PubMed Health⌕ Search

Biomedical subjects

Linda V E Caldas

Publications and source records attributed to Linda V E Caldas.

At least 19 recordsLinked to original sources

Generation of calibrated tungsten target x-ray spectra: modified TBC model.

In spite of the recent advances in the experimental detection of x-ray spectra, theoretical or semi-empirical approaches for determining realistic x-ray spectra in the range of diagnostic energies are important tools for planning experiments, estimating radiation doses in patients, and formulating radiation shielding models. The TBC model is one of the most useful approaches since it allows for straightforward computer implementation, and it is able to accurately reproduce the spectra generated by tungsten target x-ray tubes. However, as originally presented, the TBC model fails in situations where the determination of x-ray spectra produced by an arbitrary waveform or the calculation of realistic values of air kerma for a specific x-ray system is desired. In the present work, the authors revisited the assumptions used in the original paper published by . They proposed a complementary formulation for taking into account the waveform and the representation of the calculated spectra in a dosimetric quantity. The performance of the proposed model was evaluated by comparing values of air kerma and first and second half value layers from calculated and measured spectra by using different voltages and filtrations. For the output, the difference between experimental and calculated data was better then 5.2%. First and second half value layers presented differences of 23.8% and 25.5% in the worst case. The performance of the model in accurately calculating these data was better for lower voltage values. Comparisons were also performed with spectral data measured using a CZT detector. Another test was performed by the evaluation of the model when considering a waveform distinct of a constant potential. In all cases the model results can be considered as a good representation of the measured data. The results from the modifications to the TBC model introduced in the present work reinforce the value of the TBC model for application of quantitative evaluations in radiation physics.

Calibration↗

Preliminary dosimetric characterisation of thermoluminescent materials for beta radiation monitoring at nuclear medicine services.

Beta emitters are widely used in nuclear medicine for diagnostic and therapeutic purposes. The critical groups exposed to a radioactive patient include the staff, other patients and members of the public accompanying the patient. The aim of this work is to characterise thermoluminescent (TL) materials for the staff monitoring of nuclear medicine services that manipulate beta radiation solutions of (153)Sm. This study was performed using CaSO(4):Dy + Teflon pellets, produced at IPEN, with different dimensions. For the dosimetric characterisation, these TL dosemeters were exposed to gamma source ((60)Co) and to beta sealed sources ((90)Sr + (90)Y, (204)Tl and (147)Pm) and to a non-sealed source ((153)Sm). Results were obtained related to reproducibility, lower detection limits, calibration curves, angle and energy dependence of response. All tested materials show usefulness for monitoring of workers exposed to beta radiation.

Beta Particles↗

Influence of thermal treatments on the response of sand radiation detectors for high-dose dosimetry.

The dosimetric properties of sand from Brazilian beaches have shown to be useful for high-dose dosimetry. The thermoluminescent (TL) and electron paramagnetic resonance (EPR) techniques were utilised, and the sand samples were recently studied in relation to their main dosimetric properties. The EPR signal at g = 1.999 grows significantly in function of the absorbed dose, and the TL peaks appear at 110 and 170 degrees C. However, these sand samples present a post-irradiation thermal decay at room temperature, which is a problem for dosimetric procedures. In this study, sand samples have been studied in relation to different thermal treatments. Post-irradiation treatments were performed at 50 degrees C up to 230 degrees C.

Dose-Response Relationship, Radiation↗

Thermally stimulated luminescence and EPR studies on topaz.

In the present work, electron paramagnetic resonance (EPR) spectra and thermoluminescence (TL) emission of colourless natural topaz from Santo Antônio do Jacinto, Brazil, was studied as a function of thermal treatment and gamma irradiation dose, focussing on the use of this material as a radiation dosimeter. EPR measurements on "as-received" samples at room temperature provided signals in the region of about 500 at 5,000 G. The signal located around g approximately equal to 2, frequently attributed to (AlO(4))(0), increased with additional gamma dose and disappeared after thermal treatment at 500 degrees C for 1h. Irradiation after thermal treatment recovered this signal. The decay promoted by isochronal thermal treatment showed the (AlO(4))(0) defects to be directly related to the TL glows peaks. The variation of EPR spectrum with annealing temperature prior to irradiation showed that the variation of TL sensitivity is a consequence of the variation of the (AlO(4))(0) population.

