PubMed Health⌕ Search

Biomedical subjects

Lionel Bouchet

Publications and source records attributed to Lionel Bouchet.

2 recordsLinked to original sources

Dynamic targeting image-guided radiotherapy.

Volumetric imaging and planning for 3-dimensional (3D) conformal radiotherapy and intensity-modulated radiotherapy (IMRT) have highlighted the need to the oncology community to better understand the geometric uncertainties inherent in the radiotherapy delivery process, including setup error (interfraction) as well as organ motion during treatment (intrafraction). This has ushered in the development of emerging technologies and clinical processes, collectively referred to as image-guided radiotherapy (IGRT). The goal of IGRT is to provide the tools needed to manage both inter- and intrafraction motion to improve the accuracy of treatment delivery. Like IMRT, IGRT is a process involving all steps in the radiotherapy treatment process, including patient immobilization, computed tomography (CT) simulation, treatment planning, plan verification, patient setup verification and correction, delivery, and quality assurance. The technology and capability of the Dynamic Targeting IGRT system developed by Varian Medical Systems is presented. The core of this system is a Clinac or Trilogy accelerator equipped with a gantry-mounted imaging system known as the On-Board Imager (OBI). This includes a kilovoltage (kV) x-ray source, an amorphous silicon kV digital image detector, and 2 robotic arms that independently position the kV source and imager orthogonal to the treatment beam. A similar robotic arm positions the PortalVision megavoltage (MV) portal digital image detector, allowing both to be used in concert. The system is designed to support a variety of imaging modalities. The following applications and how they fit in the overall clinical process are described: kV and MV planar radiographic imaging for patient repositioning, kV volumetric cone beam CT imaging for patient repositioning, and kV planar fluoroscopic imaging for gating verification. Achieving image-guided motion management throughout the radiation oncology process requires not just a single product, but a suite of integrated products to manipulate all patient data, including images, efficiently and effectively.

Humans↗

Dosimetry of high dose skeletal targeted radiotherapy (STR) with 166Ho-DOTMP.

A study was undertaken to determine the maximum tolerated dose of (166)Ho-DOTMP that could be administered safely, without negatively impacting marrow re-engraftment, in patients with multiple myeloma treated with melphalan prior to transplant. Ho-166 DOTMP is a tetraphosphonate that localizes rapidly to bone surface. The Ho-166 physical half-life is 26.8 hr and the maximum beta energy is 1.8 MeV. Standard dosimetry models were adapted for radiation absorbed dose estimates using data obtained from whole body counting of the low abundance photons emitted by (166)Ho. Eighty-three patients received high dose (166)Ho-DOTMP followed by melphalan and transplant of peripheral blood stem cells. Twenty-five patients also received 8 Gy total body radiation (TBI). Dosages administered ranged from 460 to 4476 mCi (166)Ho-DOTMP. Marrow dose was derived using the assumption that all radioactivity not excreted by 20 hours was localized to the bone surfaces, and applying the Eckerman bone and marrow dose model to the calculated bone residence times. The dosimetry of the urinary bladder and kidneys was important because of the rapid excretion of the non-targeted radioactivity via the urinary pathway. The dynamic bladder model was used for bladder wall surface dose, and the ICRP 53 kinetic model was used to model kidney kinetics with an additional blood component included. Marrow doses ranged from 13 to 59 Gy and successful hematapoietic recovery occurred. Bladder doses ranged from 4.7 to 157 Gy. Hemorrhagic cystitis occurred in some patients who received more than 40 Gy to the bladder wall surface. Bladder irrigation was successful in protecting patients from bladder toxicity. Kidney doses ranged from 0.5-7.9 Gy. Kidney toxicity in the form of thrombotic microangiopathy with renal dysfunction was observed, with the severity being related to Ho-166-DOTMP radiation dose and probably the dose rate as well. In a future trial, kidney dosimetry will be assessed using early serial gamma camera imaging and modifications will be implemented to reduce renal toxicity.

Antineoplastic Agents, Alkylating↗