Anodal capture in cardiac resynchronization therapy implications for device programming.

INTRODUCTION: Right ventricular (RV) anodal capture (AC) has been reported in cardiac resynchronization therapy (CRT), when left ventricular (LV) pacing uses pseudobipolar (LV tip to RV proximal electrode) configuration. The aim of the study was to analyze the prevalence of AC and its implications for device programming. METHODS AND RESULTS: When AC occurred, the resulting QRS morphology was evaluated with the following pacing modes: (1) LV tip pacing plus RV AC, (2) Biventricular (BiV) pacing (i.e., both LV and RV tip pacing), and (3) BiV pacing plus RV AC. Several interventricular pacing (VV) intervals from 50 ms of LV preactivation to 30 ms of RV preactivation were tested in modes 2 and 3. From 38 consecutive patients, AC was achieved in 14 (in 74% of the pacemakers and in none of the defibrillators). LV tip pacing plus RV AC obtained narrower QRS than BiV pacing at all VV intervals in seven of the patients with AC (50%). When BiV pacing is combined with RV AC, it produced a ventricular depolarization through two wave fronts (one from the LV tip and the second from either the ring or the tip of the RV lead depending on the VV interval programmed). CONCLUSIONS: AC obtained the narrowest QRS of all tested pacing modes in a significant proportion of patients undergoing CRT. Though the stimulus was delivered from three sites (BiV pacing plus RV AC mode), only two wave fronts of ventricular activation were seen by ECG.

Aged↗

Incidence of pulmonary vein stenosis in patients submitted to atrial fibrillation ablation: a comparison of the Selective Segmental Ostial Ablation vs the Circumferential Pulmonary Veins Ablation.

INTRODUCTION: Pulmonary vein (PV) stenosis is an important complication of the AF ablation and could be underestimated if their assessment is not systematically done. Selective Segmental Ostial Ablation (SSOA) and Circunferential Pulmonary Veins Ablation (CPVA) have demonstrated efficacy in atrial fibrillation (AF) treatment. In this study the real incidence of PV stenosis in patients (pts) submitted to both SSOA and CPVA was compared. METHODS: Those pts with focal activity and normal left atrial size were submitted to SSOA, remaining pts were submitted to CPVA to treat refractory, symptomatic AF. Contrast enhanced magnetic resonance angiography (MRA) was routinely performed in all patients 4 months after the procedure. RESULTS: A series of 73 consecutive patients (mean age of 51 +/- 11 years; 75% male) were included. SSOA was performed in 32 patients, and the remaining 41 patients underwent to CPVA, obtaining similar efficacy rates (72% vs 76% arrythmia free probability at 12 months; log rank test p = NS). Six patients had a significant PV stenosis, all in SSOA group none in CPVA group (18.8% vs 0%; p = 0.005). All patients were asymptomatic and the stenosis was detected in routine MRA. No predictors of stenosis has been identified analysing patient procedure characteristics. CONCLUSION: PV stenosis is a potential complication of SSOA not seen in CPVA. The study confirms than MRA is useful for identifying patients with asymptomatic PV stenosis.

Atrial Fibrillation↗

Electrocardiographic recognition of the epicardial origin of ventricular tachycardias.

BACKGROUND: Some ventricular tachycardias (VTs) originating from the epicardium are not suitable for endocardial radiofrequency ablation and require an epicardial approach. The aim of this study was to define the ECG characteristics that may identify an epicardial origin of VTs. METHODS AND RESULTS: We analyzed the 12-lead ECG recordings during epicardial and endocardial left ventricular pacing in 9 patients to verify the hypothesis that the epicardial origin of the ventricular activation widens the initial part of the QRS complex. Then, we analyzed the ECG pattern in 14 VTs successfully ablated from the epicardium after a failed endocardial approach (group A), in 27 VTs successfully ablated from the endocardium (group B), and in 28 additional VTs that could not be ablated from the endocardium (group C). Four distinct intervals of ventricular activation were defined and measured: (1) the pseudodelta wave, (2) the intrinsicoid deflection time in V2, (3) the shortest RS complex, and (4) the QRS complex. VTs from groups A and C showed a significantly longer pseudodelta wave, intrinsicoid deflection time, and RS complex duration compared with VTs of group B. There was no difference between groups A and C. A pseudodelta wave of > or =34 ms has a sensitivity of 83% and a specificity of 95%, an intrinsicoid deflection time of > or =85 ms has a sensitivity of 87% and a specificity of 90%, and an RS complex duration of > or =121 ms has a sensitivity of 76% and a specificity of 85% in identifying an epicardial origin of the VTs. CONCLUSIONS: ECG suggests VTs originating from the epicardium and those with an unsuccessful radiofrequency ablation from the endocardium.

