshes used to describe the bladder surface. For validation of the algorithm, two types of balloons were inflated gradually to three times their original size, and several computerized tomography (CT) scans were taken during the process. The registration algorithm yielded a local accuracy of 4 mm along the balloon surface. The algorithm was then applied to CT data of patients receiving fractionated high-dose-rate brachytherapy to the vaginal cuff, with the vaginal cylinder in situ. The patients' bladder filling status was intentionally different for each fraction. The three required control landmark points were identified for the bladder based on anatomy. Out of an Institutional Review Board (IRB) approved study of 20 patients, 3 had radiographically identifiable points near the bladder surface that were used for verification of the accuracy of the registration. The verification point as seen in each fraction was compared with its predicted location based on affine as well as deformable registration. Despite the variation in bladder shape and volume, the deformable registration was accurate to 5 mm, consistently outperforming the affine registration. We conclude that the structure registration algorithm presented works with reasonable accuracy and provides a means of calculating cumulative dose distributions.

Algorithms↗

Dosimetric consequences of manual pullback procedure for coronary artery radiotherapy with 90Sr/90Y beta-source.

PURPOSE: This work presents a quantitative dosimetric analysis of the Novoste (90)Sr/(90)Y beta-source cardiovascular brachytherapy treatments using a manual pullback technique for patients with in-stent restenosis. METHODS AND MATERIALS: Based on our previous measurements, a model was developed to estimate the dose in the middle of the junction region for tandem irradiation expressed as fraction of prescription dose (FPD) and dosimetric overlap length (DOL) receiving more/less than a threshold dose. The overlap/gap size was measured using the digital cine images recorded during treatment and then FPD and DOL were quantified. RESULTS: Statistical analysis of 55 patients showed that the overlap size and the FPD at 2 mm radial distance were in range of 0 to 23 mm and 13-200% of prescription dose (Rx), respectively. Four gaps out of 76 pullback cases were found, but their size was at most 5 mm. CONCLUSION: Use of a 5 mm overlap avoided underdosed regions in the vast majority of the cases. These results are the first step towards an analysis of the clinical outcome of these patients.

Brachytherapy↗

GAF film dosimetry of a tandem positioned beta-emitting intravascular brachytherapy source train.

Coronary artery brachytherapy may require treatment of lesions longer than a single source length. A treatment option is tandem positioning of the single source. This study presents relative dosimetric measurements of a cardiovascular brachytherapy source and the dosimetric characteristics in the junction region of tandem treatments. Measurements were carried out using a Novoste Beta Cath 90Sr/90Y 40 mm beta source in a plastic water phantom. Radiochromic MD-55-2 film, calibrated using both 6 MV photon and 6 MeV electron beams from a linear accelerator, was used as the dosimeter. Dose distributions around a single source and in the junction region of tandem irradiation were measured. Measurements of the near field dose as close as 1.2 mm from the source are presented. Significant over- or underdoses in the junction region of tandem irradiation were quantified. At a radial distance of 2 mm from the longitudinal axis of the source, the dose value in the middle of the junction region, normalized to the dose at 2 mm midline single source, was about 182% for a 2-seed overlap and 16% for a 2-seed gap, respectively. Dose distributions in the junction region as a function of source overlap and radial distance have fairly high gradients and exhibit characteristic patterns. The fraction of prescription dose was found to have a sigmoidal dependence on overlap size, for radial distances ranging between 1.2 and 3 mm. The parameters of these sigmoids, quantified as functions of radial distance, could be used to provide quick and reasonable over/underdose estimates, given any potential overlap or gap in the junction area, with an uncertainty within 10%.

Beta Particles↗