Dose-Response Relationship, Radiation↗

A simple method for evaluation of half-value layer variation in CT equipment.

Tandem systems, each formed by a pencil ionization chamber with and without a specific covering, were developed and tested in standard radiation beams. These systems were designed to be used in computed tomography radiation beams, where the half-value layer (HVL) determination is not an easy task. The behaviour of the tandem systems in diagnostic radiology showed the possibility of their use to confirm HVL values previously determined by the conventional HVL measurement method in quality control programmes. These systems also have other advantages: low cost, easy application and quick measurement procedure.

Aluminum↗

A new extended-length parallel-plate ionization chamber.

A special parallel-plate ionization chamber was developed. The motivation for the construction of this new chamber was mainly to fulfil the need of a reference system for computed tomography standard beams in the Calibration Laboratory of IPEN. However, the chamber was tested also in standard radiation beams of mammography and conventional diagnostic radiology. The chamber was manufactured at the institute workshop, as simply and cheaply as possible. Its design differs from the common ionization chambers used in dosimetric procedures of computed tomography equipment, because it is a parallel-plate chamber instead of a cylindrical chamber. However, its dimensions and sensitive volume are very similar to those of a commercial pencil ionization chamber. The new ionization chamber was submitted to several characterization and quality control tests, showing its very good performance.

Biophysics↗

A special mini-extrapolation chamber for calibration of 90Sr+90Y sources.

90Sr+90Y applicators are commonly utilized in brachytherapy, including ophthalmic procedures. The recommended instruments for the calibration of these applicators are extrapolation chambers, which are ionization chambers that allow the variation of their sensitive volume. Using the extrapolation method, the absorbed dose rate at the applicator surface can be determined. The aim of the present work was to develop a mini-extrapolation chamber for the calibration of 90Sr+90Y beta ray applicators. The developed mini-chamber has a 3.0 cm outer diameter and is 11.3 cm in length. An aluminized polyester foil is used as the entrance window while the collecting electrode is made of graphited polymethylmethacrylate. This mini-chamber was tested in 90Sr+90Y radiation beams from a beta particle check source and with a plane ophthalmic applicator, showing adequate results.

Beta Particles↗

Evaluation of the depth-ratio and backscattering-factor methods in quality control measurements of electron beam energies.

Sensitivities of two different methods for evaluating electron beam energy have been investigated. One of them uses the ratio of ionization at two depths corresponding to two different points on the depth curve of ionization. The other one uses the magnitude of backscattering by lead as a measure of the electron beam energy. The depth-ratio method was found to be sensitive and practical for a routine quality control program. The sensitivity of the backscattering effect was found to be insufficient for electron energies higher than 12 MeV.

Algorithms↗

EPR dosimetry using commercial glasses for high gamma doses.

Commercial transparent and colored (bronze, brown, and green) glasses were studied as possible dosimeters for high gamma doses using electronic paramagnetic resonance (EPR). All EPR spectra showed the characteristic Fe3+ signals, g=4.27 and 2.01. The signal at g=2.01 presented a more useable behavior for the calibration curve. All samples showed their usefulness as high dose dosimeters.

Journal Article↗

Sand for high-dose dosimetry using the EPR technique.

The electronic paramagnetic resonance (EPR) technique was utilized to study sand samples from different Brazilian beaches for high-dose dosimetry. Sand also contains concentrations of heavy minerals. Sand samples were studied in relation to their main dosimetric properties: response reproducibility, reutilization, batch uniformity, detection range and dose response. The EPR signal grows significantly as a function of absorbed dose for g=1.999. All studied sand samples can be used as EPR dosimeters for different applications in medical, agricultural and industrial areas.

Journal Article↗

Coloured glasses for high dose dosimetry using the thermoluminescent technique.

Coloured glasses produced commercially by Cebracê, São Paulo, were analysed by the thermoluminescent (TL) method, to verify the possibility of their use as high-dose dosemeters or irradiation indicators in industrial areas, due to their easy handling and their low cost. The samples were exposed to different radiation doses, using the Gamma-Cell 220 system (60Co) of IPEN. The TL emission curves presented main peaks at 135, 150 and 145 degrees C in the bronze, brown and green glass samples, respectively. Calibration curves were obtained for the glasses between 50 Gy and 360 kGy. Reproducibility of TL response and the lower detection doses were determined for each kind of glass. All tested glasses showed their usefulness as irradiation indicators and as high-dose dosemeters.

