Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography.

PURPOSE: To compare the ability of optical coherence tomography retinal nerve fiber layer (RNFL), optic nerve head, and macular thickness parameters to differentiate between healthy eyes and eyes with glaucomatous visual field loss. DESIGN: Observational case-control study. METHODS: Eighty-eight patients with glaucoma and 78 healthy subjects were included. All patients underwent ONH, RNFL thickness, and macular thickness scans with Stratus OCT during the same visit. ROC curves and sensitivities at fixed specificities were calculated for each parameter. A discriminant analysis was performed to develop a linear discriminant function designed to identify and combine the best parameters. This LDF was subsequently tested on an independent sample consisting of 63 eyes of 63 subjects (27 glaucomatous and 36 healthy individuals) from a different geographic area. RESULTS: No statistically significant difference was found between the areas under the ROC curves (AUC) for the RNFL thickness parameter with the largest AUC (inferior thickness, AUC = 0.91) and the ONH parameter with largest AUC (cup/disk area ratio, AUC = 0.88) (P = .28). The RNFL parameter inferior thickness had a significantly larger AUC than the macular thickness parameter with largest AUC (inferior outer macular thickness, AUC = 0.81) (P = .004). A combination of selected RNFL and ONH parameters resulted in the best classification function for glaucoma detection with an AUC of 0.97 when applied to the independent sample. CONCLUSIONS: RNFL and ONH measurements had the best discriminating performance among the several Stratus OCT parameters. A combination of ONH and RNFL parameters improved the diagnostic accuracy for glaucoma detection using this instrument.

Aged↗

Use of progressive glaucomatous optic disk change as the reference standard for evaluation of diagnostic tests in glaucoma.

PURPOSE: Progressive change in optic disk appearance has been suggested as the best available reference standard for glaucoma diagnosis. We evaluated the accuracy of scanning laser polarimetry (SLP) with variable corneal compensation to discriminate patients with documented progressive optic disk change from healthy subjects. DESIGN: Observational case-control study. METHODS: Glaucoma patients with documented evidence of progressive optic disk change as assessed by stereoscopic photographs were selected. Healthy control subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC scanning laser polarimeter. Receiver-operating characteristic (ROC) curves, sensitivities at fixed specificities, and likelihood ratios were calculated. RESULTS: Sixty-five eyes were healthy control patients. Seventy-one eyes had progressive optic disk change, of which 41 (58%) had abnormal visual field tests closest to the imaging date (perimetric glaucomatous optic neuropathy [GON]), and 30 (42%) eyes had normal visual fields (preperimetric GON). The GDx VCC parameter nerve fiber indicator performed best for discrimination between perimetric GON and normal eyes (AUC = 0.94; sensitivity = 93% for specificity > or =80%) as well as for the discrimination between preperimetric GON and normal eyes (AUC = 0.89; sensitivity = 83% for specificity > or =80%). CONCLUSION: SLP differentiated patients with documented progressive optic disk change from normal subjects and detected abnormalities in patients with confirmed diagnosis of preperimetric GON, suggesting that it may be useful for early glaucoma diagnosis. We suggest that progressive optic disk change should be used in the evaluation of diagnostic accuracy of imaging instruments for glaucoma.

Aged↗

Scanning laser polarimetry retinal nerve fiber layer thickness measurements after LASIK.

PURPOSE: To compare retinal nerve fiber layer (RNFL) thickness measurements before and after LASIK. DESIGN: Cohort study. PARTICIPANTS: Twenty participants undergoing LASIK and 14 normal controls. METHODS: Retinal nerve fiber layer thickness was measured before LASIK and approximately 3 months after surgery in one eye each of 20 patients using a scanning laser polarimeter (GDx Nerve Fiber Analyzer) with fixed corneal compensation (FCC), one with variable corneal compensation (GDx VCC), and optical coherence tomography (OCT). Fourteen normal controls also were tested at baseline and approximately 3 months later. MAIN OUTCOME MEASURES: Retinal nerve fiber layer thicknesses measured with the GDx FCC, GDx VCC, and OCT. RESULTS: At baseline, mean (95% confidence interval [CI]) RNFL thicknesses for the GDx FCC, GDx VCC, and OCT were 78.1 microm (72.2-83.9), 54.3 microm (52.7-56.0), and 96.8 microm (93.2-100.5), respectively. In both LASIK and control groups, there were no significant changes between baseline and follow-up examinations in GDx VCC and OCT RNFL thickness measurements globally or in the superior and inferior quadrants (mean change, <5 microm for each instrument). In the control group, there also was no significant change in GDx FCC measurements between baseline and follow-up. In LASIK patients, significant reductions were observed in GDx FCC RNFL measurements. Average absolute values of the mean (95% CI) change in thickness were 12.4 microm (7.7-17.2), 15.3 microm (9.6-20.9), and 12.9 microm (7.6-18.1) for GDx FCC RNFL measurements superiorly, inferiorly, and globally, respectively (all Ps < or = 0.001). CONCLUSIONS: LASIK does not seem to change RNFL thickness. Reduction in GDx FCC RNFL thickness measurements after LASIK is a measurement artifact and is most likely due to erroneous compensation for corneal birefringence. With scanning laser polarimetry, it is mandatory to compensate individually for change in corneal birefringence after LASIK to ensure accurate RNFL assessment.

