Auditory sensitivity in children using the auditory steady-state response.

OBJECTIVE: To determine the effectiveness of auditory steady-state response (ASSR) as a measure of hearing sensitivity in young children suspect for significant hearing loss. DESIGN: Within-subject comparisons of click auditory brainstem response (ABR) thresholds and ASSR thresholds. SUBJECTS: The study population comprised 42 children suspect for hearing loss and subsequently referred for hearing assessment using electrophysiologic techniques. MAIN OUTCOME MEASURES: Electrophysiologic threshold responses for click ABR and ASSR stimuli (0.5, 1, 2, and 4 kHz) for right and left ears. RESULTS: Based on ABR and ASSR thresholds, 50% of the subjects demonstrated significant hearing loss in the severe to profound range. In some subjects, ASSRs were present at higher stimulus levels when click ABRs were absent. Significant correlations (P<.05) were found between high-frequency ASSR and click ABR thresholds for this study sample. For some subjects, ASSR findings suggested differences between ears that were not observable from the no-response click ABR results. CONCLUSIONS: Auditory steady-state response testing may provide additional information for children who demonstrate hearing levels in the severe to profound range. This information may be helpful when selecting the ear for cochlear implantation for a young hearing-impaired child. Multiple objective methods, such as ABR and ASSR testing, may be needed to determine accurate hearing sensitivity for young children being considered for sensory devices, and in particular, cochlear implants.

Audiometry, Pure-Tone↗

Gamma knife radiosurgery for acoustic neuromas performed by a neurotologist: early experiences and outcomes.

OBJECTIVE: To assess early outcomes after Gamma knife radiosurgery of acoustic neuromas and other skull base tumors. BACKGROUND: Gamma knife radiosurgery is one of the available methods to treat acoustic neuromas, in addition to micro-surgical resection. Neuro-otologists have long been associated with microsurgical resection of these tumors; however, the application of Gamma knife radiosurgery to the treatment of these tumors by neuro-otologists has not been previously described. SETTING: Acoustic Neuroma and Skull Base Surgery Program / Tertiary Referral Center. STUDY DESIGN/PATIENTS/INTERVENTION: Prospective clinical study of all patients treated by the senior author and our gamma knife team beginning in June 2000. MAIN OUTCOME MEASURES: Preoperative MRI, audiometry, vestibular testing and facial nerve electromyography were completed. At six-month intervals postoperatively, audiometry, caloric testing and MRI were performed to determine thresholds and speech discrimination ability, vestibular function, and the size of the tumor. RESULTS: From June 2000 until March 2004, 38 patients were treated, and these included 33 acoustic neuromas, two meningiomas, one glomus jugulare tumor, and two facial neuromas. Greater than 36 month follow-up was available in 7 patients, > 24 months in 24, > 12 months in 31, and > 6 months in 34 patients. Statistically significant reduction in tumor size was seen over time, and tumor control was achieved in all but two patients. Various patterns of changes in auditory function, both in threshold and speech discrimination were observed in either positive or negative directions. CONCLUSIONS: Preliminary experience with Gamma knife radiosurgery indicates that this treatment method represents another option for neuro-otologists to use in managing patients with skull base tumors.

Follow-Up Studies↗

Electrically evoked auditory brain stem responses for lateral and medial placement of the Clarion HiFocus electrode.

OBJECTIVE: The purpose of this study was to compare the electrically evoked auditory brain stem response (EABR) for lateral and medial placement of the Clarion HiFocus cochlear implant electrode array via the electrode positioning system (EPS). DESIGN: Twenty-five adult and pediatric cochlear implant recipients participated in the study. Intraoperatively recorded EABRs were evoked by stimuli via three intracochlear electrodes representing apical, medial, and basal locations, and responses were elicited before and after positioner insertion. Evoked potential measures of wave V amplitude and threshold were examined for statistical significance using ANOVA for repeated measures and Chi-Square methods. RESULTS: For a given supra-threshold stimulus level, the increase in EABR wave V amplitude was significantly larger after EPS placement compared to before EPS placement for electrodes 1 (apical) and 13 (basal). Likewise, when the stimulus was decreased to obtain a minimal amplitude, the wave V threshold was significantly lower after EPS placement for electrodes 7 (medial) and 13. The number of measurements that showed decreased wave V threshold after EPS insertion was significantly dependent on intracochlear electrode location. CONCLUSIONS: Placement of the Clarion Electrode Positioning System following HiFocus electrode insertion resulted in a reduction in the electrical current required to activate the auditory system. The effect of the EPS was greatest for the basal location, demonstrated by lower wave V thresholds and a larger percentage increase in wave V amplitude. The EABR reflected electrophysiologic changes relative to lateral-to-medial changes in intracochlear electrode position due to the EPS.