PubMed Health⌕ Search

Biomedical subjects

Lourdes Llorente

Publications and source records attributed to Lourdes Llorente.

6 recordsLinked to original sources

Optical aberrations in the mouse eye.

PURPOSE: The mouse eye is a widely used model for retinal disease and has potential to become a model for myopia. Studies of retinal disease will benefit from imaging the fundus in vivo. Experimental models of myopia often rely on manipulation of the visual experience. In both cases, knowledge of the optical quality of the eye, and in particular, the retinal image quality degradation imposed by the ocular aberrations is essential. In this study, we measured the ocular aberrations in the wild type mouse. METHODS: Twelve eyes from six four-week old black C57BL/6 wild type mice were studied. Measurements were done on awake animals, one being also measured under anesthesia for comparative purposes. Ocular aberrations were measured using a custom-built Hartmann-Shack system (using 680-nm illumination). Wave aberrations are reported up to fourth order Zernike polynomials. Spherical equivalent and astigmatism were obtained from the 2nd order Zernike terms. Modulation Transfer Functions (MTF) were estimated for the best focus, and through-focus, to estimate depth-of-focus. All reported data were for 1.5-mm pupils. RESULTS: Hartmann-Shack refractions were consistently hyperopic (10.12+/-1.41 D, mean and standard deviation) and astigmatism was present in many of the eyes (3.64+/-3.70 D, on average). Spherical aberration was positive in all eyes (0.15+/-0.07 microm) and coma terms RMS were significantly high compared to other Zernike terms (0.10+/-0.03 microm). MTFs estimated from wave aberrations show a modulation of 0.4 at 2c/deg, for best focus (and 0.15 without cancelling the measured defocus). For that spatial frequency, depth-of-focus estimated from through-focus modulation data using the Rayleigh criterion was 6D. Aberrations in the eye of one anesthetized mouse were higher than in the same eye of the awake animal. CONCLUSIONS: Hyperopic refractions in the mouse eye are consistent with previous retinoscopic data. The optics of the mouse eye is far from being diffraction-limited at 1.5-mm pupil, with significant amounts of spherical aberration and coma. However, estimates of MTFs from wave aberrations are higher than previously reported using a double-pass technique, resulting in smaller depth-of-field predictions. Despite the large degradation imposed by the aberrations these are lower than the amount of aberrations typically corrected by available correction techniques (i.e., adaptive optics). On the other hand, aberrations do not seem to be the limiting factor in the mouse spatial resolution. While the mouse optics are much more degraded than in other experimental models of myopia, its tolerance to large amounts of defocus does not seem to be determined entirely by the ocular aberrations.

Animals↗

Myopic versus hyperopic eyes: axial length, corneal shape and optical aberrations.

This study investigated differences in geometrical properties and optical aberrations between a group of hyperopes and myopes (age-matched 30.3+/-5.2 and 30.5+/-3.8 years old, respectively, and with similar absolute refractive error 3.0+/-2.0 and -3.3+/-2.0, respectively). Axial length (AL) was measured by means of optical biometry, and corneal apical radius of curvature (CR) and asphericity (Q) were measured by fitting corneal topography data to biconic surfaces. Corneal aberrations were estimated from corneal topography by means of virtual ray tracing, and total aberrations were measured using a laser ray tracing technique. Internal aberrations were estimated by subtracting corneal from total aberrations. AL was significantly higher in myopes than in hyperopes and AL/CR was highly correlated with spherical equivalent. Hyperopic eyes tended to have higher (less negative) Q and higher total and corneal spherical aberration than myopic eyes. RMS for third-order aberrations was also significantly higher for the hyperopic eyes. Internal aberrations were not significantly different between the myopic and hyperopic groups, although internal spherical aberration showed a significant age-related shift toward less negative values in the hyperopic group. For these age and refraction ranges, our cross-sectional results do not support evidence of relationships between emmetropization and ocular aberrations. Our results may be indicative of presbyopic changes occurring earlier in hyperopes than in myopes.

Adult↗

Aberrations of the human eye in visible and near infrared illumination.

PURPOSE: In most current aberrometers, near infrared light is used to measure ocular aberrations, whereas in some applications, optical aberration data in the visible range are required. We compared optical aberration measurements using infrared (787 nm) and visible light (543 nm) in a heterogeneous group of subjects to assess whether aberrations are similar in both wavelengths and to estimate experimentally the ocular chromatic focus shift. METHODS: Ocular aberrations were measured in near infrared and visible light using two different laboratory-developed systems: laser ray tracing (LRT) and Shack-Hartmann. Measurements were conducted on 36 eyes (25 and 11 eyes, respectively), within a wide range of ages (20 to 71 years), refractive errors (-6.00 to +16.50), and optical quality (root mean square wavefront error, excluding defocus, from 0.40 to 9.89 microm). In both systems, wave aberrations were computed from the ray aberrations by modal fitting to a Zernike polynomial base (up to seventh order in laser ray tracing and sixth order in Shack-Hartmann). We compared the Zernike coefficients and the root mean square wavefront error corresponding to different terms between infrared and green illumination. RESULTS: A Student's t-test performed on the Zernike coefficients indicates that defocus was significantly different in all of the subjects but one. Average focus shift found between 787 nm and 543 nm was 0.72 D. A very small percentage of the remaining coefficients was found to be significantly different: 4.7% of the 825 coefficients (25 eyes with 33 terms) for laser ray tracing and 18.2% of the 275 coefficients (11 eyes with 25 terms) for Shack-Hartmann. Astigmatism was statistically different in 8.3% of the eyes, root mean square wavefront error for third-order aberrations in 16.6%, and spherical aberration (Z4(0)) in 11.1%. CONCLUSIONS: Aerial images captured using infrared and green light showed noticeable differences. Apart from defocus, this did not affect centroid computations because within the variability of the techniques, estimates of aberrations with infrared were equivalent to those measured with green. In normal eyes, the Longitudinal Chromatic Aberration of the Indiana Chromatic Eye Model can predict the defocus term changes measured experimentally, although the intersubject variability could not be neglected. The largest deviations from the prediction were found on an aphakic eye and on the oldest subject.