Adult↗

Relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertensive patients.

PURPOSE: To examine the relationship between retinal nerve fiber layer (RNFL) measurements obtained using scanning laser polarimetry with variable corneal compensation and corneal thickness measurements in ocular hypertension (OHT) patients. DESIGN: Observational cross-sectional study. SUBJECTS: The study included 1 eye each from 44 OHT patients and 48 healthy subjects, all of similar age. All subjects had normal optic discs and normal standard automated perimetry (SAP) visual fields. Ocular hypertension patients had intraocular pressure (IOP) measurements higher than 22 mmHg. METHODS: All patients underwent imaging with the GDx VCC (Laser Diagnostic Technologies, Inc., San Diego, CA) scanning laser polarimeter. We examined the relationship between GDx VCC RNFL measurements and central corneal thickness, a risk factor for development of visual field loss among OHT patients. We also examined the relationship of GDx VCC measurements and age, IOP, SAP pattern standard deviation, and vertical cup-to-disc ratio. MAIN OUTCOME MEASURES: Central corneal thickness (CCT) and GDx VCC RNFL thickness parameters. RESULTS: Central corneal thickness measurements in OHT patients were significantly higher than those in healthy subjects (575+/-30 microm vs. 555+/-32 microm; P = 0.002). Higher GDx VCC parameter nerve fiber indicator (NFI) scores, indicating thinner RNFL, were correlated significantly with thinner CCT measurements in OHT patients (r = -0.502; P = 0.001). Ocular hypertension patients with thinner corneas (n = 22; mean CCT, 553+/-21 microm) had significantly higher NFI scores than OHT patients with thicker corneas (n = 22; mean CCT, 598+/-18 microm) and healthy control subjects (NFI mean +/- standard deviation, 26.9+/-9.5, 20.7+/-9.8, and 19.7+/-7.0, respectively; P = 0.004, analysis of variance). The NFI values were not significantly different between OHT patients with thicker corneas and healthy subjects. In multivariate analysis, only age and CCT measurement were associated significantly with GDx VCC RNFL measurements in OHT eyes. CONCLUSIONS: Ocular hypertension patients with thinner corneas had significantly thinner RNFL than OHT patients with thicker corneas and healthy control subjects. These findings support the notion that RNFL defects as assessed by the GDx VCC may represent early glaucomatous damage in OHT eyes.

Aged↗

Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments.

PURPOSE: To compare retinal nerve fiber layer (RNFL) measurements between two ocular coherence tomography (OCT) instruments (OCT 2000 and Stratus OCT; Carl Zeiss Meditec, Dublin, CA) and compare their diagnostic precision. METHODS: One hundred thirty-nine consecutive subjects were imaged (3 x 3.4-mm diameter circular scans) on the same day with each instrument. Thirty-five patients were excluded due to poor-quality images. RNFL thicknesses measured by the two instruments were compared, and receiver operating characteristic (ROC) curves were used to determine diagnostic precision. RESULTS: A randomly selected eye of each of 104 participants (28 with open-angle glaucoma, 40 with suspected glaucoma, and 36 healthy subjects) was analyzed. RNFL thickness measurements generally were thicker with OCT 2000 than with Stratus OCT. The difference in global RNFL thickness between instruments was within 20 microm in 66 (65%) of subjects and within 10 microm (the instrument's limit of resolution) in 25 (25%) subjects. Application of a correction factor to OCT 2000 measurements predicted Stratus OCT RNFL thickness within 10 microm of the observed measurement in 75% of the eyes. For both instruments, highest ROC curve areas (better discrimination between glaucomatous and normal eyes) were found in the inferior sector. Discrimination using global RNFL thickness was better with Stratus OCT than OCT 2000 (P = 0.043). CONCLUSIONS: RNFL thickness measurements measured by OCT 2000 can be approximated to measurements made by Stratus OCT using correction factors calculated by this study. However, there remains considerable variability that exceeds the limits of resolution afforded by the instruments themselves. Therefore comparisons between instruments using these approximations should be interpreted with caution.

