Region of interest reconstruction from truncated data in circular cone-beam CT.

The circular scanning trajectory is one of the most widely adopted data-acquisition configurations in computed tomography (CT). The Feldkamp, Davis, Kress (FDK) algorithm and its various modifications have been developed for reconstructing approximately three-dimensional images from circular cone-beam data. When data contain transverse truncations, however, these algorithms may reconstruct images with significant truncation artifacts. It is of practical significance to develop algorithms that can reconstruct region-of-interest (ROI) images from truncated circular cone-beam data that are free of truncation artifacts and that have an accuracy comparable to that obtained from nontruncated cone-beam data. In this work, we have investigated and developed a backprojection-filtration (BPF)-based algorithm for ROI-image reconstruction from circular cone-beam data containing transverse truncations. Furthermore, we have developed a weighted BPF algorithm to exploit "redundant" information in data for improving image quality. In an effort to validate and evaluate the proposed BPF algorithms for circular cone-beam CT, we have performed numerical studies by using both computer-simulation data and experimental data acquired with a radiotherapy cone-beam CT system. Quantitative results in these studies demonstrate that the proposed BPF algorithms for circular cone-beam CT can reconstruct ROI images free of truncation artifacts.

Algorithms↗

Region-of-interest reconstruction of motion-contaminated data using a weighted backprojection filtration algorithm.

The recently developed weighted backprojection filtration (WBPF) algorithm using data redundancy has capabilities that make this algorithm an attractive candidate for reconstructing images from motion-contaminated projection data. First, the WBPF algorithm is capable of reconstructing region-of-interest (ROI) images from reduced-scan fan-beam data, which have less data than the short-scan data required to reconstruct the entire field of view (FOV). Second, this algorithm can reconstruct ROI images from truncated data. Using phantom simulation studies, we demonstrate how these unique capabilities can be exploited to reduce the amount of motion-contaminated data used for reconstruction. In particular, we use examples from cardiac imaging to illustrate how off-center phantom positioning combined with phase-interval ROI reconstruction can result in the suppression of motion artifacts. In terms of temporal resolution, reduced-scan reconstruction with 45% of a full-scan dataset can be used to improve the temporal resolution of a short-scan reconstruction by 25.8% if ungated data are used. For data gated at 66 beats per minute, reduced-scan reconstruction with 45% of a full-scan dataset can be used to improve the temporal resolution of a short-scan reconstruction by 7.9%. As a result of our studies, we believe that the WBPF algorithm demonstrates the potential for reconstructing quality ROI images from motion-contaminated fan-beam data.

Algorithms↗

A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy.

PURPOSE: To develop a hybrid approach to reduce computed tomography (CT) metal artifacts caused by the Fletcher-Suit applicator. METHODS AND MATERIALS: Using the acquired raw projection data, the hybrid algorithm determines the separate contributions from the metal and non-metal objects. Next, reconstructions of metal and non-metal images are separately obtained from their estimated projections. A final image is formed by appropriately combining the individual images. Phantom and patient data are used to evaluate the performance of this method. RESULTS: CT images reconstructed by use of the standard filtered-backprojection (FBP) algorithm contain significant artifacts even for small metal objects. However, images reconstructed using the hybrid algorithm contain virtually no artifacts. For metal objects with complex structures, the hybrid algorithm can also yield images containing fewer severe streak artifacts than those reconstructed using the FBP algorithm alone. CONCLUSIONS: These studies demonstrate that the hybrid approach can effectively reduce CT metal artifacts caused by the Fletcher-Suit applicator.

Algorithms↗

Spatial-resolution enhancement in computed tomography.

We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, however, require new detectors and X-ray source nor alter the relative geometry between the detector and the X-ray source. By effectively reducing the distance of the COR to the X-ray source, the asymmetric configuration can increase the effective sampling density in projection data without reducing the size of the field of view (FOV). The proposed algorithm, on the other hand, can reconstruct images directly from data acquired with this asymmetric configuration. We performed numerical studies to demonstrate and validate the proposed acquisition/reconstruction approach. Results in these studies confirm that the proposed approach can lead to enhanced spatial resolution in reconstructed images. The proposed acquisition/reconstruction approach may find applications in micro-CT and industrial CT in which the CORs may be changed.

