PubMed Health⌕ Search

Biomedical subjects

Lorenz Jäger

Publications and source records attributed to Lorenz Jäger.

7 recordsLinked to original sources

Sound level dependence of the primary auditory cortex: Simultaneous measurement with 61-channel EEG and fMRI.

Sound level dependence has been investigated for years with event-related potentials (ERP). A serotonergic modulation of the sound level dependence only of the primary auditory cortex but not of the auditory association cortex has been suggested by a number of clinical and preclinical studies. Therefore, a precise covering of the activity of the primary auditory cortex seems necessary if sound level dependence is used as an indicator of the central serotonergic system. Recent fMRI studies described a pronounced sound level dependence only in the Heschl gyrus/primary auditory cortex but not in auditory association areas. In the present simultaneous 61-channel EEG and fMRI study investigating fourteen healthy subjects, we found a high correlation between the loudness-dependent change of the extent of fMRI activation (number of activated voxels) and the corresponding changes of the mean current source density within the same region of interest covering the primary auditory cortex (r = 0.84, P < 0.001). Our findings suggest a close relationship between the fMRI signal and event-related potential activity. In addition, the correspondence of the ERP-based data and the fMRI results further supports the validity of the ERP localization approach.

Acoustic Stimulation↗

Formation of a novel surface structure encoded by Salmonella Pathogenicity Island 2.

The type III secretion system (T3SS) encoded by Salmonella Pathogenicity Island 2 (SPI2) is essential for virulence and intracellular proliferation of Salmonella enterica. We have previously identified SPI2-encoded proteins that are secreted and function as a translocon for the injection of effector proteins. Here, we describe the formation of a novel SPI2-dependent appendage structure in vitro as well as on the surface of bacteria that reside inside a vacuole of infected host cells. In contrast to the T3SS of other pathogens, the translocon encoded by SPI2 is only present singly or in few copies at one pole of the bacterial cell. Under in vitro conditions, appendages are composed of a filamentous needle-like structure with a diameter of 10 nm that was sheathed with secreted protein. The formation of the appendage in vitro is dependent on acidic media conditions. We analyzed SPI2-encoded appendages in infected cells and observed that acidic vacuolar pH was not required for induction of SPI2 gene expression, but was essential for the assembly of these structures and their function as translocon for delivery of effector proteins.

Animals↗

CT of the normal temporal bone: comparison of multi- and single-detector row CT.

PURPOSE: To evaluate multi- and single-detector row computed tomographic (CT) depiction of anatomic landmarks of temporal bone. MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained. In 50 temporal bones, transverse and coronal single-detector row CT images were compared with transverse and reformatted coronal multi-detector row CT images obtained of additional 50 temporal bones. Two radiologists evaluated images. Visibility of 50 landmarks was scored with a five-point quality rating scale. Fisher exact test, kappa statistics, and Mann-Whitney U test were used to evaluate imaging technique and landmark visibility. RESULTS: In delineating landmarks, total interobserver agreement was higher (P < .001) for transverse multi- than for single-detector row CT images. In 60% of landmarks, interobserver agreement was higher (P < .001) for transverse multi- than for single-detector row CT images. In 20% of landmarks, there was no difference, and in another 20% of landmarks, interobserver agreement was higher (P < .01) for single-detector row CT. Total interobserver agreement was higher (P < .01) for coronal multi-detector row reformations than for coronal single-detector row images. In 58% of landmarks, interobserver agreement was higher (P < .001) for coronal multi-detector row reformations than for coronal single-detector row images, while there was no difference in 8%. In 34% of landmarks, interobserver agreement was higher (P < .001) for coronal single-detector row images. Frequency of detected landmarks was higher for transverse (82%) and coronal (88%) multi-detector row images than for corresponding single-detector row images. In 72% of landmarks, transverse multi-detector row images were (P < .05) superior to corresponding transverse single-detector row images in landmark delineation. In 56% of landmarks, reformatted coronal multi-detector row images were (P < .05) superior to coronal single-detector row images in landmark delineation. CONCLUSION: Multi-detector row CT images, including reformations, better delineate temporal bone anatomy than do single-detector row CT images.

Female↗

Optimization of MDCT of the wrist to achieve diagnostic image quality with minimum radiation exposure.