Aged↗

Relevance vector machine and support vector machine classifier analysis of scanning laser polarimetry retinal nerve fiber layer measurements.

PURPOSE: To classify healthy and glaucomatous eyes using relevance vector machine (RVM) and support vector machine (SVM) learning classifiers trained on retinal nerve fiber layer (RNFL) thickness measurements obtained by scanning laser polarimetry (SLP). METHODS: Seventy-two eyes of 72 healthy control subjects (average age = 64.3 +/- 8.8 years, visual field mean deviation = -0.71 +/- 1.2 dB) and 92 eyes of 92 patients with glaucoma (average age = 66.9 +/- 8.9 years, visual field mean deviation = -5.32 +/- 4.0 dB) were imaged with SLP with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, San Diego, CA). RVM and SVM learning classifiers were trained and tested on SLP-determined RNFL thickness measurements from 14 standard parameters and 64 sectors (approximately 5.6 degrees each) obtained in the circumpapillary area under the instrument-defined measurement ellipse (total 78 parameters). Ten-fold cross-validation was used to train and test RVM and SVM classifiers on unique subsets of the full 164-eye data set and areas under the receiver operating characteristic (AUROC) curve for the classification of eyes in the test set were generated. AUROC curve results from RVM and SVM were compared to those for 14 SLP software-generated global and regional RNFL thickness parameters. Also reported was the AUROC curve for the GDx VCC software-generated nerve fiber indicator (NFI). RESULTS: The AUROC curves for RVM and SVM were 0.90 and 0.91, respectively, and increased to 0.93 and 0.94 when the training sets were optimized with sequential forward and backward selection (resulting in reduced dimensional data sets). AUROC curves for optimized RVM and SVM were significantly larger than those for all individual SLP parameters. The AUROC curve for the NFI was 0.87. CONCLUSIONS: Results from RVM and SVM trained on SLP RNFL thickness measurements are similar and provide accurate classification of glaucomatous and healthy eyes. RVM may be preferable to SVM, because it provides a Bayesian-derived probability of glaucoma as an output. These results suggest that these machine learning classifiers show good potential for glaucoma diagnosis.

Aged↗

Unsupervised machine learning with independent component analysis to identify areas of progression in glaucomatous visual fields.

PURPOSE: To determine whether a variational Bayesian independent component analysis mixture model (vB-ICA-mm), a form of unsupervised machine learning, can be used to identify and quantify areas of progression in standard automated perimetry fields. METHODS: In an earlier study, it was shown that a model using vB-ICA-mm can separate normal fields from fields with six different patterns of visual field loss related to glaucomatous optic neuropathy (GON) along maximally independent axes. In the present study, an independent group of 191 patient eyes (66 with ocular hypertension (OHT), 12 with suspected glaucoma by field, 61 with suspected glaucoma by disc, and 52 with glaucoma) with five or more standard visual fields under observation for a mean of 6.24 +/- 2.65 years and 8.11 +/- 2.42 visual fields were evaluated with the vB-ICA-mm. In addition, eyes with progressive GON (PGON) were identified (n = 39). Each participant had a series of fields tested, with each field entered independently and placed along the axes of the previously developed model. This allowed change in one pattern of visual field defect (along one axis) to be assessed relative to results other areas of that same field (no change along other axes). Progression was based on a slope falling outside the 5th and the 95th percentile limits of all slopes, with at least two axes not showing such a deviation in a given individual's series of fields. Fields were also scored using Advanced Glaucoma Intervention Study (AGIS) and the Early Manifest Glaucoma Treatment Trial (EMGT) criteria. RESULTS: Thirty-two of 191 eyes progressed on vB-ICA-mm by this definition. Of the 32, 22 had field loss at baseline, 7 had only GON, 3 were OHTs and 12 were from the 39 eyes (31%) with PGON. The vB-ICA-mm identified a higher percentage of progressing eyes in each diagnostic category than did AGIS or and the EMGT. CONCLUSIONS: The vB-ICA-mm can quantitatively identify progression in eyes with glaucoma by evaluating change in one or more patterns of the visual field loss while other areas or patterns remain stable. This may enable each eye to contribute to the determination of whether change is caused by true progression or by variability.

Adult↗

Racial differences in optic disc topography: baseline results from the confocal scanning laser ophthalmoscopy ancillary study to the ocular hypertension treatment study.

