PubMed Health⌕ Search

Biomedical subjects

Lisheng Xu

Publications and source records attributed to Lisheng Xu.

3 recordsLinked to original sources

Baseline wander correction in pulse waveforms using wavelet-based cascaded adaptive filter.

Pulse diagnosis is a convenient, inexpensive, painless, and non-invasive diagnosis method. Quantifying pulse diagnosis is to acquire and record pulse waveforms by a set of sensor firstly, and then analyze these pulse waveforms. However, respiration and artifact motion during pulse waveform acquisition can introduce baseline wander. It is necessary, therefore, to remove the pulse waveform's baseline wander in order to perform accurate pulse waveform analysis. This paper presents a wavelet-based cascaded adaptive filter (CAF) to remove the baseline wander of pulse waveform. To evaluate the level of baseline wander, we introduce a criterion: energy ratio (ER) of pulse waveform to its baseline wander. If the ER is more than a given threshold, the baseline wander can be removed only by cubic spline estimation; otherwise it must be filtered by, in sequence, discrete Meyer wavelet filter and the cubic spline estimation. Compared with traditional methods such as cubic spline estimation, morphology filter and Linear-phase finite impulse response (FIR) least-squares-error digital filter, the experimental results on 50 simulated and 500 real pulse signals demonstrate the power of CAF filter both in removing baseline wander and in preserving the diagnostic information of pulse waveforms. This CAF filter also can be used to remove the baseline wander of other physiological signals, such as ECG and so on.

Algorithms↗

Wavelet-based cascaded adaptive filter for removing baseline drift in pulse waveforms.

This paper presents an energy ratio-based method and a wavelet-based cascaded adaptive filter (CAF) for detecting and removing baseline drift from pulse waveforms. Experiments on 50 simulated and five hundred real pulse signals demonstrate that this CAF outperforms traditional filters both in removing baseline drift and in preserving the diagnostic information of pulse waveforms.

Algorithms↗

Scattering matrix of infrared radiation by ice finite circular cylinders.

Scattering matrix characteristics of polydisperse, randomly oriented, small ice crystals modeled by finite circular cylinders with various ratios of the length to diameter (L/D) ratio are calculated by use of the exact T-matrix approach, with emphasis on the thermal infrared spectral region that extends from the atmospheric short-wave IR window to the far-IR wavelengths to as large as 30 microm. The observed ice crystal size distribution and the well-known power-law distribution are considered. The results of the extensive calculations show that the characteristics of scattering matrix elements of small ice circular cylinders depend strongly on wavelengths and refractive indices, particle size distributions, and the L/D ratios. The applicability of the power-law distribution and particle shapes for light scattering calculations for small ice crystals is discussed. The effects of the effective variance of size distribution on light scattering characteristics are addressed. It seems from the behavior of scattering matrix elements of small ice crystals that the combination of 25 and 3.979 microm has some advantages and potential applications for remote sensing of cirrus and other ice clouds.

Journal Article↗