PubMed Health⌕ Search

Biomedical subjects

Lorne Beckman

Publications and source records attributed to Lorne Beckman.

5 recordsLinked to original sources

Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model.

BACKGROUND: Newer internal fixation devices with a locking mechanism between the plate and the screw have recently been released. The efficacy of these plates in the proximal humerus has yet to be fully described. There is a need to compare the biomechanical properties of efficacy of plate fixation with or without locking screws for surgery of two-part proximal humerus fractures. Multiple-plane locking plate and cloverleaf plate designs were tested to determine their ability to maintain fixation on the humeral head. METHODS: Eight matched pairs of cadaveric shoulders with 7-millimeter osteotomy defects at the surgical neck simulating two-part fractures of the proximal humerus were loaded to failure in thirty degrees of glenohumeral abduction. One side was repaired with a proximal humerus locking plate and the other with a cloverleaf plate. The rotator cuff musculature was then loaded via a servo-hydraulic testing machine under displacement control to simulate the deforming forces present in vivo. FINDINGS: The average maximum load to failure was greater in proximal humerus locking plates than in cloverleaf plates (876 versus 712; P=0.04). INTERPRETATION: In the cadaveric, two-part proximal humerus fracture model that was created, the locking plate displayed significantly greater holding power of the humeral head. Clinical relevance is unproven but may be manifested in vivo as improved early range of motion exercises and functional outcome.

Aged↗

Square-lashing technique in segmental spinal instrumentation: a biomechanical study.

Sublaminar wires have been used for many years for segmental spinal instrumentation in scoliosis surgery. More recently, stainless steel wires have been replaced by titanium cables. However, in rigid scoliotic curves, sublaminar wires or simple cables can either brake or pull out. The square-lashing technique was devised to avoid complications such as cable breakage or lamina cutout. The purpose of the study was therefore to test biomechanically the pull out and failure mode of simple sublaminar constructs versus the square-lashing technique. Individual vertebrae were subjected to pullout testing having one of two different constructs (single loop and square lashing) using either monofilament wire or multifilament cables. Four different methods of fixation were therefore tested: single wire construct, square-lashing wiring construct, single cable construct, and square-lashing cable construct. Ultimate failure load and failure mechanism were recorded. For the single wire the construct failed 12/16 times by wire breakage with an average ultimate failure load of 793 N. For the square-lashing wire the construct failed with pedicle fracture in 14/16, one bilateral lamina fracture, and one wire breakage. Ultimate failure load average was 1,239 N For the single cable the construct failed 12/16 times due to cable breakage (average force 1,162 N). 10/12 of these breakages were where the cable looped over the rod. For the square-lashing cable all of these constructs (16/16) failed by fracture of the pedicle with an average ultimate failure load of 1,388 N. The square-lashing construct had a higher pullout strength than the single loop and almost no cutting out from the lamina. The square-lashing technique with cables may therefore represent a new advance in segmental spinal instrumentation.

Absorptiometry, Photon↗

Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study.

This study is an attempt to describe a new technique for anterior transarticular screw fixation of the atlantoaxial joints, and to compare the stability of this construct to posterior transarticular screw fixation with and without laminar cerclage wiring. Nine human cadaveric specimens were included in this study. The C1-C2 motion segment was instrumented using either anterior transarticular screws (group 1), posterior transarticular screws alone (group 2), or posterior screws with interlaminar cerclage wires (group 3). Using an unconstrained mechanical testing machine, the specimens were tested in rotation, lateral bending, and flexion-extension using nondestructive loads of +/-2 N m. The specimens were also tested in translation using nondestructive loads of +/-100 N. All values for the three groups with regards to anterior-posterior displacement, rotation, and lateral bending were similar as determined using a Kruskal-Wallis rank sum test with a significance level of p<0.05. The only significant difference was registered in flexion-extension where the cerclage wire added some strength to the construct. Anterior transarticular screw fixation of the atlantoaxial spine has several advantages over posterior fixation techniques, and is as stable as posterior transarticular fixation in all clinically significant planes of motion. The addition of posterior interlaminar cerclage wiring further improves resistance to flexion-extension forces. Anterior transarticular screw fixation of the atlantoaxial joint is a useful technique for achieving C1-C2 stabilization.

Adult↗

Reconstructive procedure for unstable radial-sided triangular fibrocartilage complex avulsions.

PURPOSE: Radial-sided avulsions of the triangular fibrocartilage complex (TFCC) (Palmer 1D) with distal radioulnar joint (DRUJ) instability remain a challenging pathology to treat. We tested an intra-articular reconstruction that addresses unstable radial-sided TFCC avulsions. METHODS: Ten preserved, dissected, cadaveric forearm specimens with intact TFCC and without ulnar-positive variance had biomechanical testing using a hydraulic testing device. The measurement of total displacement of the ulna relative to the radius was performed with an applied load ranging from 20 N in a volar direction to 20 N in a dorsal direction. Specimens were tested sequentially with intact TFCC, with surgically induced Palmer 1D lesions, and after reconstruction of the TFCC. All tests were performed at neutral, maximal pronation, and maximal supination. RESULTS: The mean total displacements of the DRUJ of the specimens at neutral rotation were as follows: 4.1 +/- 0.4 mm for the intact specimens compared with 11.8 +/- 0.8 mm after creation of the tear and 3.9 +/- 0.7 mm for the reconstructed specimens. In maximal pronation the mean total displacements were as follows: 2.4 +/- 0.3 mm intact versus 4.9 +/- 0.7 mm for torn and 2.1 +/- 0.3 mm after reconstruction. In maximal supination the mean total displacements were as follows: 1.4 +/- 0.2 mm intact versus 5.7 +/- 1.3 mm for torn and 1.0 +/- 0.1 mm after reconstruction. All specimens obtained the preoperative pronation and supination motion after the reconstruction. CONCLUSIONS: Current procedures are unable to restore DRUJ stability without a significant limitation of pronation and supination. This intra-articular reconstruction of radial-sided TFCC avulsions succeeded in restoring baseline stability to the DRUJ without interfering with pronation/supination.

Biomechanical Phenomena↗

Effects of osteogenic protein-1 on distraction osteogenesis in rabbits.

In this study we tested the effect of locally applied osteogenic protein 1 (OP-1) on distraction osteogenesis in rabbits. Seven days after tibial osteotomy, distraction was started at a rate of 0.25 mm per 12 h for 3 weeks. At the end of the distraction period, OP-1 was injected at the site of osteotomy. Four different dosages were tested (0, 80, 800, or 2000 microg; eight rabbits per dose group). Rabbits were sacrificed 3 weeks later, and histologic, densitometric, and biomechanical parameters were assessed. No significant differences were found between groups for any parameter. To explain why this approach was only modestly successful, the expression of BMP receptor protein in the newly formed tissue was analyzed by immunohistochemistry. Strong expression of BMP receptor IA, IB, and II was found during the early distraction phase, but not during later stages of the process. Thus, it appears that the lack of receptor protein in the target tissue impairs the effect of OP-1 given at the end of the distraction period. Possibly, OP-1 could be more useful when applied early in the distraction phase.

Animals↗