OBJECTIVE: To examine racial differences in optic disc topography among ocular hypertensive participants in the Ocular Hypertension Treatment Study. METHODS: Four hundred thirty-nine participants from 7 Ocular Hypertension Treatment Study centers who had good-quality baseline images obtained using a quantitative 3-dimensional confocal scanning laser ophthalmoscope, the Heidelberg Retina Tomograph (Heidelberg Engineering, Dossenheim, Germany), were included in this study. The first 10 degrees- or 15 degrees-field of view mean topographic image acquired was included in all analyses. Differences in Heidelberg Retina Tomograph topographic optic disc parameter measurements by self-identified race were assessed using a mixed-effects linear model to control for confounders and for the use of both eyes in the model. RESULTS: By self-attribution, 74 (17%) of the 439 participants were of African origin, 329 (75%) were white, 24 (5%) were Hispanic, and 12 (3%) were Native American, Native Alaskan, Asian, Pacific Islander, or unknown. The African American participants had statistically significantly (P<.001) larger mean (SD) optic disc areas than the other participants, 2.17 (0.41) mm(2) vs 1.87 (0.38) mm(2), respectively. African American participants had a larger cup area, cup volume, cup depth, neuroretinal rim area, rim volume, and smaller rim-optic disc area ratios than the other participants. No difference between African American and the other participants was found for cup shape and retinal nerve fiber layer thickness. After controlling for optic disc area, none of the differences between African American and the other participants found in the univariate analysis remained statistically significant (P>.10). CONCLUSIONS: This study demonstrated in a large cohort of subjects with ocular hypertension, that African Americans have significantly larger optic discs, optic cups, neuroretinal rims, and cup-disc ratios than other racial groups. Furthermore, this study found that differences in topographic optic disc parameters between African Americans with ocular hypertension and other racial groups are largely explained by the larger optic disc area in the African Americans. These results highlight the need to consider race and optic disc size when evaluating the appearance of the optic disc in glaucoma.

Antihypertensive Agents↗

Comparison of scanning laser polarimetry using variable corneal compensation and retinal nerve fiber layer photography for detection of glaucoma.

OBJECTIVE: To compare retinal nerve fiber layer (RNFL) measurements obtained with scanning laser polarimetry (SLP) using variable corneal polarization compensation with standard red-free photography for detection of RNFL damage in glaucoma. METHODS: This observational, cross-sectional study included 1 eye of each of 42 patients with open-angle glaucoma, 32 patients suspected of having glaucoma, and 40 healthy subjects. The RNFL measurements using SLP with variable corneal compensation were obtained within 3 months of red-free photographs. Two independent observers graded RNFL photographs using a standardized protocol. Superior and inferior hemiretinas were scored separately, and a global score was obtained by averaging scores from each hemiretina. MAIN OUTCOME MEASURES: The RNFL photography scores were compared with RNFL thickness measurements obtained with SLP. The receiver operating characteristic (ROC) curves were constructed to assess the abilities of the different methods to differentiate glaucoma patients from healthy subjects. RESULTS: The RNFL thickness decreased with increased RNFL damage as assessed by photographs in both hemiretinas (R(2) = 15%-47%). The area under the ROC curve for the best SLP parameter, Nerve Fiber Indicator, was significantly greater than the area under the ROC curve for the global RNFL photography score (0.91 vs 0.84, P =.03). CONCLUSIONS: A moderate correlation was found between RNFL thickness measurements obtained with SLP and RNFL scores from red-free photographs. Compared with semiquantitative RNFL photography scores, the best SLP parameter had a higher diagnostic accuracy to separate glaucoma patients from healthy subjects.

Aged↗

Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma.

OBJECTIVE: To compare the abilities of current commercially available versions of 3 optical imaging techniques: scanning laser polarimetry with variable corneal compensation (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]), and optical coherence tomography (Stratus OCT) to discriminate between healthy eyes and eyes with glaucomatous visual field loss. METHODS: We included 107 patients with glaucomatous visual field loss and 76 healthy subjects of a similar age. All individuals underwent imaging with a GDx VCC, HRT II, and fast retinal nerve fiber layer scan with the Stratus OCT as well as visual field testing within a 6-month period. Receiver operating characteristic curves and sensitivities at fixed specificities (80% and 95%) were calculated for parameters reported as continuous variables. Diagnostic categorization (outside normal limits, borderline, or within normal limits) provided by each instrument after comparison with its respective normative database was also evaluated, and likelihood ratios were reported. Agreement on categorization between methods (weighted kappa) was assessed. RESULTS: After the exclusion of subjects with unacceptable images, the final study sample included 141 eyes of 141 subjects (75 with glaucoma and 66 healthy control subjects). Mean +/- SD mean deviation of the visual field test result for patients with glaucoma was -4.87 +/- 3.9 dB, and 70% of these patients had early glaucomatous visual field damage. No statistically significant difference was found between the areas under the receiver operating characteristic curves (AUCs) for the best parameters from the GDx VCC (nerve fiber indicator, AUC = 0.91), Stratus OCT (retinal nerve fiber layer inferior thickness, AUC = 0.92), and HRT II (linear discriminant function, AUC = 0.86). Abnormal results for each of the instruments, after comparison with their normative databases, were associated with strong positive likelihood ratios. Chance-corrected agreement (weighted kappa) among the 3 instruments ranged from moderate to substantial (0.50-0.72). CONCLUSIONS: The AUCs and the sensitivities at high specificities were similar among the best parameters from each instrument. Abnormal results (as compared with each instrument's normative database) were associated with high likelihood ratios and large effects on posttest probabilities of having glaucomatous visual field loss. Calculation of likelihood ratios may provide additional information to assist the clinician in diagnosing glaucoma with these instruments.

