PubMed Health⌕ Search

Biomedical subjects

Leonardo Bonato Felix

Publications and source records attributed to Leonardo Bonato Felix.

2 recordsLinked to original sources

Multivariate objective response detectors (MORD): statistical tools for multichannel EEG analysis during rhythmic stimulation.

The presence of cerebral evoked responses can be tested by using objective response detectors. They are statistical tests that provide a threshold above which responses can be assumed to have occurred. The detection power depends on the signal-to-noise ratio (SNR) of the response and the amount of data available. However, the correlation within the background noise could also affect the power of such detectors. For a fixed SNR, the detection can only be improved at the expense of using a longer stretch of signal. This can constitute a limitation, for instance, in monitored surgeries. Alternatively, multivariate objective response detection (MORD) could be used. This work applies two MORD techniques (multiple coherence and multiple component synchrony measure) to EEG data collected during intermittent photic stimulation. They were evaluated throughout Monte Carlo simulations, which also allowed verifying that correlation in the background reduces the detection rate. Considering the N EEG derivations as close as possible to the primary visual cortex, if N = 4, 6 or 8, multiple coherence leads to a statistically significant higher detection rate in comparison with multiple component synchrony measure. With the former, the best performance was obtained with six signals (O1, O2, T5, T6, P3 and P4).

Acoustic Stimulation↗

Avoiding spectral leakage in objective detection of auditory steady-state evoked responses in the inferior colliculus of rat using coherence.

Local field potentials (LFP) are bioelectric signals recorded from the brain that reflect neural activity in a high temporal resolution. Separating background activity from that evoked by specific somato-sensory input is a matter of great clinical relevance in neurology. The coherence function is a spectral coefficient that can be used as a detector of periodic responses in noisy environments. Auditory steady-state responses to amplitude-modulated tones generate periodic responses in neural networks that may be accessed by means of coherence between the stimulation signal and the LFP recorded from the auditory pathway. Such signal processing methodology was applied in this work to evaluate in vivo, anaesthetized Wistar rats, activation of neural networks due to single carrier sound stimulation frequencies, as well as to evaluate the effect of different modulating tones in the evoked responses. Our results show that an inappropriate choice of sound stimuli modulating frequencies can compromise coherence analysis, e.g. misleading conclusions due to mathematical artefact of signal processing. Two modulating frequency correction protocols were used: nearest integer and nearest prime number. The nearest prime number correction was successful in avoiding spectral leakage in the coherence analysis of steady-state auditory response, as predicted by Monte Carlo simulations.

Acoustic Stimulation↗