Cardiac Pacing, Artificial↗

Orthodromic pacemaker-mediated tachycardia in a biventricular system without an atrial electrode.

Pacemaker-mediated tachycardia is a well-known complication of dual-chamber devices. In this report, we describe for the first time a case of orthodromic pacemaker-mediated tachycardia in a patient in whom a biventricular system without an atrial electrode had been implanted. Retrograde atrial activation was directly produced by the dislodged coronary vein electrode in the AV groove, resulting in simultaneous capture of the left atrium and left ventricle. During tachycardia, AV nodal conduction was via the anterograde pathway of the circuit and limited the ventricular response. Subsequently, right ventricular activation was sensed by the right ventricular electrode that triggered biventricular pacing and left atrial capture, perpetuating the tachycardia. Because the left atrial threshold was higher than the left ventricular threshold, the problem could be resolved easily by lowering the output of the coronary vein electrode.

Aged↗

Nonsurgical transthoracic epicardial radiofrequency ablation: an alternative in incessant ventricular tachycardia.

OBJECTIVES: The purpose of this study was to analyze the feasibility, efficacy, and safety of epicardial radiofrequency (RF) ablation in patients with incessant ventricular tachycardia (VT). BACKGROUND: Management of patients with incessant VT is a difficult clinical problem. Drugs and RF catheter ablation are not always effective. A nonsurgical transthoracic epicardial RF ablation can be an alternative in patients refractory to conventional therapy. METHODS: Epicardial RF ablation was performed in 10 patients who presented with incessant VT despite the use of two or more intravenous antiarrhythmic drugs. RESULTS: In eight patients, endocardial ablation (EdA) failed to control the tachycardia. In the remaining two patients, epicardial ablation (EpA) was first attempted because of left ventricular thrombus and severe artery disease, respectively. Eight patients had a diagnosis of coronary artery disease with healed myocardial infarction. One patient had dilated cardiomyopathy, and one patient had idiopathic, incessant VT. In patients with structural heart disease, the mean ejection fraction was 0.28 +/- 0.10%. Four patients previously received an implantable defibrillator. The EpA effectively terminated the incessant tachycardia in eight patients, which represents a success rate of 80%. In them, after a follow-up of 18 +/- 18 months, a single episode of a different VT was documented in one patient. No significant complications occurred related to the procedure. CONCLUSIONS: In patients with incessant VT despite the use of drugs or standard EdA, the epicardial approach was very effective and should be considered as an alternative in this life-threatening situation.

Aged↗

Natural history of Brugada syndrome: the prognostic value of programmed electrical stimulation of the heart.