Aged↗

The confocal scanning laser ophthalmoscopy ancillary study to the ocular hypertension treatment study: study design and baseline factors.

PURPOSE: To describe the study design of the Confocal Scanning Laser Ophthalmoscopy (CSLO) Ancillary Study to the Ocular Hypertension Treatment Study (OHTS) and to examine the associations between optic disk topography, and baseline demographic, clinical, and ocular factors at study entry. DESIGN: A randomized clinical trial. METHODS: Participants in this ancillary study were recruited from seven of the 22 OHTS clinical centers. Each participant completed imaging annually using a CSLO, the Heidelberg Retina Tomograph (HRT). Associations between HRT topographic optic disk measurements and intraocular pressure (IOP), baseline photographic estimates of horizontal and vertical cup-to-disk diameter ratios by the OHTS Optic Disk Reading Center, baseline visual field indices, and demographic and clinical factors were assessed using linear mixed effects models. RESULTS: Four hundred thirty-nine participants had good quality images and were included in this baseline analysis. No associations between HRT topographic optic disk measurements and diabetes, systemic hypertension, cardiovascular disease, IOP, or visual function were found. The HRT topographic optic disk measurements were associated with baseline stereophotographic estimates of horizontal and vertical cup-to-disk diameter ratios. The strongest associations were found between stereophotographic assessment of horizontal and vertical cup-to-disk diameter ratios, and HRT cup-to-disk area ratio (r =.85 and.84, respectively), rim-to-disk area ratio (r = -.85 and -.84, respectively), mean cup depth (r =.84 and.83, respectively), and cup area (r =.83 and.80, respectively). After adjusting for optic disk area, all HRT topographic optic disk measurements remained associated with stereophotographic assessment of horizontal and vertical cup-to-disk diameter ratios. CONCLUSIONS: The CSLO ancillary study to the OHTS is the first multicenter clinical trial to use CSLO imaging to monitor changes in the optic disk. At study entry, HRT topographic measurements corresponded well with both horizontal and vertical stereophotographic-based estimates of cup-to-disk diameter ratio in ocular hypertensive participants.

Female↗

Corneal changes after laser in situ keratomileusis: measurement of corneal polarization magnitude and axis.

PURPOSE: Laser in situ keratomileusis (LASIK) involves ablation of the corneal stroma, which may induce a change in birefringence. The purpose of this study was to determine the effect of LASIK on corneal birefringence by measuring corneal polarization magnitude (CPM) and axis (CPA). STUDY DESIGN: Cohort study. METHODS: In this prospective study, we measured the change in CPM and CPA before and after LASIK with a scanning laser polarimeter ([SLP] GDx-VCC; Laser Diagnostic Technologies, San Diego, California). Scans were completed on 23 subjects before and 3 months after LASIK. 14 normal controls were tested twice during the same time interval. Change in CPM, CPA, corneal thickness, and corneal curvature measurements were compared between LASIK and normal subjects. RESULTS: At baseline, the mean (95% confidence interval) values of CPM, CPA, corneal thickness, and corneal curvature measurements of the total population (n = 37) were 41.6 nm (36.6, 46.5); 31.5 degrees (25.7, 37.3); 548.4 microm (540.0, 556.7); and 7.6 mm (7.5, 7.7), respectively. There were no significant differences in baseline values between normal and LASIK subjects. The reproducibility, measured as the average standard deviation of CPM and CPA measurements in 30 normal control eyes, was 1.95 nm (1.43, 2.48) and 1.69 degrees (0.92, 2.46), respectively. Mean CPA, corneal thickness, and corneal curvature measurements were significantly different in patients after LASIK (all P <.0001). Mean absolute values of the change in both CPM and CPA were significantly greater in LASIK patients (4.8 nm [3.3, 6.4], and 10.4 degrees [6.8, 14.1], respectively) than in normal subjects (2.43 nm [1.53, 3.33], and 1.64 degrees [1.15, 2.14], respectively; both P < or =.05). The absolute value of change in CPA was linearly associated with the absolute value of change in both corneal thickness (R(2) = 0.46) and corneal curvature (R(2) = 0.44). CONCLUSIONS: LASIK causes a measurable change in corneal birefringence as measured by the CPM and CPA that may be related to loss of corneal tissue. Comparison of SLP measurements before and after LASIK requires eye-specific compensation to adjust for the change in corneal birefringence.

