PubMed Health⌕ Search

Biomedical subjects

Long-Hao Li

Publications and source records attributed to Long-Hao Li.

6 recordsLinked to original sources

Hydroxyapatite-TiO2 hybrid coating on Ti implants.

A hydroxyapatite (HA)-titania (TiO(2)) hybrid coating is developed to improve the biocompatibility of titanium (Ti) implants. The HA predeposited layer on Ti via electron beam (e-beam) evaporation is subsequently treated by micro-arc oxidation (MAO) to produce an HA-TiO(2) hybrid layer on Ti. The e-beam-deposited HA layer has a thickness of approximately 1 microm and was highly dense prior to MAO. By means of MAO treatment, a rough and porous TiO(2) layer is formed beneath the HA layer with a simultaneous local dissolution of the HA layer. Due to the HA precoating, high concentrations of Ca and P are preserved on the coating surface. The osteoblast-like cells on the hybrid coating layer grow and spread favorably. The cell proliferation rate on the hybrid coatings is not much different from that on pure Ti or simple MAO-treated Ti. However, the alkaline phosphatase (ALP) activity of the cells is significantly higher (p < 0.05) on the HA-TiO(2) hybrid coatings than on either the pure Ti or the simple MAO-treated specimen, suggesting that the cellular activity on the hybrid coatings is improved.

Cell Line↗

Fibrillar assembly and stability of collagen coating on titanium for improved osteoblast responses.

Collagen, as a major constituent of human connective tissues, has been regarded as one of the most important biomaterials. As a coating moiety on Ti hard-tissue implants, the collagen has recently attracted a great deal of attention. This article reports the effects of fibrillar assembly and crosslinking of collagen on its chemical stability and the subsequent osteoblastic responses. The fibrillar self-assembly of collagen was carried out by incubating acid-dissolved collagen in an ionic-buffered medium at 37 degrees C. The degree of assembly was varied with the incubation time and monitored by the turbidity change. The differently assembled collagen was coated on the Ti and crosslinked with a carbodiimide derivative. The partially assembled collagen contained fibrils with varying diameters as well as nonfibrillar aggregates. On the other hand, the fully assembled collagen showed the complete formation of fibrils with uniform diameters of approximately 100-200 nm with periodic stain patterns within the fibrils, which are typical of native collagen fibers. Through this fibrillar assembly, the collagen coating had significantly improved chemical stability in both the saline and collagenase media. The subsequent crosslinking step also improved the stability of the collagen coating, particularly in the unassembled collagen. The fibrillar assembly and the crosslinking of collagen significantly influenced the osteoblastic cell responses. Without the assembly, the collagen layer on Ti adversely affected the cell attachment and proliferation. However, those cellular responses were improved significantly when the collagen was assembled to fibrils and the assembly degree was increased. After crosslinking the collagen coating, these cellular responses were significantly enhanced in the case of the unassembled collagen but were not altered much in the assembled collagen. Based on these observations, it is suggested that the fibrillar assembly and the crosslinking of collagen require careful considerations in the collagen administration as a coating moiety.

Cell Line↗

Biocompatibility of titanium implants modified by microarc oxidation and hydroxyapatite coating.

A thin hydroxyapatite (HA) layer was coated on a microarc oxidized titanium (MAO-Ti) substrate by means of the sol-gel method. The microarc oxidation (anodizing) enhanced the biocompatibility of the Ti, and the bioactivity was improved further by the sol-gel HA coating on the anodized Ti. The HA sol was aged fully to obtain a stable and phase-pure HA, and the sol concentration was varied to alter the coating thickness. Through the sol-gel HA coating, the Ca and P concentrations in the coating layer increased significantly. However, the porous morphology and roughness of the MAO-Ti was altered very little by the sol-gel treatment. The proliferation and alkaline phosphatase (ALP) activity of the osteoblast-like cells on the MAO/HA sol-gel-treated Ti were significantly higher than those on the MAO-Ti without the HA sol-gel treatment.

Absorbable Implants↗

Mechanical performance and osteoblast-like cell responses of fluorine-substituted hydroxyapatite and zirconia dense composite.

