PubMed Health⌕ Search

Biomedical subjects

Li-xin Chen

Publications and source records attributed to Li-xin Chen.

6 recordsLinked to original sources

Effect of Astragalus membranaceus injection on the activity of the intestinal mucosal mast cells after hemorrhagic shock-reperfusion in rats.

BACKGROUND: The mechanism of mucosal damage induced by ischemia-reperfusion (IR) after hemorrhagic shock is complex; mast cells (MC) degranulation is associated with the mucosal damage. Astragalus membranaceus can protect intestinal mucosa against intestinal oxidative damage after hemorrhagic shock, and some antioxidant agents could prevent MC against degranulation. This study aimed to observe the effects of astragalus membranaceus injection on the activity of intestinal mucosal mast cells (IMMC) after hemorrhage shock-reperfusion in rats. METHODS: Thirty-two Wistar rats were randomly divided into the normal group, model group, low dosage group, (treated with Astragalus membranacaus injection, 10 g crude medication/kg) and high dosage group (treated with Astragalus membranacaus injection, 20 g crude medication/kg). The rat model of hemorrhagic shock-reperfusion was induced by hemorrhage for 60 minutes followed by 90 minutes of reperfusion. The animals were administrated with 3 ml of the test drug solution before reperfusion. At the end of study, intestinal pathology, ultrastructure of IMMC, and expression of tryptase were assayed. The levels of malondisldehyde (MDA), TNF-alpha, histamine, and superoxide dismutase (SOD) activity in intestine were detected, and the number of IMMC was counted. RESULTS: The Chiu's score of the rats in the model group was higher than in other groups (P < 0.01). The Chiu's score in the high dosage group was higher than that in the low dosage group (P < 0.05). Hemorrhage-reperfusion induced IMMC degranulation: Astragalus membranaceus injection attenuated this degranulation. Expression of tryptase and the number of IMMC in the model group increased compared with the other groups (P < 0.01) and was significantly reduced by the treatments of Astragalus membranaceus injection at both doses. There was no significant difference between the two treatment groups (P > 0.05). MDA content and concentration of TNF-alpha in the model group were higher than that in the other three groups (P < 0.05), and the concentration of TNF-alpha in the low dosage group was higher than that in the high dosage group (P < 0.05). SOD activity and the concentration of histamine in the model group were lower than the other three groups (P < 0.05). There was a negative correlation between the Chiu's score and the concentration of histamine and a positive correlation between the Chiu's score and the concentration of TNF-alpha and between the SOD activity and the concentration of histamine in the four groups (P < 0.05). CONCLUSION: Astragalus membranaceus injection may reduce the damage to small intestine mucosa by inhibiting the activated IMMC after hemorrhagic shock.

Animals↗

[Feasibility of muscle-derived cell autotransplantation as a treatment for post-prostatectomy urinary incontinence].

OBJECTIVE: To explore the feasibility of muscle-derived cell autotransplantation in the treatment of post-prostatectomy urinary incontinence. METHODS: Skeletal muscle-derived cells (MDC) were isolated and purified by replate technique from 6 female SD rats, and then transduced with adenovirus carrying Lac-Z gene. About 5 x 10(6) of the transduced cells were injected autologously into the bladder neck of the animals. Tissues were harvested after 5 and 15 days for histological examination and X-gal staining. RESULTS: At 5 and 15 days after the autologous MDC transplantation, histological examination revealed no apparent sign of inflammation and inflammatory cell invasion, and X-gal staining showed a large number of cells dyed blue, indicating the survival of the autologous cells. CONCLUSION: Autotransplanted MDCs can survive permanently. Autologous muscle stem cell injection can be an effective treatment for post-prostatectomy urinary incontinence.

Animals↗

Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects.

