PubMed Health⌕ Search

Biomedical subjects

Lisa Angelos

Publications and source records attributed to Lisa Angelos.

2 recordsLinked to original sources

Cardiac magnetic resonance parallel imaging at 3.0 Tesla: technical feasibility and advantages.

PURPOSE: To quantify changes in signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), specific absorption rate (SAR), RF power deposition, and imaging time in cardiac magnetic resonance imaging with and without the application of parallel imaging at 1.5 T and 3.0 T. MATERIALS AND METHODS: Phantom and volunteer data were acquired at 1.5 T and 3.0 T with and without parallel imaging. RESULTS: Doubling field strength increased phantom SNR by a factor of 1.83. In volunteer data, SNR and CNR values increased by factors of 1.86 and 1.35, respectively. Parallel imaging (reduction factor = 2) decreased phantom SNR by a factor of 1.84 and 2.07 when compared to the full acquisition at 1.5 T and 3.0 T, respectively. In volunteers, SNR and CNR decreased by factors of 2.65 and 2.05 at 1.5 T and 1.99 and 1.75 at 3.0 T, respectively. Doubling the field strength produces a nine-fold increase in SAR (0.0751 to 0.674 W/kg). Parallel imaging reduced the total RF power deposition by a factor of two at both field strengths. CONCLUSIONS: Parallel imaging decreases total scan time at the expense of SNR and CNR. These losses are compensated at higher field strengths. Parallel imaging is effective at reducing total power deposition by reducing total scan time.

Adult↗

Parallel MR imaging: a user's guide.

Parallel imaging is a recently developed family of techniques that take advantage of the spatial information inherent in phased-array radiofrequency coils to reduce acquisition times in magnetic resonance imaging. In parallel imaging, the number of sampled k-space lines is reduced, often by a factor of two or greater, thereby significantly shortening the acquisition time. Parallel imaging techniques have only recently become commercially available, and the wide range of clinical applications is just beginning to be explored. The potential clinical applications primarily involve reduction in acquisition time, improved spatial resolution, or a combination of the two. Improvements in image quality can be achieved by reducing the echo train lengths of fast spin-echo and single-shot fast spin-echo sequences. Parallel imaging is particularly attractive for cardiac and vascular applications and will likely prove valuable as 3-T body and cardiovascular imaging becomes part of standard clinical practice. Limitations of parallel imaging include reduced signal-to-noise ratio and reconstruction artifacts. It is important to consider these limitations when deciding when to use these techniques.

Artifacts↗