A fluorine-substituted hydroxyapatite (FHA) and zirconia (ZrO(2)) dense composite (50:50 by volume) was fabricated, and its feasibility for hard tissue applications was investigated in terms of its mechanical properties and osteoblast-like cell (MG63) responses in vitro. The incorporation of fluorine into the hydroxyapatite (HA) structure was highly effective in producing a completely dense apatite-ZrO(2) composite through a pressureless sintering route, by preventing the thermal degradation of the apatite and ZrO(2). The resultant FHA-ZrO(2) dense composite had excellent mechanical properties, such as flexural strength (310 MPa), fracture toughness (3.4 MPam(1/2)), hardness (10 GPa), and elastic modulus (160 GPa). The flexural strength and fracture toughness of the composite showed a noticeable improvement by a factor of approximately 4 with respect to the pure apatites (HA and FHA). The MG63 cellular responses to the composite were assessed in terms of the cell proliferation (cell number and [(3)H]-thymidine incorporation) and differentiation (alkaline phosphatase activity, osteocalcin, and collagen production). The cells on the FHA-ZrO(2) composite spread and grew well, and proliferated actively during the culture period. The expression of alkaline phosphatase, osteocalcin, and collagen by the cells on the composite showed a similar trend to that on the pure apatites, although slight down-regulations were observed, implying that the FHA-ZrO(2) 50:50 composite retains the osteoblastic functionality and traits of the pure HA ceramics to a high degree. This finding, in conjunction with the considerable improvements in mechanical properties, supports the extended use of this composite for hard tissue applications.

Biocompatible Materials↗

Hydroxyapatite coating on titanium substrate with titania buffer layer processed by sol-gel method.

Hydroxyapatite (HA) was coated onto a titanium (Ti) substrate with the insertion of a titania (TiO2) buffer layer by the sol-gel method. The HA layer was employed to enhance the bioactivity and osteoconductivity of the Ti substrate, and the TiO2 buffer layer was inserted to improve the bonding strength between the HA layer and Ti substrate, as well as to prevent the corrosion of the Ti substrate. The HA layer coated over the TiO2 showed a typical apatite phase at 400 degrees C and the phase intensity increased above 450 degrees C. The sol-gel derived HA and TiO2 films, with thicknesses of approximately 800 and 200 nm, respectively, adhered tightly to each other and to the Ti substrate. The bonding strength of the HA/TiO2 double layer coating on Ti was markedly improved when compared to that of the HA single coating on Ti. The highest strength of the double layer coating was 55 MPa after heat treatment at 500 degrees C. The improvement in bonding strength with the insertion of TiO2 was attributed to the resulting enhanced chemical affinity of TiO2 toward the HA layer, as well as toward the Ti substrate. Human osteoblast-like cells, cultured on the HA/TiO2 coating surface, proliferated in a similar manner to those on the TiO2 single coating and on the pure Ti surfaces. However, the alkaline phosphatase activity of the cells on the HA/TiO2 double layer was expressed to a higher degree than that on the TiO2 single coating and pure Ti surfaces. The corrosion resistance of Ti was improved by the presence of the TiO2 coating, as confirmed by a potentiodynamic polarization test.

Buffers↗

Improved biological performance of Ti implants due to surface modification by micro-arc oxidation.

The surface of a titanium (Ti) implant was modified by micro-arc oxidation (MAO) treatment. A porous layer was formed on the Ti surface after the oxidation treatment. The phase and morphology of the oxide layer were dependent on the voltage applied during the oxidation treatment. With increasing voltage, the roughness and thickness of the film increased and the TiO(2) phase changed from anatase to rutile. During the MAO treatment, Ca and P ions were incorporated into the oxide layer. The in vitro cell responses of the specimen were also dependant on the oxidation conditions. With increasing voltage, the ALP activity increased, while the cell proliferation rate decreased. Preliminary in vivo tests of the MAO-treated specimens on rabbits showed a considerable improvement in their osseointegration capability as compared to the pure titanium implant.

Animals↗