OBJECTIVE: This study tests various acquisition and reconstruction protocols for MDCT of the wrist to determine the optimal protocol for obtaining diagnostic image quality with minimal radiation exposure. MATERIALS AND METHODS: Thirty anatomic specimens were examined with an MDCT collimation of 4.0 x 1.0 mm and 2.0 x 0.5 mm (80, 120, and 140 kV; 80, 100, 130, 160, and 200 mA; rotation time, 0.5 0.75, 1.0 sec; pitch, 1.0, 1.3, 1.5, and 2.0). Coronal images were reconstructed using a slice thickness of 0.5, 1.0, and 2.0 mm with 60% overlap. Three observers evaluated all images independently for gross and fine anatomic detail. Diagnostic confidence was tested using Shrout-Fleiss intraclass correlation coefficients. Interobserver agreement was assessed by Kappa statistics and the Kruskal-Wallis test. RESULTS: Fine anatomic detail was best presented in 0.5-mm or 1.00-mm reconstructions based on a 2.0 x 0.5 mm acquisition. A rotation time of > or = 0.75 sec resulted in fewer artifacts; a significant dose reduction was achieved with 80 kV and 100 mA at the expense of somewhat increased noise, but without significant loss of anatomic detail in bone presentation. Artifacts were tolerable with a pitch of 1.5 or less. CONCLUSION: MDCT at the described optimal settings allows significant dosage reduction without sacrificing image quality. An acquisition and reconstruction thickness of 0.5 mm results in the best depiction of anatomic detail. A reconstruction thickness of 1.0 mm with a reconstruction interval of 0.5 mm represents a good trade-off between noise and resolution when using low-dose protocols.

Aged↗

Integration of fMRI and simultaneous EEG: towards a comprehensive understanding of localization and time-course of brain activity in target detection.

fMRI and EEG are complimentary methods for the analysis of brain activity since each method has its strength where the other one has limits: The spatial resolution is thus in the range of millimeters with fMRI and the time resolution is in the range of milliseconds with EEG. For a comprehensive understanding of brain activity in target detection, nine healthy subjects (age 24.2 +/- 2.9) were investigated with simultaneous EEG (27 electrodes) and fMRI using an auditory oddball paradigm. As a first step, event-related potentials, measured inside the scanner, have been compared with the potentials recorded in a directly preceding session in front of the scanner. Attenuated amplitudes were found inside the scanner for the earlier N1/P2 component but not for the late P300 component. Second, an independent analysis of the localizations of the fMRI activations and the current source density as revealed by low resolution electromagnetic tomography (LORETA) has been done. Concordant activations were found in most regions, including the temporoparietal junction (TPJ), the supplementary motor area (SMA)/anterior cingulate cortex (ACC), the insula, and the middle frontal gyrus, with a mean Euclidean distance of 16.0 +/- 6.6 mm between the BOLD centers of gravity and the LORETA-maxima. Finally, a time-course analysis based on the current source density maxima was done. It revealed different time-course patterns in the left and right hemisphere with earlier activations in frontal and parietal regions in the right hemisphere. The results suggest that the combination of EEG and fMRI permits an improved understanding of the spatiotemporal dynamics of brain activity.

Acoustic Stimulation↗

Labyrinth dysfunction 8 months after cochlear implantation: a case report.

OBJECTIVE: Investigate whether the cochleostomy is a possible port of entry for pneumolabyrinth and a resulting vertigo in patients provided with a cochlear implant. STUDY DESIGN: Retrospective case review. SETTING: Ludwig-Maximilians University of Munich, Hospital Grosshadern. PATIENT: 62-year-old patient who underwent implantation of a HiFocus II cochlear implant with positioner from Advanced Bionics (CLARION). Eight months postoperatively, the patient reported rotatory vertigo and right-side tinnitus after he had blown his nose harder than usual during an episode of rhinitis. INTERVENTIONS: Preoperative and postoperative testing of both the petrosal bone with a CT scan and of balance function. MAIN OUTCOME MEASURE: Air inclusion in the labyrinth. RESULTS: In contrast to the preoperative high resolution computed tomography (CT) scan, air inclusion was seen in the labyrinth during the episode of vertigo. At the same time, balance function tests with Frenzel glasses revealed both spontaneous and provoked horizontal nystagmus to the right side. At follow-up 8 weeks later, the level of vertigo had significantly decreased. Twelve months later, the control CT showed the cochlear implant positioned correctly and no visible air in the labyrinth. CONCLUSION: It is known that placement of the HiFocus II with Positioner from CLARION requires a relatively large cochleostomy of 1.5 mm. Moreover, in the connective tissue seal between the electrode and the positioner, the latter reaches into the tympanic cavity, and this is possibly the weak point. Further investigation will be needed to determine whether the large cochleostomy with the HiFocus II with positioner increases the predisposition to labyrinth dysfunction.

Cochlear Implantation↗

Focal epileptiform activity in the brain: detection with spike-related functional MR imaging--preliminary results.

The purpose of this study was to develop a spike-related functional magnetic resonance (MR) imaging method to detect epileptic brain activity. Correlations between simultaneous spike-related functional MR imaging and electroencephalographic (EEG) recordings were performed in 10 patients with focal epilepsy. Postprocessing techniques were implemented to eliminate contamination of the EEG recording from ballistocardiography and the echo-planar MR imaging sequence. A diagnostic EEG recording was achieved during functional MR imaging. Spike location correlated with the site of blood oxygen level-dependent signal increase. Spike-related functional MR imaging is a promising technique for detecting focal epileptic brain activity.

Adult↗