BACKGROUND: Both real-time three-dimensional echocardiography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy of RT3DE combined with MCE for quantitative evaluation of myocardial perfusion defects. METHODS: Thirteen dogs underwent ligation of the left anterior descending artery (LAD, n = 6) or distal branch of the left circumflex artery (LCX, n = 7) under general anaesthesia. Three to four ml of a perfluoropropane (C3F8) microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with a commercially available Philips SONOS-7500 ultrasound system. After removal of the dog hearts, Evans blue dye was injected via the left and right coronary arteries to stain the myocardium at risk. In vitro anatomic measurements of myocardial mass after removal of the animals' hearts were used as controls. RESULTS: Left ventricular (LV) mass determined by RT3DE ranged 36.7 - 68.9 g [mean, (54.6 +/- 9.6) g] before coronary artery ligation, and correlated highly (r = 0.99) with in vitro measurement of LV mass [range, 38.9 - 71.1 g; mean, (55.6 +/- 9.3) g]. There was no significant difference between RT3DE and in vitro measurements of LV mass [range, 36.7 - 68.9 g; mean, (51.3 +/- 12.5) g. Or range, 38.9 - 71.1 g; mean, (53.7 +/- 12.3) g, respectively] and under-perfused mass [range, 0 - 21.4 g; mean, (12.0 +/- 6.9) g. Or range, 0 - 19.8 g; mean, (10.8 +/- 6.3) g, respectively] after the LAD ligation (P > 0.05). Likewise, no significant difference was present between RT3DE and in vitro measurements of LV mass [range, 50.1 - 65.4 g; mean, (57.5 +/- 5.9) g. Or range, 51.5 - 65.8 g; mean, (57.3 +/- 6.4) g, respectively] and under-perfused mass [range, 0 - 25.6 g; mean, (13.3 +/- 9.6) g. Or range, 0 - 22.7 g; mean, (12.8 +/- 8.1) g, respectively] after the LCX ligation (P > 0.05). For all the animals with coronary ligation, LV mass measured by RT3DE ranged 35.9 - 68.6 g [mean, (54.8 +/- 10.0) g] and there was no significant difference between RT3DE and in vitro measurements of LV mass and under-perfused mass (P > 0.05, r = 0.99). Further, the under-perfused mass derived from RT3DE [range, 0 - 25.6 g; mean, (12.7 +/- 8.2) g] correlated strongly with the in vitro measurements [range, 0 - 22.7 g; mean, (11.9 +/- 7.2) g] (r = 0.96). CONCLUSION: RT3DE with MCE is a rapid and accurate method for estimating LV myocardial mass and quantifying perfusion defects.

Animals↗

Validation of real-time three-dimensional echocardiography for quantifying left and right ventricular volumes: an experimental study.

BACKGROUND: Assessment of the left ventricular (LV) and the right ventricular (RV) volumes and their functions is important for prognostic prediction and clinical decision making. We compared the accuracy for quantifying the LV and the RV volumes in vitro between conventional two-dimensional echocardiography (2DE) and real-time three-dimensional echocardiography (RT3DE). METHODS: The volumes of 37 rubber-models (10 regularly shaped to simulate normal LV, 7 shaped to simulate LV with symmetric aneurysm, 8 shaped to simulate LV with asymmetric aneurysm, and 12 irregularly shaped to simulate normal RV) and 10 excised canine hearts were measured by RT3DE and 2DE. On RT3DE "full volume" imaging, the inner-surfaces of the rubber-models and canine LV and RV were outlined and the volumes were measured using 2-, 4-, 8- and 16-plane methods with the RT3DE analysis software. On 2DE imaging, the volumes were measured by the Simpson method. The LV and RV volumes measured by drained water were served as reference values, with which we compared RT3DE and 2DE data. RESULTS: In rubber models mimicking normal LV and LV with symmetric aneurysms, RT3DE results were strongly correlated with reference values (r = 0.795 - 0.998) and there was a good correlation between 2DE estimates and reference values (r = 0.715 - 0.729). There were no significant differences between RT3DE estimates, 2DE results and reference values (P > 0.05). In rubber models mimicking the RV and LV with asymmetric aneurysm, RT3DE strongly correlated with reference values (r = 0.765 - 0.988), but 2DE weakly correlated with reference values (r = 0.518 - 0.592). There were no differences between RT3DE and reference values (P > 0.05), but a significant difference between 2DE and reference values occurred (P < 0.05). For excised canine hearts, there was a strong correlation between RT3DE and reference values (r = 0.728 - 0.914), while 2DE showed a less obvious correlation (r = 0.502 - 0.615). Again, there were no significant differences between RT3DE and reference values (P > 0.05), but there was a significant difference between 2DE and reference values (P < 0.05). CONCLUSIONS: RT3DE can accurately quantify LV and RV volumes and provides a new tool to evaluate LV and RV function. For LV and RV measurements by RT3DE, 8-plane strategy is the optimum choice for accuracy and convenience.

Animals↗

Real-time three-dimensional echocardiography for quantifying left ventricular mass.

OBJECTIVE: To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. METHODS: Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was measured using 2, 4, 8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length method. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. RESULTS: In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). CONCLUSION: RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience.

Animals↗

[Detection of chromosome 8 anomalies in ovarian carcinoma by fluorescence in situ hybridization].

OBJECTIVE: To detect the relationship between chromosomal anomalies and the pathogenesis, development and prognosis of ovarian carcinoma. METHODS: Thirty-six specimens of ovarian carcinoma (n=12), ovarian benign tumor (n=12), and normal ovary (n=12) were examined by fluorescence in situ hybridization (FISH). RESULTS: Twelve cases of mutations, including trisomy 8, monosomy 8 or tetraploid 8 chromosomal anomalies, were found in the group of ovarian carcinoma, making up 100% (12/12). Three cases of trisomy 8 chromosomal anomalies were found in the group of ovarian benign tumor, accounting for 25% (3/12). No anomaly was found in the normal group. There were significant differences between the three groups, P<0.001. CONCLUSION: The above anomalies of chromosome 8 are significantly associated with the pathogenesis and development of ovarian carcinoma. The anomalies may occur in the early stage of the carcinoma, and may be significantly associated with the pathological differentiation and clinical stage of the case.

Adolescent↗