Calibration↗

Performance of different thermoluminescence dosimeters in 90SR+90Y radiation fields.

The dosimetry of beta radiation is a difficult process especially because of the low penetration of beta particles in matter. The dosemeter utilised for this kind of procedure needs to approximate an ideal point-like detector: it should be as thin as possible, and its area should be small. The thermoluminescence dosemeters (TLDs) meet with these requirement properties. The aim of this work was to study the dosimetric characteristics of different TLDs to verify the possibility of their use for the calibration of 90Sr+90Y plane applicators. The response reproducibility, calibration curves, TL response as a function of the source-detector distance, the transmission factors and the linearity of the sample response were obtained for several types of dosimetric pellets.

Beta Particles↗

Properties of sintered amethyst pellets as thermoluminescent dosimeters.

The main dosimetric characteristics of amethyst, Brazilian natural semi-precious stone, were investigated in this work, in order to verify the possibility of its use for gamma-radiation detection using the thermoluminescent (TL) technique. The samples were tested in X- and gamma-radiation beams, and their TL glow curves, dependences of the response on the absorbed dose and radiation energy, and the response reproducibility were investigated. The preliminary results show the usefulness of this material in dosimetry for radiation processing.

Calibration↗

Response characteristics of a tandem ionization chamber in standard X-ray beams.

A tandem ionization chamber was developed for quality control programs of the kilovoltage X-ray equipment used in radiotherapy. This chamber was tested and calibrated in low-energy X-ray beams in accordance with international recommendations, and it showed a satisfactory level of performance, mainly with regard to its main use, namely formation of a tandem system for confirmation of half-value layers in X-radiation beams previously determined by the conventional method. In this developed system no absorbers or special setups are necessary.

Calibration↗

Evaluation of doses in radiotherapy using solid-state composites based on natural colourless topaz.

The thermoluminescent properties of composites containing powdered topaz embedded in Teflon or glass were studied and compared with the corresponding properties of the well known TLD-100 commercial dosimeters. Relative sensitivity, TL fading, reproducibility of the sample preparation process, and possibility of re-utilisation of the dosimeters were investigated. Measurements of absorbed doses in simulated radiotherapy treatments were also taken. The irradiations were performed using gamma rays from a 60Co source in the dose range from 1cGy to 2Gy. The dosimeters were installed in badges and attached inside acrylic plates of various thicknesses in the radiation fields. The dose profiles obtained with this procedure are very similar to the ones obtained with equivalent tissues. It is concluded that these composites of natural colourless topaz crystals can be efficiently used as TL dosimeters.

Aluminum Silicates↗

Performance of a pencil ionization chamber in various radiation beams.

Pencil ionization chambers were recommended for use exclusively in the computed tomography (CT) dosimetry, and, from the start, they were developed only with this application in view. In this work, we studied the behavior of a pencil ionization chamber in various radiation beams with the objective of extending its application. Stability tests were performed, and calibration coefficients were obtained for several standard radiation qualities of the therapeutical and diagnostic levels. The results show that the pencil ionization chamber can be used in several radiation beams other than those used in CT.

Calibration↗

Thin sintered Al2O3 pellets as thermoluminescent dosimeters for the therapeutic dose range.

Thermoluminescent properties of sintered alumina pellets were investigated with the aim of using them as radiation dosimeters. Peak temperatures, signal reproducibility, fading, curves of the response to X-radiation, as well as energy and angular dependences were studied. The results show that the pellets can be used in quality control programs in the therapeutic dose range.

Aluminum Oxide↗

Dosimetric properties of various colored commercial glasses.

Brazilian commercial glasses of various colors (bronze, brown and green) have been studied to evaluate their potential as radiation-sensitive materials in gamma high-dose dosimetry. Characteristics of their optical absorption responses (reproducibility, room temperature stability, and calibration curves) have been obtained using a spectrophotometer and a simple densitometer specially designed for glass samples. The glass spectra feature a decay at room temperature that has to be taken into consideration. The results show that the colored glasses can be used in dosimetry; the upper limit of the dose range depends on the glass type.

Journal Article↗