PubMed Health⌕ Search

Biomedical subjects

Liam A McDonnell

Publications and source records attributed to Liam A McDonnell.

11 recordsLinked to original sources

Imaging of peptides in the rat brain using MALDI-FTICR mass spectrometry.

Analytical methods are pursued to measure the identity and location of biomolecules down to the subcellular (microm) level. Available mass spectrometric imaging methods either compromise localization accuracy or identification accuracy in their analysis of surface biomolecules. In this study, imaging FTICR-MS is applied for the spatially resolved mass analysis of rat brain tissue with the aim to optimize protein identification by the high mass accuracy and online MS/MS capabilities of the technique. Mass accuracies up to 6 ppm were obtained in the direct MALDI-analysis of the tissue together with a spatial resolution of 200 microm. The spatial distributions of biomolecules differing in mass by less than 0.1 Da could be resolved, and are shown to differ significantly. Online MS/MS analysis of selected ions was demonstrated. A comparison of the FTICR-MS imaging results with stigmatic TOF imaging on the same sample is presented. To reduce the extended measuring times involved, it is recommended to restrict the FTICR-MS analyses to areas of interest as can be preselected by other, faster imaging methods.

Animals↗

Higher sensitivity secondary ion mass spectrometry of biological molecules for high resolution, chemically specific imaging.

To expand the role of high spatial resolution secondary ion mass spectrometry (SIMS) in biological studies, numerous developments have been reported in recent years for enhancing the molecular ion yield of high mass molecules. These include both surface modification, including matrix-enhanced SIMS and metal-assisted SIMS, and polyatomic primary ions. Using rat brain tissue sections and a bismuth primary ion gun able to produce atomic and polyatomic primary ions, we report here how the sensitivity enhancements provided by these developments are additive. Combined surface modification and polyatomic primary ions provided approximately 15.8 times more signal than using atomic primary ions on the raw sample, whereas surface modification and polyatomic primary ions yield approximately 3.8 and approximately 8.4 times more signal. This higher sensitivity is used to generate chemically specific images of higher mass biomolecules using a single molecular ion peak.

Animals↗

Combined infrared multiphoton dissociation and electron-capture dissociation using co-linear and overlapping beams in Fourier transform ion cyclotron resonance mass spectrometry.

A novel set-up for Fourier transform ion cyclotron resonance mass spectrometry (FTICR) is reported for simultaneous infrared multiphoton dissociation (IRMPD) and electron-capture dissociation (ECD). An unmodified electron gun ensures complete, on-axis overlap between the electron and the photon beams. The instrumentation, design and implementation of this novel approach are described. In this configuration the IR beam is directed into the ICR cell using a pneumatically actuated mirror inserted into the ion-optical path. Concept validation was made using different combinations of IRMPD and ECD irradiation events on two standard peptides. The ability to perform efficient IRMPD, ECD and especially simultaneous IRMPD and ECD using lower irradiation times is demonstrated. The increase in primary sequence coverage, with the combined IRMPD and ECD set-up, also increases the confidence in peptide and protein assignments.

Amino Acid Sequence↗

Subcellular imaging mass spectrometry of brain tissue.

Imaging mass spectrometry provides both chemical information and the spatial distribution of each analyte detected. Here it is demonstrated how imaging mass spectrometry of tissue at subcellular resolution can be achieved by combining the high spatial resolution of secondary ion mass spectrometry (SIMS) with the sample preparation protocols of matrix-assisted laser desorption/ionization (MALDI). Despite mechanistic differences and sampling 10(5) times less material, matrix-enhanced (ME)-SIMS of tissue samples yields similar results to MALDI (up to m/z 2500), in agreement with previous studies on standard compounds. In this regard ME-SIMS represents an attractive alternative to polyatomic primary ions for increasing the molecular ion yield. ME-SIMS of whole organs and thin sections of the cerebral ganglia of Lymnaea stagnalis demonstrate the advantages of ME-SIMS for chemical imaging mass spectrometry. Subcellular distributions of cellular analytes are clearly obtained, and the matrix provides an in situ height map of the tissue, allowing the user to identify rapidly regions prone to topographical artifacts and to deconvolute topographical losses in mass resolution and signal-to-noise ratio.

Animals↗

High-spatial resolution mass spectrometric imaging of peptide and protein distributions on a surface.

For the first time macromolecular ion microscope images have been recorded using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Single-shot, mass-resolved images of the spatial distributions of intact peptide and protein ions over an area of 200 microm in diameter were obtained in less than 1 ms at a repetition rate of 12 Hz. The magnifying ion optics of the ion microscope allowed ion images to be obtained with a lateral resolution of 4 microm. These results prove the concept of high-resolution MALDI-MS imaging in microscope mode without the need for a tight laser focus and the accompanying sensitivity losses. The ion microscopy approach offers an improvement of several orders of magnitude in speed of acquisition compared to the conventional (microprobe) approach to MALDI-MS imaging.

Image Processing, Computer-Assisted↗

Electron capture dissociation at low temperatures reveals selective dissociations.

Electron capture dissociation at 86 K of the linear peptide Substance P produced just two backbone fragments, whereas at room temperature eight backbone fragments were formed. Similarly, with the cyclic peptide gramicidin S, just one backbone fragment was formed at 86 K but five at room temperature. The observation that some backbone scissions are active and others inactive, when all involve NC(alpha) cleavages and have a high rate constant, indicates that the more specific fragments at low temperatures reflects the reduced conformation heterogeneity at low temperatures. This is supported by reduced or inactive hydrogen loss, a channel that has previously been shown to be affected by conformation. The conclusion that the ECD fragments are a snapshot of the conformational (intramolecular solvation shell) heterogeneity helps explain how the relative intensities of ECD fragments can be different on different instrument and highlights the common theme in methodologies used to increase sequence coverage, namely an increase in the conformational heterogeneity of the precursor ion population.