INTRODUCTION: The prognostic value of electrophysiologic studies in individuals with the syndrome of right bundle branch block and ST segment elevation in precordial leads V1 to V3 (Brugada syndrome) remains controversial. Our previous data from 252 individuals with the syndrome suggested that programmed ventricular stimulation had a good overall accuracy to predict events. However, studies from independent investigators questioned our results. We report here the largest population with Brugada syndrome ever studied by programmed electrical stimulation of the heart. METHODS AND RESULTS: Four hundred forty-three individuals with an ECG diagnostic of Brugada syndrome were studied by programmed electrical stimulation of the heart. The diagnosis was made because of the classic ECG showing a coved-type ST segment elevation in precordial leads V1 to V3. Of the 443 individuals, 180 had developed spontaneous symptoms (syncope or aborted sudden cardiac death) and 263 were asymptomatic at the time the diagnosis was made. The ventricular stimulation protocol included a minimum of two basic pacing cycle lengths with two ventricular premature beats from the right ventricular apex. A sustained ventricular arrhythmia was induced in 217 cases (49%). Symptomatic patients were more frequently inducible [126/180 (70%)] than asymptomatic individuals [91/263 (34%); P = 0.0001]. Males were more frequently inducible than females (54% vs 32%, P < 0.0001). Inducible individuals had a longer HV interval than noninducible patients (50 +/- 12 msec vs 46 +/- 10 msec, P < 0.002). HV interval and number of premature beats needed to induce VF were not related to outcome. Inducibility was statistically a powerful predictor of arrhythmic events during follow-up. Sixty of 217 inducible patients (28%) had spontaneous ventricular fibrillation compared with 5 of 221 noninducible patients (2%; P = 0.0001). CONCLUSION: Inducibility of sustained ventricular arrhythmias during programmed ventricular stimulation of the heart is a good predictor of outcome in Brugada syndrome.

Adolescent↗

Surgical treatment of pacemaker and defibrillator lead endocarditis: the impact of electrode lead extraction on outcome.

BACKGROUND: Cardiac device (CD) endocarditis is an infrequent but potentially lethal infectious complication of permanent pacemakers or implantable cardioverter-defibrillators (ICDs), and mortality rates of 30 to 35% have been reported. Medical treatment has been suggested for the treatment of CD endocarditis, but there is increasing evidence that surgical treatment is to be preferred as the best approach to achieve eradication of the infection and reduce mortality. OBJECTIVE: To evaluate the following: (1) the clinical and echocardiographic characteristics of patients with pacemaker or ICD endocarditis, (2) the outcome of this population depending on the mode of treatment (medical vs surgical treatment), and (3) the clinical, microbiological, echocardiographic, and therapeutic variables associated with patient outcome. DESIGN: Prospective cohort study. SETTING: Tertiary referral center in Barcelona, Spain. PATIENTS: All consecutive patients with infectious endocarditis (IE) admitted to the study institution between 1990 and 2001 were prospectively evaluated by a multidisciplinary treatment team, and a definite diagnosis of CD endocarditis was established when cases met pathologic or clinical criteria according to the Duke criteria. RESULTS: A total of 31 patients, 25 men and 6 women aged 61 +/- 15 years (mean +/- SD), with pacemaker or ICD endocarditis were identified among 669 consecutive patients (4.6%) with IE. During the study period, a total of 3,768 pacemakers and 460 ICDs were implanted in the study institution. In 22 cases of pacemaker endocarditis, the pacemaker was implanted in our institution, and 9 cases were referred from other institutions (incidences of endocarditis on pacemaker and ICD implanted in our institution of 0.58% and 0.65%, respectively). Medical treatment without removal of the pacing system was initially performed on seven patients; all of them (100%) had relapses of endocarditis, and one patient died. The remaining 24 patients underwent surgical removal of the pacing system; 1 patient had one relapse, 3 patients died after surgical treatment, and the others were successfully cured with no relapses after a mean follow-up of 38 +/- 9 months. Clinical, echocardiographic, microbiological, and therapeutic variables were evaluated in association with prognosis. The only prognostic factor for failure of treatment or mortality was the absence of surgical treatment (p < 0.0001). CONCLUSIONS: Electrode lead endocarditis occurred in < 1% of pacemaker and ICD implants. Conservative treatment without explantation of all hardware failed in all patients, and surgical treatment during antibiotic therapy was effective in eradication of infection but was associated with a 12.5% mortality. The only patient characteristic associated with treatment failure or death was the absence of surgical removal of all infected hardware. Complete extraction of the pacemaker or ICD should be considered as standard therapy for most patients with CD endocarditis.

Aged↗