Measurement accuracy and cerenkov removal for high performance, high spatial resolution scintillation dosimetry.

With highly conformal radiation therapy techniques such as intensity-modulated radiation therapy, radiosurgery, and tomotherapy becoming more common in clinical practice, the use of these narrow beams requires a higher level of precision in quality assurance and dosimetry. Plastic scintillators with their water equivalence, energy independence, and dose rate linearity have been shown to possess excellent qualities that suit the most complex and demanding radiation therapy treatment plans. The primary disadvantage of plastic scintillators is the presence of Cerenkov radiation generated in the light guide, which results in an undesired stem effect. Several techniques have been proposed to minimize this effect. In this study, we compared three such techniques-background subtraction, simple filtering, and chromatic removal-in terms of reproducibility and dose accuracy as gauges of their ability to remove the Cerenkov stem effect from the dose signal. The dosimeter used in this study comprised a 6-mm(3) plastic scintillating fiber probe, an optical fiber, and a color charge-coupled device camera. The whole system was shown to be linear and the total light collected by the camera was reproducible to within 0.31% for 5-s integration time. Background subtraction and chromatic removal were both found to be suitable for precise dose evaluation, with average absolute dose discrepancies of 0.52% and 0.67%, respectively, from ion chamber values. Background subtraction required two optical fibers, but chromatic removal used only one, thereby preventing possible measurement artifacts when a strong dose gradient was perpendicular to the optical fiber. Our findings showed that a plastic scintillation dosimeter could be made free of the effect of Cerenkov radiation.

Artifacts↗

Octree indexing of DICOM images for voxel number reduction and improvement of Monte Carlo simulation computing efficiency.

The purpose of the present study is to introduce a compression algorithm for the CT (computed tomography) data used in Monte Carlo simulations. Performing simulations on the CT data implies large computational costs as well as large memory requirements since the number of voxels in such data reaches typically into hundreds of millions voxels. CT data, however, contain homogeneous regions which could be regrouped to form larger voxels without affecting the simulation's accuracy. Based on this property we propose a compression algorithm based on octrees: in homogeneous regions the algorithm replaces groups of voxels with a smaller number of larger voxels. This reduces the number of voxels while keeping the critical high-density gradient area. Results obtained using the present algorithm on both phantom and clinical data show that compression rates up to 75% are possible without losing the dosimetric accuracy of the simulation.

Algorithms↗

Surface preparation and coupling in plastic scintillator dosimetry.

One way to improve the performance of scintillation dosimeters is to increase the light-collection efficiency at the coupling interfaces of the detector system. We performed a detailed study of surface preparation of scintillating fibers and their coupling with clear optical fibers to minimize light loss and increase the amount of light collected. We analyzed fiber-surface polishing with aluminum oxide sheets, coating fibers with magnesium oxide, and the use of eight different coupling agents (air, three optical gels, an optical curing agent, ultraviolet light, cyanoacrylate glue, and acetone). We prepared 10 scintillating fiber and clear optical fiber light guide samples to test different coupling methods. To test the coupling, we first cut both the scintillating fiber and the clear optical fiber. Then, we cleaned and polished both ends of both fibers. Finally, we coupled the scintillating fiber with the clear optical fiber in either a polyethylene jacket or a V-grooved support depending on the coupling agent used. To produce more light, we used an ultraviolet lamp to stimulate scintillation. A typical series of similar couplings showed a standard deviation in light-collection efficiency of 10%. This can be explained by differences in the surface preparation quality and alignment of the scintillating fiber with the clear optical fiber. Absence of surface polishing reduced the light collection by approximately 40%, and application of magnesium oxide on the proximal end of the scintillating fiber increased the amount of light collected from the optical fiber by approximately 39%. Of the coupling agents, we obtained the best results using one of the optical gels. Because a large amount of the light produced inside a scintillator is usually lost, better light-collection efficiency will result in improved sensitivity.

Artifacts↗

Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators.