Cold Temperature↗

Using matrix peaks to map topography: increased mass resolution and enhanced sensitivity in chemical imaging.

It is well known in secondary ion mass spectrometry (SIMS) that sample topography leads to decreased mass resolution. Specifically, the ion's time of flight is dependent on where it was generated. Here, using matrix-enhanced SIMS, it is demonstrated that, in addition to increasing the yield of intact pseudomolecular ions, the matrix allows the user to semiquantitatively record the topography of a sample. Through mapping the topography-related mass shifts of the matrix (which leads to decreased mass resolution), the analogous mass shifts of higher mass ions can be deconvoluted and higher resolution and greater sensitivity obtained. Furthermore, the semiquantitative topographical map obtained can be compared with any chemical images obtained, allowing the user to quickly ascertain whether local intensity maximums are due to topological features or represent genuine features of interest.

Journal Article↗

Effect of local matrix crystal variations in matrix-assisted ionization techniques for mass spectrometry.

Intense intact molecular ion signals have been obtained from phosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol, and phosphatidyiinositol using matrix-enhanced secondary ion mass spectrometry (ME-SIMS). It was found that the high-mass (m/z >500) regions of the ME-SIMS spectra closely resembled those obtained using matrix-assisted laser desorption/ionization (MALDI). Using high spatial resolution SIMS, a detailed investigation of dried-droplet samples was performed. Based on the detected Na+ and 2,5-DHB matrix signal intensities, different crystal types were distinguished, in addition to different sizes of crystals. Spatially mapping the pseudomolecular and fragment ions of the phospholipids revealed that the nature of the pseudomolecular ions formed, as well as the ratio of intact molecular to fragment ion, was dependent on the type and surface composition of the crystal. The observed chemical bias effects due to crystal heterogeneity and the resulting variation in desorption/ionization efficiency will complicate the interpretation of data obtained from matrix-assisted mass spectrometric (imaging) techniques and is an important factor in the "hot spot" phenomenon frequently encountered in MALDI experiments. In this respect, imaging SIMS was found to be a versatile tool to investigate the effects of the local physicochemical conditions on the detected molecular species.

Crystallization↗

Determination of the nature of naphthenic acids present in crude oils using nanospray Fourier transform ion cyclotron resonance mass spectrometry: the continued battle against corrosion.

Recent research has shown that the corrosivity of naphthenic acids is related to their molecular mass and that the "total acid number" (TAN), traditionally used as an indicator of the naphthenic acid content of an oil, is not as reliable as first believed. The presence of naphthenic acids in crude oils leads to the corrosion of oil refinery equipment, with the oil industry incurring costs that will ultimately be passed on to the consumer. With regard to these concerns, mass spectrometry has been increasingly applied to the investigation of the naphthenic acid content of crude oils. To ascertain the nature of the species present, however, it is necessary to utilize an ionization technique that does not result in fragmentation, ensuring the detection only of molecular species which provide useful information about the sample constitution. In the following investigation, negative ion mode nanospray Fourier transform ion cyclotron resonance (FTICR) mass spectrometry has been applied to the analysis of crude oil samples, providing insight into the different acidic species that were present. Use of the negative ion mode to allow the selective observation of the naphthenic acids and the inherent high mass accuracy and ultrahigh resolution of FTICR mass spectrometry ensure that this technique is very well suited to the characterization of naphthenic acids within a crude oil sample. Determination of the nature of the naphthenic acids present provides vital information, such as the acids' sizes and composition, which may be used in the battle against corrosion and also used to fingerprint samples from different oil fields.

Journal Article↗

Sustained off-resonance irradiation collision-induced dissociation of linear, substituted and cyclic polyesters using a 9.4 T Fourier transform ion cyclotron resonance mass spectrometer.

The fragment ions obtained from sustained off-resonance irradiation collision-induced dissociation of linear polyesters, substituted polyesters and cyclic polyesters have been characterized using a 9.4 T Fourier transform ion cyclotron resonance mass spectrometer. Charge-induced and charge-remote fragmentation channels, together with the participation of other nucleophilic groups, are proposed for the substituted polyesters. The linear polyesters were found to fragment at equivalent positions along the polymer chain whereas, under the experimental conditions employed, the cyclic polyester produced a single fragment.

Journal Article↗

Infrared mass spectrometric imaging below the diffraction limit.

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS)1 is an established technique for the analysis of biological macromolecules. Its relative insensitivity to pollutants makes MALDI-MS very suitable for the direct analysis of biological samples. As such, it has facilitated great advances in the field of biomolecular imaging mass spectrometry. Traditionally, MALDI-MS imaging is performed in a scanning microprobe methodology.(2-4) However, in a recent study we have demonstrated an alternative methodology; the so-called microscope mode,(5) where the requirement for a highly focused ionization beam is removed. Spatial details from within the desorption area are conserved during the flight of the ions through the mass analyzer, and a magnified ion image is projected onto a 2D-detector. In this paper, we demonstrate how imaging mass spectrometry benefits from the microscope mode approach. For the first time, high-lateral resolution ion images were recorded using infrared MALDI at 2.94 microm wavelength. The ion optical resolution achieved was well below the theoretical limit of (light-) diffraction for the setup used, which is impossible to achieve in the conventional scanning microprobe approach.

Infrared Rays↗