Algorithms↗

A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans.

A circular scanning trajectory is and will likely remain a popular choice of trajectory in computed tomography (CT) imaging because it is easy to implement and control. Filtered-backprojection (FBP)-based algorithms have been developed previously for approximate and exact reconstruction of the entire image or a region of interest within the image in circular cone-beam and fan-beam cases. Recently, we have developed a 3D FBP-based algorithm for image reconstruction on PI-line segments in a helical cone-beam scan. In this work, we demonstrated that the 3D FBP-based algorithm indeed provided a rather general formulation for image reconstruction from divergent projections (such as cone-beam and fan-beam projections). On the basis of this formulation we derived new approximate or exact algorithms for image reconstruction in circular cone-beam or fan-beam scans, which can be interpreted as special cases of the helical scan. Existing algorithms corresponding to the derived algorithms were identified. We also performed a preliminary numerical study to verify our theoretical results in each of the cases. The results in the work can readily be generalized to other non-circular trajectories.

Algorithms↗

Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography.

In computed tomography (CT), the fan-beam filtered backprojection (FFBP) algorithm is used widely for image reconstruction. It is known that the FFBP algorithm can significantly amplify data noise and aliasing artifacts in situations where the focal lengths are comparable to or smaller than the size of the field of measurement (FOM). In this work, we propose an algorithm that is less susceptible to data noise, aliasing, and other data inconsistencies than is the FFBP algorithm while retaining the favorable resolution properties of the FFBP algorithm. In an attempt to evaluate the noise properties in reconstructed images, we derive analytic expressions for image variances obtained by use of the FFBP algorithm and the proposed algorithm. Computer simulation studies are conducted for quantitative evaluation of the spatial resolution and noise properties of images reconstructed by use of the algorithms. Numerical results of these studies confirm the favorable spatial resolution and noise properties of the proposed algorithm and verify the validity of the theoretically predicted image variances. The proposed algorithm and the derived analytic expressions for image variances can have practical implications for both estimation and detection/classification tasks making use of CT images, and they can readily be generalized to other fan-beam geometries.

Algorithms↗

Half-scan fan-beam computed tomography with improved noise and resolution properties.

Half-scan strategy can be used for reducing scanning time and radiation dose delivered to the patient in fan-beam computed tomography (CT). In helical CT, the data weighting/interpolation functions are often devised based upon half-scan configurations. The half-scan fan-beam filtered backprojection (FFBP) algorithm is generally used for image reconstruction from half-scan data. It can, however, be susceptible to sample aliasing and data noise for configurations with short focal lengths and/or large fan-angles, leading to nonuniform resolution and noise properties in reconstructed images. Uniform resolution and noise properties are generally desired because they may lead to an increased utility of reconstructed images in estimation and/or detection/classification tasks. In this work, we propose an algorithm for reconstruction of images with uniform noise and resolution properties in half-scan CT. In an attempt to evaluate the image-noise properties, we derive analytic expressions for image variances obtained by use of the half-scan algorithms. We also perform numerical studies to assess quantitatively the resolution and noise properties of the algorithms. The results in these studies confirm that the proposed algorithm yields images with more uniform spatial resolution and with lower and more uniform noise levels than does the half-scan FFBP algorithm. Empirical results obtained in noise studies also verify the validity of the derived expressions for image variances. The proposed algorithm would be particularly useful for image reconstruction from data acquired by use of configurations with short focal lengths and large field of measurement, which may be encountered in compact micro-CT and radiation therapeutic CT applications. The analytic results of the image-noise properties can be used for image-quality assessment in detection/classification tasks by use of model-observers.

Algorithms↗