Adult↗

Retinal nerve fiber layer thickness measurements with scanning laser polarimetry predict glaucomatous visual field loss.

PURPOSE: To assess whether baseline retinal nerve fiber layer (RNFL) measurements obtained with a scanning laser polarimeter, the GDx Nerve Fiber Analyzer, (Laser Diagnostic Technologies Inc., San Diego, California) are predictive of development of repeatable glaucomatous visual field damage in glaucoma suspect eyes. DESIGN: Cohort study. METHODS: Participants were recruited from the UCSD longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). One eye from each of 160 glaucoma suspects with normal standard automated perimetry (SAP) visual fields at baseline was studied. Study eyes were divided into convert and nonconvert groups based on the development of three consecutive glaucomatous visual fields during follow-up. SLP parameters, IOP, vertical cup disk ratio, stereophotograph assessment as glaucoma or normal, corneal thickness, and visual field indices were included in univariate and multivariate Cox proportional hazards models to determine which SLP RNFL and ocular parameters were predictive of visual field conversion. RESULTS: Sixteen (10%) eyes developed repeatable visual field damage (converts) and 144 (90%) did not (nonconverts). Mean (95%CI) follow-up time until visual field conversion for convert eyes was 2.7 (1.7, 3.6) years. Mean total follow-up of nonconvert eyes was 3.8 (3.5, 4.1) years. Four out of thirteen examined baseline SLP parameters and baseline SAP Mean Deviation (MD), SAP Pattern Standard Deviation (PSD), and glaucomatous stereophotograph assessment were significant univariate predictors of visual field conversion. In multivariate models adjusted for age, IOP and CCT, SLP parameters inferior ratio, ellipse modulation, and UCSD linear discriminant function (LDF) were significant predictors of visual field conversion. When SAP PSD and stereophotograph assessment were also included in the multivariate model inferior ratio and UCSD LDF remained independently predictive of visual field loss. CONCLUSIONS: Thinner baseline SLP RNFL measurements were independent predictors of visual field damage. In addition to thinner SLP RNFL measurements, higher baseline SAP PSD, and baseline glaucomatous stereophotograph assessment each contributed to an increased risk of the development of abnormal visual fields in glaucoma suspect patients. SLP RNFL measurements were independently predictive of future visual loss even when age, IOP, CCT, vertical cup disk ratio, and SAP PSD were included in the model.

Aged↗

Short-wavelength automated perimetry results are correlated with optical coherence tomography retinal nerve fiber layer thickness measurements in glaucomatous eyes.

PURPOSE: To determine the relationship between retinal nerve fiber layer (RNFL) thickness measured using optical coherence tomography (OCT) and short wavelength-sensitive visual function measured using short-wavelength automated perimetry (SWAP). DESIGN: Retrospective observational case series. METHODS: Subjects were recruited from the longitudinal University of California, San Diego, Diagnostic Innovations in Glaucoma Study and included 29 glaucoma patients with OCT imaging and reliable SWAP visual field (VF) testing within a 6-month window. MAIN OUTCOME MEASURES: Correlations between deviation from normal (thinner than 97.5% of normal) RNFL measurements taken at 30 degrees sectors (12 sectors described as clock hours) and SWAP average pattern deviation within 21 VF zones were determined. The number of OCT-measured RNFL sectors outside of normal limits and the number of VF zones outside of normal limits also were compared. RESULTS: The OCT nerve fiber layer thickness was outside of the normal limits in at least 1 sector in 26 (89.6%) patients. Twenty-eight (96.5%) patients had at least 1 SWAP VF zone outside of normal limits. Optical coherence tomography sectors 6-o'clock, 7-o'clock, and 8-o'clock (inferior and inferotemporal) and SWAP VF zones 13, 14, and 16 (superior hemifield central and arcuate areas) were the most frequently damaged. In general, the strongest R2 associations were between inferior and inferior temporal RNFL sectors (e.g., 6-o'clock, 7-o'clock) and superior nasal/arcuate VF zones (e.g., zones 13, 14, 15) and between superior and superior temporal RNFL sectors (e.g., 12-o'clock, 11-o'clock) and inferior central and arcuate VF zones (e.g., zones 5, 6, 7) (R2 range = 24.3%-37.3%, all Ps < or = 0.005). Most nonsignificant associations were found between superior RNFL sectors and superior VF zones. CONCLUSION: Retinal nerve fiber layer thickness measured with OCT is topographically correlated with glaucomatous VF defects measured with SWAP.