Adult↗

On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry.

PURPOSE: Our aim was to obtain a complete description of the interactions of rigid gas permeable (RGP) contact lenses with the optics of normal eyes. METHODS: We measured total and anterior-surface aberrations in four subjects, who were all long-term RGP contact lens wearers. The anterior-surface wave aberration was obtained from videokeratographic elevation maps, and ocular wave aberration was measured with a laser ray-tracing technique. Measurements were performed with and without their own spherical contact lenses. RESULTS: With this methodology, we evaluated the optical performance with RGP lenses compared with the natural optics. We estimated the contribution of the anterior surface of the contact lens, the internal ocular optics, flexure, and the tear lens aberrations to the optical performance of eyes wearing RGP contact lenses. We found that in three of four subjects, the contact lens significantly improved the natural optics of the eye. For the subject with higher dominance of corneal aberrations, root mean square (second-order and higher) decreased from 1.36 microm to 0.46 microm. Third- and higher-order aberrations decreased from 0.77 microm to 0.39 microm. The internal optics and lens flexure imposed limits on aberration compensation. Spherical RGP contact lenses did not produce spherical aberration potentially due to a compensatory role of the tear lens. CONCLUSIONS: Aberration measurements are useful to understand the fitting of contact lenses and the interaction with tear, cornea, and internal optics of the eye. Aberrometry can help to choose the best standard RGP lens parameters to improve the optics of individual eyes.

Adolescent↗

Ocular aberrations with ray tracing and Shack-Hartmann wave-front sensors: does polarization play a role?

Ocular aberrations were measured in 71 eyes by using two reflectometric aberrometers, employing laser ray tracing (LRT) (60 eyes) and a Shack-Hartmann wave-front sensor (S-H) (11 eyes). In both techniques a point source is imaged on the retina (through different pupil positions in the LRT or a single position in the S-H). The aberrations are estimated by measuring the deviations of the retinal spot from the reference as the pupil is sampled (in LRT) or the deviations of a wave front as it emerges from the eye by means of a lenslet array (in the S-H). In this paper we studied the effect of different polarization configurations in the aberration measurements, including linearly polarized light and circularly polarized light in the illuminating channel and sampling light in the crossed or parallel orientations. In addition, completely depolarized light in the imaging channel was obtained from retinal lipofuscin autofluorescence. The intensity distribution of the retinal spots as a function of entry (for LRT) or exit pupil (for S-H) depends on the polarization configuration. These intensity patterns show bright corners and a dark area at the pupil center for crossed polarization, an approximately Gaussian distribution for parallel polarization and a homogeneous distribution for the autofluorescence case. However, the measured aberrations are independent of the polarization states. These results indicate that the differences in retardation across the pupil imposed by corneal birefringence do not produce significant phase delays compared with those produced by aberrations, at least within the accuracy of these techniques. In addition, differences in the recorded aerial images due to changes in polarization do not affect the aberration measurements in these reflectometric aberrometers.

Adult↗

Total and corneal optical aberrations induced by laser in situ keratomileusis for hyperopia.

PURPOSE: To evaluate changes induced by standard laser in situ keratomileusis (LASIK) for hyperopia on total and corneal optical quality. METHODS: Total and corneal aberrations were measured before and after standard hyperopic LASIK in 13 eyes (preoperative spherical equivalent refractive error +3.17 +/- 1.10 D). The Chiron Technolas 217C laser with PlanoScan was used. Total aberrations (measured using laser ray tracing) and corneal aberrations (estimated from a videokeratoscope) were described using Zernike terms. Root-mean-square wavefront error for both total and corneal aberrations, and through-focus Strehl ratio for the point spread function of the whole eye were used to assess optical changes induced by surgery. RESULTS: Third and higher order aberrations increased significantly after hyperopic LASIK (by a factor of 2.20 for total and 1.78 for corneal aberrations, for a 6.5-mm pupil). Spherical aberration changed to negative values (corneal average decreased by -0.85 +/- 0.48 microm and total average by -0.70 +/- 0.30 microm). Best Strehl ratio for the whole eye decreased by a factor of 1.84. Hyperopic LASIK induced larger changes than myopic LASIK, compared to an equivalent group of myopic eyes from a previous study. Induced corneal spherical aberration was six times larger after hyperopic LASIK, for a similar range of correction, and of opposite sign. As with myopic LASIK, changes in internal spherical aberration are of opposite sign to those induced on the corneal anterior surface. CONCLUSIONS: Hyperopic LASIK induced significant amounts of aberrations. The largest increase occurred in spherical aberration, which showed a shift (toward negative values) of opposite sign; increase was greater than for myopic LASIK.

Adult↗