PubMed Health⌕ Search

Biomedical subjects

Linda X Hong

Publications and source records attributed to Linda X Hong.

2 recordsLinked to original sources

Postmastectomy CT-based electron beam radiotherapy: dosimetry, efficacy, and toxicity in 118 patients.

PURPOSE: To evaluate the technique, dosimetry, acute and late toxicity, local control (LC), and overall survival (OS) with the use of computed tomography (CT)-based postmastectomy electron beam therapy (PMEBT) in high-risk patients. METHODS AND MATERIALS: From 1990 to 2000, 118 patients with pathologic stage I-IIIB breast cancer underwent PMEBT of the chest wall (CW) (n = 3), CW and supraclavicular fossa (SCV) (n = 63), CW, SCV, and internal mammary lymph nodes (IMN) (n = 51), and SCV+IMN (n = 1). Radiation therapy was delivered with an en face electron beam with a custom cutout. Treatment plans were all CT-based. The plans of 16 patients were retrospectively reviewed to analyze dosimetry data. A retrospective chart review was conducted to assess acute and late complications, LC, and OS. RESULTS: At a median follow-up of 43 months, 5-year LC and OS were 91% and 61%, respectively. Sixty-one patients developed acute grade 3-4 skin toxicity, necessitating treatment breaks in 33 patients. Fifteen patients experienced a worsening of lymphedema, and 2 patients developed cardiac injury thought to be unrelated to radiotherapy. No patients developed symptomatic pneumonitis. Dosimetric analysis revealed heart and lung normal tissue complication probabilities of zero. Analysis of other clinically relevant dosimetric parameters revealed PMEBT to be comparable to previously reported techniques. CONCLUSION: Postmastectomy electron beam therapy is an effective way to deliver radiation to the postmastectomy chest wall and adjacent nodal sites. It offers acceptable acute and late toxicities and a high degree of local control given the high-risk population to which it is offered.

Adult↗

Intensity-modulated radiotherapy.

Intensity-modulated radiotherapy represents a recent advancement in conformal radiotherapy. It employs specialized computer-driven technology to generate dose distributions that conform to tumor targets with extremely high precision. Treatment planning is based on inverse planning algorithms and iterative computer-driven optimization to generate treatment fields with varying intensities across the beam section. Combinations of intensity-modulated fields produce custom-tailored conformal dose distributions around the tumor, with steep dose gradients at the transition to adjacent normal tissues. Thus far, data have demonstrated improved precision of tumor targeting in carcinomas of the prostate, head and neck, thyroid, breast, and lung, as well as in gynecologic, brain, and paraspinal tumors and soft tissue sarcomas. In prostate cancer, intensity-modulated radiotherapy has resulted in reduced rectal toxicity and has permitted tumor dose escalation to previously unattainable levels. This experience indicates that intensity-modulated radiotherapy represents a significant advancement in the ability to deliver the high radiation doses that appear to be required to improve the local cure of several types of tumors. The integration of new methods of biologically based imaging into treatment planning is being explored to identify tumor foci with phenotypic expressions of radiation resistance, which would likely require high-dose treatments. Intensity-modulated radiotherapy provides an approach for differential dose painting to selectively increase the dose to specific tumor-bearing regions. The implementation of biologic evaluation of tumor sensitivity, in addition to methods that improve target delineation and dose delivery, represents a new dimension in intensity-modulated radiotherapy research.

Abdominal Neoplasms↗