Adult↗

Confocal scanning laser ophthalmoscopy classifiers and stereophotograph evaluation for prediction of visual field abnormalities in glaucoma-suspect eyes.

PURPOSE: To determine whether Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Dossenheim, Germany) classification techniques and investigational support vector machine (SVM) analyses can detect optic disc abnormalities in glaucoma-suspect eyes before the development of visual field abnormalities. METHODS: Glaucoma-suspect eyes (n = 226) were classified as converts or nonconverts based on the development of repeatable (either two or three consecutive) standard automated perimetry (SAP)-detected abnormalities over the course of the study (mean follow-up, approximately 4.5 years). Hazard ratios for development of SAP abnormalities were calculated based on baseline classification results, follow-up time, and end point status (convert, nonconvert). Classification techniques applied were HRT classification (HRTC), Moorfields Regression Analysis, forward-selection optimized SVM (SVM fwd) and backward elimination-optimized SVM (SVM back) analysis of HRT data, and stereophotograph assessment. RESULTS: Univariate analyses indicated that all classification techniques were predictors of the development of two repeatable abnormal SAP results, with hazards ratios (95% confidence interval [CI]) ranging from 1.32 (1.00-1.75) for HRTC to 2.0 (1.48-2.76) for stereophotograph assessment (all P < or = 0.05). Only SVM (SVM fwd and SVM back) analysis of HRT data and stereophotograph assessment were univariate predictors of the development of three repeatable abnormal SAP results, with hazard ratios (95% CI) ranging from 1.73 (1.16-2.82) for SVM fwd to 1.82 (1.19-3.12) for SVM back (both P < 0.007). Multivariate analyses including each classification technique individually in a model with age, baseline SAP pattern standard deviation [PSD], and baseline IOP indicated that all classification techniques except HRTC (P = 0.06) were predictors of the development of two repeatable abnormal SAP results with hazards ratios ranging from 1.30 (0.99, 1.73) for HRTC to 1.90 (1.37, 2.69) for stereophotograph assessment. Only SVM (SVM fwd and SVM back) analysis of HRT data and stereophotograph assessment were significant predictors of the development of three repeatable abnormal SAP results in multivariate analyses; hazard ratios of 1.57 (1.03, 2.59) and 1.70 (1.18, 2.51), respectively. SAP PSD was a significant predictor of two repeatable abnormal SAP results in multivariate models with all classification techniques, with hazard ratios ranging from 3.31 (1.39, 7.89) to 4.70 (2.02, 10.93) per 1-dB increase. CONCLUSIONS: HRT classifications techniques and stereophotograph assessment can detect optic disc topography abnormalities in glaucoma-suspect eyes before the development of SAP abnormalities. These data support strongly the importance of optic disc examination for early glaucoma diagnosis.

Adult↗

Heidelberg retina tomograph measurements of the optic disc and parapapillary retina for detecting glaucoma analyzed by machine learning classifiers.

PURPOSE: To determine whether topographical measurements of the parapapillary region analyzed by machine learning classifiers can detect early to moderate glaucoma better than similarly processed measurements obtained within the disc margin and to improve methods for optimization of machine learning classifier feature selection. METHODS: One eye of each of 95 patients with early to moderate glaucomatous visual field damage and of each of 135 normal subjects older than 40 years participating in the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS) were included. Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Dossenheim, Germany) mean height contour was measured in 36 equal sectors, both along the disc margin and in the parapapillary region (at a mean contour line radius of 1.7 mm). Each sector was evaluated individually and in combination with other sectors. Gaussian support vector machine (SVM) learning classifiers were used to interpret HRT sector measurements along the disc margin and in the parapapillary region, to differentiate between eyes with normal and glaucomatous visual fields and to compare the results with global and regional HRT parameter measurements. The area under the receiver operating characteristic (ROC) curve was used to measure diagnostic performance of the HRT parameters and to evaluate the cross-validation strategies and forward selection and backward elimination optimization techniques that were used to generate the reduced feature sets. RESULTS: The area under the ROC curve for mean height contour of the 36 sectors along the disc margin was larger than that for the mean height contour in the parapapillary region (0.97 and 0.85, respectively). Of the 36 individual sectors along the disc margin, those in the inferior region between 240 degrees and 300 degrees, had the largest area under the ROC curve (0.85-0.91). With SVM Gaussian techniques, the regional parameters showed the best ability to discriminate between normal eyes and eyes with glaucomatous visual field damage, followed by the global parameters, mean height contour measures along the disc margin, and mean height contour measures in the parapapillary region. The area under the ROC curve was 0.98, 0.94, 0.93, and 0.85, respectively. Cross-validation and optimization techniques demonstrated that good discrimination (99% of peak area under the ROC curve) can be obtained with a reduced number of HRT parameters. CONCLUSIONS: Mean height contour measurements along the disc margin discriminated between normal and glaucomatous eyes better than measurements obtained in the parapapillary region.

