PubMed Health⌕ Search

Biomedical subjects

Lin Xuan

Publications and source records attributed to Lin Xuan.

2 recordsLinked to original sources

Determination of trace silver by solid substrate-room temperature phosphorescence quenching method based on double catalytic system of meta-nitrophenyfluorone-polyoxyethylene-chromium-potassium bromate-beta-cyclodextrin.

A new solid substrate-room temperature phosphorescence (SS-RTP) quenching method for the determination of trace silver has been established. It is based on the fact that when using Mg(2+) as ion perturber and beta-CD as surfactant, the system of meta-nitrophenyfluorone (R)-polyoxyethylene-Cr(III) can emit strong and stable room temperature phosphorescence signal on filter paper whose surface is modified by polyvinyl alcohol (PVA)-H(3)BO(3)-NaOH. Ag(I) can catalyze KBrO(3) oxidizing R-PEO-Cr(III) system which causes the quenching of SS-RTP. The reducing value of phosphorescence intensity (DeltaI(p)) is directly proportional to the concentration of Ag(I) in the range of 3.2-160 ag spot(-1) (corresponding concentration: 2.43 fg ml(-1), the sample volume: 0.40 microl spot(-1)) with a detection limit (LD) of 0.97 ag spot(-1). The regression equation of working curve can be expressed as DeltaI(p)=13.92+0.3089m(Ag)+ (ag spot(-1)) (r=0.9983, n=6). This method has many advantages, such as a wide linear dynamic range, high sensitivity, good repeatability and selectivity. It has been applied to the determination of trace silver in real samples with satisfactory results. What is more, the mechanism of SS-RTP quenching method based on Ag(I) catalyzing KBrO(3) oxidizing meta-nitrophenyfluorone has also been discussed.

Catalysis↗

Determination of trace aluminum by fluorescence quenching method based on catalysis of potassium chlorate oxidizing alizarin red.

A new method for the determination of trace aluminum has been proposed. It is based on the fact that alizarin red can emit strong and stable fluorescence at 80 degrees C for 30 min and Al(3+) can effectively catalyze potassium chlorate oxidizing alizarin red to form non-fluorescence complex which cause the fluorescence quenching. The linear dynamic range of this method is 0.040-4.00 ngl(-1) with a detection limit of 5.3 pgl(-1). The regression equation can be expressed as DeltaI(f)=8.731+21.73c(Al(3+)) (ngl(-1)), with the correlation coefficient r=0.9992 (n=6). This sensitive, rapid and accurate method has been applied to the determination of trace aluminum(III) in human hair and tea samples successfully. What is more, the mechanism of catalyzing potassium chlorate oxidizing alizarin red by the fluorescence quenching method is also discussed.

Aluminum↗