Scintillation dosimetry is a promising avenue for evaluating dose patterns delivered by intensity-modulated radiation therapy plans or for the small fields involved in stereotactic radiosurgery. However, the increase in signal has been the goal for many authors. In this paper, a comparison is made between plastic scintillating fibers and plastic scintillator. The collection of scintillation light was measured experimentally for four commercial models of scintillating fibers (BCF-12, BCF-60, SCSF-78, SCSF-3HF) and two models of plastic scintillators (BC-400, BC-408). The emission spectra of all six scintillators were obtained by using an optical spectrum analyzer and they were compared with theoretical behavior. For scintillation in the blue region, the signal intensity of a singly clad scintillating fiber (BCF-12) was 120% of that of the plastic scintillator (BC-400). For the multiclad fiber (SCSF-78), the signal reached 144% of that of the plastic scintillator. The intensity of the green scintillating fibers was lower than that of the plastic scintillator: 47% for the singly clad fiber (BCF-60) and 77% for the multiclad fiber (SCSF-3HF). The collected light was studied as a function of the scintillator length and radius for a cylindrical probe. We found that symmetric detectors with nearly the same spatial resolution in each direction (2 mm in diameter by 3 mm in length) could be made with a signal equivalent to those of the more commonly used asymmetric scintillators. With augmentation of the signal-to-noise ratio in consideration, this paper presents a series of comparisons that should provide insight into selection of a scintillator type and volume for development of a medical dosimeter.

Computer-Aided Design↗

The robustness of dose distributions to displacement and migration of 125I permanent seed implants over a wide range of seed number, activity, and designs.

PURPOSE: To investigate the robustness of permanent prostate implant dosimetry for various (125)I seed activities and various seed models. The dosimetric impact of seed misplacement and seed migration (seed loss) is also taken into account using various standard dose indices. METHODS AND MATERIALS: A dose-based inverse planning algorithm is used for automated dosimetric plan creation (45-60 s per plan) and provides an unbiased way to compare the robustness of various optimal dosimetric plans. Seed misplacement and seed migration are simulated by way of Monte Carlo, based on the measured displacement distributions from clinical postimplant cases. Plans were generated for seed activities between 0.2 and 1.4 mCi (0.25 to 1.78 U) and for 11 different seed models. RESULTS: The numbers of seeds and needles are shown to decrease rapidly for a seed activity between 0.3 mCi and 0.6 mCi (0.38 and 0.76 U). The loss in V100, from 100%, because of seed misplacement is below 10% for an apparent activity ranging from 0.2 to 0.9 mCi (0.25 to 1.14 U). A minimum degradation in V100 is observed around 0.6-0.7 mCi (0.76-0.89 U). D90 increases from 150 to 170 Gy between 0.3 and 0.7 mCi (0.38 and 0.89 U) and decreases afterward to fall below 140 Gy at higher activity. V200 and D10 to the target volume both show an increase in hot spots up to 0.7 mCi, and then decrease linearly at higher activities for all seed models. V200 and D10 to the urethra remain about constant for all seed activities up to 0.8 mCi (1.02 U), at which point they start to decrease. All seed models follow this general trend. CONCLUSIONS: Plans were shown to be robust to misplacement and migration of seeds over a wide range of seed activity and for various seed models. With a properly tuned inverse planning algorithm able to ensure the dose coverage and protection for the organs at risk in the presence of placement errors (displacement and migration), the choice of a preferred seed activity, in a range up to about 0.7 mCi (0.89 U), is open. The upper part of this range offers the opportunity to significantly reduce the number of seeds and needles, thus reducing surgical trauma to the patient, saving time in an operating room planning setting, and reducing the cost of a permanent prostate implant procedure.

Algorithms↗

Automatic post-implant needle reconstruction algorithm to characterize and improve implant robustness analyses.

Post-implant analysis in permanent implant brachytherapy is an important process that provides a feedback on treatment quality. Random seed movements, edema, and needle related factors contribute to deteriorate dose coverage. For a complete study of these movements, it is important to reconstruct the post-implant seeds clusters but, up to now, this task was only possible via a long and difficult manual process. To facilitate post-implant analysis a simulated annealing algorithm was developed to perform automatic reconstructions. This process is fast (30-60 s on a 1.3 GHz pentium) and has a high level of success, even with up to 5% of seed loss. Tests on 21 clinical cases show that the algorithm yields exactly the same results as manual reconstructions. A realistic simulation tool was used to generate 58 synthetic post-implant data, in which cases the exact configuration was known. Even if some errors were found, pertinent information was extracted. For medium seed density [corresponding to seeds of 0.6 mCi (0.762 U)], 97% of seeds are matched with their correct needle and 89% are matched with their correct planned position. This method provides pertinent information that can be used to understand inhomogenous dose coverage in specific prostate quadrants; to make realistic post-implant simulations or to identify seeds belonging to a needle loaded with different seed types or activity.

Algorithms↗