Area Under Curve↗

Glaucoma detection using scanning laser polarimetry with variable corneal polarization compensation.

OBJECTIVE: To compare the ability of scanning laser polarimetry (SLP) to discriminate between healthy and glaucomatous eyes with manufacturer-assumed fixed and subject-specific variable corneal polarization magnitude (CPM) and corneal polarization axis (CPA) values. METHODS: An SLP was modified to enable the measurement of CPM and CPA values so that compensation for corneal birefringence could be corrected on a subject-specific variable basis. We examined 40 healthy eyes and 54 glaucomatous eyes with repeatable visual field damage (average +/- SD mean deviation, -6.5 +/- 4.9 dB) were examined by SLP using the manufacturer-assumed fixed corneal compensation (FCC-SLP) values and subject-specific variable corneal compensation (VCC-SLP) values. Areas under the receiver operating characteristic (ROC) curve for discriminating between healthy and glaucomatous eyes using FCC-SLP and VCC-SLP parameters were compared. RESULTS: The areas under the ROC curve increased with VCC-SLP compared with FCC-SLP, particularly for all thickness parameters. The parameters with which the area under the ROC curve improved significantly from FCC-SLP to VCC-SLP included average thickness (ROC curve area, 0.62 vs 0.75), superior integral (0.66 vs 0.79), ellipse average (0.65 vs 0.80), inferior average (0.66 vs 0.80), and superior average (0.68 vs 0.83). CONCLUSION: Variable corneal compensation to correct for subject-specific CPM and CPA can improve the ability of SLP to discriminate between healthy and glaucomatous eyes.

Aged↗

Association between scanning laser polarimetry measurements using variable corneal polarization compensation and visual field sensitivity in glaucomatous eyes.

OBJECTIVE: To compare the association between scanning laser polarimetry (SLP) retinal nerve fiber layer (RNFL) measurements and automated perimetry sensitivity using both SLP manufacturer-assumed fixed and subject-specific variable corneal polarization magnitude and corneal polarization axis values. METHODS: An SLP was modified to enable the measurement of corneal polarization magnitude and corneal polarization axis so that compensation for corneal birefringence could be corrected on a subject-specific variable basis. Seventy-three eyes from the University of California, San Diego, Diagnostic Innovations in Glaucoma Study with early glaucoma or suspected glaucoma (abnormal Swedish Interactive Threshold Algorithm [SITA] or full-threshold automated perimetry results and/or glaucomatous-appearing optic disc by consensus grading of stereoscopic optic disc photographs) (mean [SD] SITA mean deviation, -2.74 [3.71] dB; range, 1.72 to -14.72 dB) were included. Subjects were imaged with SLP using the manufacturer-assumed fixed corneal compensation values and subject-specific variable corneal compensation values and tested with SITA automated perimetry. Scanning laser polarimetry and SITA data were obtained within 3 months of each other. MAIN OUTCOME MEASURES: The relationship between regional SLP RNFL measurements (24 parameters) and corresponding regional SITA raw thresholds were evaluated using linear regression for both (fixed corneal compensation and variable corneal compensation) SLP configurations. RESULTS: No fixed corneal compensation SLP measurements were significantly associated with corresponding SITA visual field zone sensitivities after corrections for multiple comparisons. Seven variable corneal compensation RNFL parameters (superior, inferior, or mean RNFL thickness measurements) were significantly associated with their corresponding visual field zones with R2 values ranging from 0.13 (ellipse average) to 0.20 (superior average). CONCLUSION: Variable corneal compensation to correct for subject-specific corneal polarization magnitude and corneal polarization axis improves the relationship between SLP-measured RNFL thickness and visual function measured by SITA perimetry.

Adult↗