Evaluation of four postprocessing methods for determination of cerebral blood volume and mean transit time by dynamic susceptibility contrast imaging.

Four different postprocessing methods to determine cerebral blood volume (CBV) and contrast agent mean transit time (MTT) by dynamic susceptibility contrast (DSC) MRI were compared. CBV was determined by two different methods that integrate tracer concentration-time curves numerically and by two other methods that take recirculation into account. For the two methods that use numerical integration, one method cuts the integration after the first pass while the other method integrates over the whole time series. For the two methods that account for recirculation, one method uses a gamma-variate fit, whereas the other method utilizes tissue impulse response. All four methods determine MTT as the ratio of CBV and cerebral blood flow (CBF). In each case, CBF was obtained as the height of the impulse response obtained by deconvolving the tissue concentration-time curves with a noninvasively determined arterial input function. Monte Carlo simulations were performed to determine the reliability of the methods and the validity of the simulations was supported by observation of similar trends in 13 acute stroke patients. The method of determining CBV and subsequently MTT was found to affect the measured value especially in areas where MTT is prolonged, but had no apparent effect on the visually determined hypoperfusion volumes.

Aged↗

Final infarct size after acute stroke: prediction with flow heterogeneity.

PURPOSE: To compare acute measurements of flow heterogeneity (FH) and mean transit time (MTT) with follow-up data to determine which method yields better predictive measures of final infarct volumes. MATERIALS AND METHODS: Twenty-three patients with symptoms of stroke underwent magnetic resonance (MR) imaging during the acute stage, and the tissue at risk was estimated from MTT maps and maps generated by means of detecting abnormal FH. Final infarct volumes were calculated from T2-weighted follow-up MR image measurement. The Wilcoxon signed rank test was performed to compare the two predictive maps (MTT and FH) with T2-weighted follow-up maps. RESULTS: Eleven (48%) patients experienced infarct growth. Both the MTT and the FH maps enabled prediction of 10 of these cases. There were five false-positive cases with MTT measurement but three with FH measurement. In terms of predicting final infarct volumes, the final infarct size on the MTT maps was overestimated by 75%. The final infarct size on the FH maps also was overestimated, but by only 15%. MTT map measurements were significantly different from follow-up MR image measurements (P =.005), but FH map measurements were not (P =.059). CONCLUSION: FH maps may enable more precise prediction of final infarct volume in stroke patients.

Acute Disease↗

Magnetic resonance perfusion-weighted imaging of acute cerebral infarction: effect of the calculation methods and underlying vasculopathy.

BACKGROUND AND PURPOSE: Various calculation methods are available to estimate the transit-time on MR perfusion-weighted imaging (PWI). Each method may affect the results of PWI. Steno-occlusive disease in the parent vessels is another factor that may affect the results of the PWI. The purpose of this study was to elucidate the effect of the calculation methods and underlying vasculopathy on PWI. METHODS: From a pool of 113 patients who had undergone PWI during the study period, a total of 12 patients with nonlacunar ischemic strokes who were scanned within 24 hours after onset of symptom were selected for the study. The patient population consisted of 6 patients who had extracranial internal carotid artery stenosis (>70%) and 6 individuals without stenosis. Seven different postprocessing methods were evaluated: first moment, ratio of area to peak, time to peak (TTP), relative TTP, arrival time, full-width at half-maximum, and deconvolution methods. Follow-up MR or CT images were used to determine the areas that evolved into infarcts, which served as the gold standard. Sensitivity and specificity of each transit time technique were calculated. RESULTS: Calculation methods with high sensitivity were the first moment (sensitivity, 74%), TTP (sensitivity, 77%), and deconvolution methods (sensitivity, 81% to 94%). Between the 2 groups with and without internal carotid artery stenosis, the specificity of most of the techniques was lower in the internal carotid artery stenosis group. The first moment and deconvolution methods maintained relatively high specificity even in the stenosis group. CONCLUSIONS: The calculation technique and presence of underlying vasculopathy have a direct impact on the results of PWI. The methods with high sensitivity even in the presence of steno-occlusive disease were the first moment and deconvolution methods with arterial input function derived from the peri-infarct arteries; the deconvolution method was the superior choice because of higher lesion conspicuity.

Acute Disease↗